Composite Salt Spray Test Chamber

Product No:

Leave a Message

=

Composite Salt Spray Test Chamber

Leave a Message

=
Product Description

YWX/Q-150X series Composite Salt Spray Test Machine do measurement through simulating conditions that are more commonly encountered in the natural environment such as  salt spray, hot air drying, humidity, low temperature combined and loop in any order. It is widely used to test items used in drastically changing environments, such as automobile parts, aviation equipment, building materials, coating, electric and electrical machinery so on.

Standard:
GB/T 2423.18 “Environmental testing – Part 2: Test methods – Test Kb: Salt mist, cyclic (sodium chloride solution)”
IEC 60068-2-52 “Enrironmental testing -Part 2-52: Tests – Test Kb: Salt mist, cyclic (sodium chloride solution)”
ISO 3769 “Metallic coatings – Acetic acid salt spray test (ASS test)”
VDA233-102 “Cyclic corrosion testing of materials & components in automotive construction”
GMW 14872 “Cyclic Corrosion Laboratory Test”
TCSAE 71 “Cyclic corrosion test methods of automotive assemblies and materials”
VCS 1027 1449 “Accelerated Cyclic Corrosion Test”
PV 1210 “Corrosion Test”

Specififation:

LISUN ModelYWX/Q-250XYWX/Q-750XYWX/Q-010XYWX/Q-016XYWX/Q-020X
Working room size900*600*5001100*750*5001200*800*5001600*1000*6002000*1000*600
External dimensions2160*1100*13002360*1250*13002460*1300*13502860*1500*14503260*1500*1450
Capacity270L412L480L960L1200L
Solution tank volume25L30L30L35L40L
Pure water tank volume30L35L35L40L50L
Working powerThree Phase AC 380V/50HZ (60Hz is optional)
10.0KW12.0KW12.5KW16.0KW18.5KW
Sample space available700*450*250900*600*3001000*600*3001400*800*3501800*800*350
Opening MethodManually controlStainless steel air spring supportCylinder support
Working environmental temperature requirementsThe ambient temperature is 5℃~30℃. Ventilation is recommended. When the temperature exceeds 30℃, it is recommended to adjust the room temperature through appropriate methods.
Working environment humidity requirementsEnvironmental humidity below 85%Rh
The temperature range of the salt spray chamber15℃~65℃
The temperature range of saturated barrelRT (room temperature) ~ 70 ℃
Relative humidity of the salt spray chamber30%-98%RH (± 3%, adjustable, refer to the temperature and humidity corresponding chart)
Temperature performanceTemperature uniformity: ≤2 ℃ Temperature volatility: ≤ ± 1 ℃
Salt spray deposition rate1-2ml/80cm²/h
Test methodsProgrammable spray, moist heat, dry, standard climate
Test conditionsA. Saline spray test: NSS * test: 35 ℃ ± 2 ℃ * Saturated air barrel: 47 ℃ ± 2 ℃
B. humidity and heat test: 1. Test temperature range: 20 ℃ -60 ℃. 2. Test humidity range: 60%RH ~ 98%RH can be adjusted.
C. Dry test: 1. Test temperature range: 20 ℃ ~ 60 ℃. 2. Test humidity range: 30%RH ~ 60%RH can be adjusted.
Standard accessories1 set of V -type/O -type storage racks, 1 glass nozzle, 2 bottles of sodium sodium (500g/bottle), 1 plastic rust barrel (5L )

Optional suggestions: When using LISUN YWX/Q-010X Composite Salt Spray Test Machine, it is necessary to choose a LISUN LS-EU800W2-55L air compressor (power 800W*2, capacity 55L, speed 1380r/min, pressure 0.7Mpa, flow 120L/m in, 220~240V/50Hz) or LS-US800W2-55L air compressor (power 800W*2, capacity 55L, speed 1380r/min, pressure 0.7Mpa, flow 120L/min, 110~120V/60Hz).

LS EU800W2 55L Air Compressor

LS-EU800W2-55L Air Compressor

Test Principle:
Composite Salt Spray Test Machine is composed of the cyclic corrosion test of the spray process, the damp and heat process, and the standing and drying process. The following are the schematic diagrams of these three processes:

1. Spray process
The system consists of salt water tank, pneumatic system, salt water storage tank, spray tower, nozzle, etc. The salt solution flows from the outside to the test chamber by using the natural drop, and the salt solution is atomized by compressed air through the spray nozzle.

2 2

Figure 1 Schematic diagram of the spray process

2. Damp heat test
The damp heat test system is composed of steam generator, blast, water circuit, condensation device, etc. After the salt spray test, the machine will set up a defogging program to discharge the salt spray out of the test room as soon as possible; Then the water evaporator will output the appropriate temperature and humidity according to the temperature and humidity set by the controller. Generally speaking, the humidity will be more accurately calibrated and constant after the temperature is stable. The temperature and humidity parameters of the damp heat test are as follows: Temperature: 30℃—60℃; humidity: 80%RH—98%RH.

1 5

Figure 2 Schematic diagram of damp heat test

3. Drying process
Standing and drying system adds drying blower, heating wire, air filter and other devices on the basis of damp heat system, if need to simulate standard atmospheric pressure environment test (temperature 23℃±2℃, humidity 45%~55% RH). Firstly, quickly remove the damp and heat test environment in the previous section by setting a defogging program to create a relatively clean test environment, and then the humidifier or dehumidification system works in coordination under the controller to produce an environment that meets the test requirements. The temperature and humidity parameters of the drying test are as follows: temperature: 20℃-60℃; humidity: 30%~60%RH (corresponding to the appropriate temperature point).

 

3 3

Figure 3 Principle diagram of drying process