Online Chat

+8615317905991

GLE-20_AL1

Face Masks Particulate Filtration Efficiency PFE Tester

Product No:

Leave a Message

=
GLE-20_AL1

Face Masks Particulate Filtration Efficiency PFE Tester

Leave a Message

=
Product Description

GLE-20 is an oil-salt two-in-one Face Masks Particulate Filtration Efficiency PFE Tester. It is designed ccording to ASTM F1862-17, ASTM F2299-03 (2017), ASTM F2100-2019, BS EN14683-2019, BS EN 14387-2004+A1 2008, BS EN 136-1998, BS EN 140-1999, BS EN 143-2000 +C1-A1, BS EN 149-2001+A1, etc. It is used to test the particulate filtering efficiency of daily protective masks and medical masks, and to determine the obstruction performance of ordinary fabrics and medical protective masks against a constant flow of airflow. It is widely used for medical device inspection centers, safety protection inspection centers, labor protection inspection centers, drug inspection centers, disease prevention and control centers, textile testing centers, hospitals, mask manufacturers, etc.

MASK 1 AL11 e1591865531262

Standard:
ASTM F1862 “Standard Test Method for Resistance of Medical Face Masks to Penetration by Synthetic Blood (Horizontal Projection of Fixed Volume at a Known Velocity)”
ASTM F2299 “Standard Test Method for Determining the Initial Efficiency of Materials Used in Medical Face Masks to Penetration by Particulates Using Latex Spheres”
ASTM F2100 “Standard Specification for Performance of Materials Used in Medical Face Masks”
BS EN14683 “Medical face masks. Requirements and test methods”
BS EN 14387 “Respiratory protective devices. Gas filter(s) and combined filter(s). Requirements, testing, marking”
BS EN 136 “Respiratory protective devices. Full face masks. Requirements, testing, marking”
BS EN 140 “Respiratory protective devices. Half masks and quarter masks. Requirements, testing, marking”
BS EN 143 “Respiratory protective devices. Particle filters. Requirements, testing, marking”
BS EN 149 “Respiratory protective devices. Filtering half masks to protect against particles. Requirements, testing, marking”
EN 1822-3 “High efficiency air filters (EPA, HEPA and ULPA) – Part 3: Testing flat sheet filter media”
GB 2626 “Respiratory Protective Equipment Self-Suction Filter Anti-Particle Respirator”
GB / T 32610 “Technical Specifications for Daily Protective Masks”
GB / T 19082 “Technical requirements for medical disposable protective clothing”
GB / T 19083 “Technical Requirements for Medical Protective Masks”
GB 24539 General technical requirements for protective clothing and chemical protective clothing
YY 0469 “Technical Requirements for Medical Surgical Masks”
YY / T 0969 “Standard for disposable medical masks”

Standard Requirement:
Using sodium chloride particles to detect KN filter elements, and use dioctyl phthalate or equivalent oil particles (or paraffin oil) to detect KP filter elements.
Test according to 6.3
During the test, the filtration efficiency of each sample should always meet the requirements of Table 2

Filtration efficiency

Filter element category and levelParticle detection with sodium chlorideDetection with oil particles
KN9090.0% 

Not Siut

KN9595.0%
KN10099.97%
KP90 

Not Suit

90.0%
KP9595.0%
KP10099.97%

Specification:

  1. Filtration efficiency detection flowmeter range: (10 ~ 100) L / min, accuracy level 2.5
  2. Filtration efficiency detection range: (0.001 ~999)%.
  3. Filtering efficiency sampling frequency: 1-9999 times / min can be set arbitrarily.
  4. Filtration efficiency Particulate concentration: (0.001-200) mg / m³.
  5. Differential pressure sensor range: 0 ~1000pa
  6. Counting median diameter: salt particles (0.075 ±0.02) μm, oil particles (0.185 ± 0.02) μm. Geometric standard deviation of particle size distribution: salt particles≤1.86, oil particles≤1.60. Dynamic detection range: 0.001-100 mg / m³, accuracy 1%.
  7. Test area: 100cm².
  8. Aerosol: NaCl (optionally with DOP, DEHS, paraffin oil, corn oil).
  9. Aerosol concentration: 12-20mg / m³ (Nacl), 50-200mg / m³ (DOP).
  10. The system contains two independent aerosol generators: oily and salty aerosol generators containing two particle counting sensors, one particle concentration sensor and one particle generator
  11. Power: AC220V 50Hz(120V/60Hz can be customized)

GLE-20 Characteristic:

  1. The oil and salt two-in-one test and the two sets of test hardware systems are completely independent. The test does not interfere with each other to ensure the accuracy of the oil and salt test.
  2. The aerosol generator is used to produce continuous and stable aerosol particles, which is convenient for filling the solution.
  3. A high-precision particle concentration counter (the core component of the sensor imported from the United States) is used to measure the number of aerosol particles.
  4. The whole particle anti-leakage design protects the safety of laboratory personnel.
  5. Equipped with aerosol particulate static neutralization device.
  6. Configure temperature and humidity sensor, real-time display of ambient temperature and humidity (temperature and humidity requirements: 25 ℃ ± 5 ℃, 30% RH ± 10% RH).
  7. Equipped with glass rotor flowmeter, vacuum pump and gas electromagnetic flowmeter.
  8. Control system: touch-screen computer and test software have been configured to automatically test gas concentration and filtration efficiency, save, output, query, copy and export test data, support A4 paper printing and small bill printing test results

Test Report (PDF Report and Result Receipt, can also print in English):
test report 2 2

LISUN GLE-20 Face Masks Particulate Filtration Efficiency PFE Tester – After-sales Frequently Asked Questions (FAQ)
LISUN GLE-20 Face Masks Particulate Filtration Efficiency PFE Tester were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.

en_USEN