• Integrating Sphere Spectroradiometer System for LED

    LPCE-2(LMS-8000) is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 127-1997 and IES LM 79-08 standards, it recommends using an array spectroradiometer with integrating sphere and photometer head to test SSL products. LISUN GROUP developed LPCE-2 test system for LED products. The LMS-8000S CCD Spectroradiometer…

  • Rotation Luminaire Goniophotometer

    LSG-1800/LSG-1700/LSG-1600 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700/LSG-1600, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on. Rotation Luminaire Goniophotometer Specification:…

  • Integrated Function Tester for Inductance Ballast

    • Measure input parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components. V range: 10.0~300.0V, A range: 0.010~2.000A, F range: 45~65Hz • Measure output parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components Lamp voltage range: 10.0~450.0V, Lamp current range: 0.010~2.000A • Accuracy: ± (0.4% reading+0.1% range+1 digit) • Can test every kind of curve, print both data & curve • Communication interface available…

  • Fluorescent Lamp Asymmetric Pulse Tester

    UI2002C is designed according to the latest update in IEC 61347-2-3 about the test requirements for local rectifying effects on tubes. It imitates the condition when tube is under local rectifying status and tests the abnormal protection function of ballast by adopting fluorescent lamp asymmetry pulse test method with 3 windows for displaying rectified voltage, rectified current, and rectified power. It is easy for operation and with high test accuracy. • Measure lamp…

  • Goniophotometer with Rotating Mirror

    LSG-2000 Goniophotometer with Rotating Mirror (Moving Mirror Goniophotometer) completely meet LM-79 Clause 9.3.1. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal…

  • New Design 3m Electric Integrating Sphere

    • It has all functions of IS-*MA Integrating Sphere with Holder Base. • Lisun engineers add the infrared anti-pinch device (the video please come to the “video” tab) and the cross laser positioning device in the integrating sphere. • Please refer to article The New Design 3m Electric Integrating Sphere for more information. According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED…

  • Compact Goniophotometer

    The compact goniophotometer of LSG-1200A is used to measure the luminous intensity distribution curve, intensity data, spread angle and other parameters for Chip LED, LED Module, LED Spotlight and all other light which beam angle is no more than 180 degree. Option Function: The LSG-1200A can work with a Digital Power Meter (LS2012 DC & AC Power Meter or LS2010 Harmonic Analyzer) and LSP-500VA AC Power Source. Specification: • Meets the requirements of IEC, CIE and…

  • High Precision Rotation Luminaire Goniospectroradiometer

    LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution,…

  • Ball Pressure Test Device

    Made up by the related item according to IEC60695, IEC884-1, GB/T5169.21-2006, GB4706.1-2005, GB2099.1-2008, etc. • R = 2.5mm Pressure: 20N • Base with thermocouple hole • Material: 304 stainless steel

  • Current Transformer Tester

    Characteristics: • Full-featured, can not only satisfy various CT (eg: protection, measurement and TP category) but also PT type electromagnetic unit for its excitation characteristics (ie voltage current characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio deviation, angle deviation and other test requirements. • Automatically gives the knee point voltage / current, 10% (5%) error curve, accurate limit factor (ALF), instrument security factor (FS), secondary time constant (Ts), remanence coefficient (Kr),…

  • Standard Test Finger

    It with Protection against electric shock device. It according to IEC60335, IEC60884, IEC61032, IEC60529, IEC60065, IEC60035, IEC60950, EN60529, EN60950, GB4706, GB7000, GB9706, UL507, VDE0470, etc.

  • MOS Transistor Selector

    • Measure parameters: Open voltage UGS (th), internal resistance RDS, Transconductance gm, Withstand voltage V (BR) DS • Test range: UGS (th) 0.1-9.9V; RDS 0.001-9.999Ω gm; 0.10-10.00s; V (BR) DS 50-650V • Test current range: 0.1A-5A adjustable, comply with different working situation • Automatic selecting, out of limit alarming, advance the work efficiency • The technique of testing RDS under the big-current, is advanced technique