• Absorbing Clamp

    Specification:  • EMI Receiver equipped with absorbing clamp can indirectly test radiated interference power of household electrical appliance, power tool and similar electrical appliance with frequency from 30~300MHz.  

  • Artificial Network

    Specification:  EMI Receiver equipped with artificial network can test interference voltage of mains terminals.

  • Pulse Start Generator for High Pressure Sodium Lamp

    The start-up test of the special lights pulse start generator is for lighting class industry such as high pressure sodium, it is according to IEC60662: 2011 and GB/T13259-2005 standard requirements. Specification: Wave Generator Superimposed on the sine wave pulse discharge waveform Open Circuit Output Voltage 0.1 ~ 3kv Burst Period 20ms Polarity Positive polarity Phase Shift Sync: 0° to 360° and the step value is 1° Output Impedance 40Ω Coupling…

  • Goniophotometer with Rotating Mirror

    LSG-2000 Goniophotometer with Rotating Mirror (Moving Mirror Goniophotometer) completely meet LM-79 Clause 9.3.1. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal…

  • New Design 3m Electric Integrating Sphere

    • It has all functions of IS-*MA Integrating Sphere with Holder Base. • Lisun engineers add the infrared anti-pinch device (the video please come to the “video” tab) and the cross laser positioning device in the integrating sphere. • Please refer to article The New Design 3m Electric Integrating Sphere for more information. According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED…

  • Ring Wave Generator

    Ring Wave Generator is the test equipment in conformity to IEC (the International Electro technical Commission) standard IEC61000-4-12, EN61000-4-12, ANSI-C62-41 and GB/T17626.12. This instrument is used for the simulative electrical network, the power supply of the reactive load and the control line switch, as well as sensing the ring wave of the low voltage cables terminal equipment caused by the disconnection of the power circuit, fault and insulation breakdown or…

  • Voltage Dips and Interruptions Generator

    The voltage dip and interruptions generator is specially designed according to the characteristics and requirements of EMS measurement under a sudden reduction or interruption of the voltage at a point, CSS61000-11/ CSS61000-11T used a big LCD in both English and Chinese operating interface. They have more fine performance such as high reliability, convenient operation, and full meet the standard requirements of IEC 61000-4-11, EN 61000-4-11 and GB/T17626.11 Specifications: Product Model…

  • High Precision Rotation Luminaire Goniospectroradiometer

    LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution,…

  • Ball Pressure Test Device

    Made up by the related item according to IEC60695, IEC884-1, GB/T5169.21-2006, GB4706.1-2005, GB2099.1-2008, etc. • R = 2.5mm Pressure: 20N • Base with thermocouple hole • Material: 304 stainless steel

  • Current Transformer Tester

    Characteristics: • Full-featured, can not only satisfy various CT (eg: protection, measurement and TP category) but also PT type electromagnetic unit for its excitation characteristics (ie voltage current characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio deviation, angle deviation and other test requirements. • Automatically gives the knee point voltage / current, 10% (5%) error curve, accurate limit factor (ALF), instrument security factor (FS), secondary time constant (Ts), remanence coefficient (Kr),…

  • Standard Test Finger

    It with Protection against electric shock device. It according to IEC60335, IEC60884, IEC61032, IEC60529, IEC60065, IEC60035, IEC60950, EN60529, EN60950, GB4706, GB7000, GB9706, UL507, VDE0470, etc.

  • MOS Transistor Selector

    • Measure parameters: Open voltage UGS (th), internal resistance RDS, Transconductance gm, Withstand voltage V (BR) DS • Test range: UGS (th) 0.1-9.9V; RDS 0.001-9.999Ω gm; 0.10-10.00s; V (BR) DS 50-650V • Test current range: 0.1A-5A adjustable, comply with different working situation • Automatic selecting, out of limit alarming, advance the work efficiency • The technique of testing RDS under the big-current, is advanced technique

123456 Next > >> Page 1 / 6