High and Low Temperature Thermal Shock Chamber can be used in the temperature shock test and fast-changing temperature test in a wide range such as aviation, air space, electronic components and material research.

HLST-500D has two separate chambers: high temperature chamber and low temperature chamber.
HLST-500T has three separate chambers: high temperature chamber, low temperature chamber and test chamber.

معيار:
IEC 60068-2-14 (GB/T 2423.22) “Environmental testing – Part 2-14: Tests – Test N: Change of temperature”
ISO 16750-4 “Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 4: Climatic loads”
GJB 150.5A “Laboratory environmental test methods for military material – Part 5: Temperature shock test”
GB/ T10592 “Specifications for high/low temperature testing chambers”

Operation Principles:
HLST-500D: The sample is controlled by a basket and shuttles between the high temperature chamber and the low temperature chamber.
HLST-500T: The sample always stays in the test chamber during the measurement. High temperature chamber prepares high temperature air and low temperature chamber prepares low temperature air. The sample chamber will connect with high temperature chamber for high temperature test and will connect with low temperature chamber for low temperature test. Then, the air in test chamber will reach your target temperature in several minutes (“recover time”).

Main Technical Parameters:

LISUN modelHLST-100D-*HLST-250D-*HLST-500D-*HLST-100T-*HLST-250T-*HLST-500T-*
Chamber Structure(chamber type)Two-chamber TypeThree-chamber Type
Working room size(mm)450*450*500600*600*600800*800*800450*450*500600*600*600800*800*800
Basket Size(Two-chamber type)250*250*250400*400*450600*600*600///
Sample rack (standard)One layerOne layerOne layerTwo LayersTwo layersTwo layers
The corresponding range of temperature, power, and cooling methodTemperature rangeA:-20℃~150℃
PowerAbout 15KWAbout 25KWAbout 38KWAbout 20KWAbout 30KWAbout 40KW
Cooling methodWind coolingWind coolingWind coolingWind coolingWater CoolingWater Cooling
The corresponding range of temperature, power, and cooling methodTemperature rangeB:-40℃~150℃
PowerAbout 22KWAbout 32KWAbout 45KWAbout 28KWAbout 38KWAbout 45KW
Cooling methodWind coolingWind coolingWind coolingWind coolingWater coolingWater Cooling
The corresponding range of temperature, power, and cooling methodTemperature rangeC:-50℃~150℃
PowerAbout 32KWAbout 43KWAbout 48KWAbout 35KWAbout 43KWAbout 48KW
Cooling methodWind coolingWind coolingWater coolingWind coolingWater coolingWater Cooling
High and low temperature conversion time≤10S
Temperature recovery time≤5min
Temperature volatility≤±0.5℃
Temperature deviation±2℃
Temperature uniformity≤2℃
ResolutionTemperature: 1 ℃, time: 0.1min
نظام التحكمRegulatorImported color LCD touch screen
Accuracy rangeTemperature accuracy: temperature 0.1 ℃; indicator accuracy: temperature 0.1 ℃
Temperature SensorPlatinum resistance pt100Ω/ MV
Heating SystemComplete independent system, electric heating nickel chromium alloy heating device
Cooling SystemFrench “TECUMSEH”, Germany Bishel and other fully enclosed (or semi -closed) air -cooled (or water -cooled) single -stage or (fold) refrigeration compressor -level joint mode.
Circulatory systemTemperature -resistant and low noise air -conditioning motor multi -blade centrifugal wind wheel
Test chamber materialExternal materialHigh -quality carbon steel. Phosphoric acid electrostatic spray treatment/ SUS304 stainless steel sub -light line hairline treatment
Internal materialsSUS304 high -quality stainless steel plate
Insulation MaterialsPolyurethane hard bubble/fine glass fiber cotton
Insulation doorDouble high temperature aging resistant silicone rubber door seal
SecurityLeakage protection, short circuit protection, overheating protection, motor overheating protection, compressor overvoltage protection, overcurrent protection
Time set0.1~999.9 (H、M、S) adjustable
Working power3-phase 5-wire AC380V/50Hz (60Hz available)
Working temperature5℃~30℃;≤85%R.H

Note: HLST-100D-*: * you can choose three temperature intervals of A/B/C, for example: LISUN model HLST-100D-B, D represents two-chamber type, B represents the temperature range of -40 ℃ ~ 150 ° C; HLST-500T-C, T which represents the three-chamber type and C represents the impact temperature range of -50 ° C ~ 150 ° C. Special working size and shock temperature range can be customized according to customer requirements.