{"id":2333,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/goniophotometer-with-rotating-mirror\/"},"modified":"2025-06-27T10:24:48","modified_gmt":"2025-06-27T02:24:48","slug":"goniophotometer-with-rotating-mirror","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ar\/%d9%85%d9%86%d8%aa%d8%ac%d8%a7%d8%aa\/goniophotometer-with-rotating-mirror\/","title":{"rendered":"Goniophotometer with Rotating Mirror"},"content":{"rendered":"<p>LSG-2000 <a href=\"https:\/\/www.lisungroup.com\/products\/goniophotometer\/\" target=\"_blank\" rel=\"noopener\">\u0645\u0642\u064a\u0627\u0633 \u0632\u0627\u0648\u064a\u0629 \u0627\u0644\u0636\u0648\u0621<\/a> with Rotating Mirror is also called the Moving Mirror Goniophotometer. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The darkroom can be designed according to the customer\u2019s existing room size. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.<\/p>\n<div id=\"attachment_3595\" class=\"wp-caption aligncenter\" style=\"width: 2011px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-3595 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle.jpg\" sizes=\"(max-width: 2001px) 100vw, 2001px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle.jpg 2001w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle-400x117.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle-768x225.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle-1920x562.jpg 1920w\" alt=\"\" width=\"2001\" height=\"586\" aria-describedby=\"caption-attachment-3595\" title=\"\"><\/p>\n<p id=\"caption-attachment-3595\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">LSG-2000 Moving Mirror Goniophotometer Principle<\/span><\/p>\n<\/div>\n<div id=\"product-tab\" class=\"woocommerce-tabs woocommerce-tabs-mnuoobsanjog9tqcdrnax9f3ei9bm4g\">\n<div class=\"resp-tabs-container\">\n<div id=\"tab-description\" class=\"tab-content resp-tab-content resp-tab-content-active\" aria-labelledby=\"tab_item-0\">\n<div id=\"attachment_6328\" class=\"wp-caption aligncenter\" style=\"width: 2049px;\">\n<p><img decoding=\"async\" class=\"wp-image-6328 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1.jpg\" sizes=\"(max-width: 2039px) 100vw, 2039px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1.jpg 2039w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1-400x117.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1-768x224.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1-1920x561.jpg 1920w\" alt=\"LSG-2000 Moving Detector Goniophotometer Dark Room\" width=\"2039\" height=\"596\" aria-describedby=\"caption-attachment-6328\" title=\"\"><\/p>\n<p id=\"caption-attachment-6328\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">LSG-2000 Moving Detector Goniophotometer Dark Room<\/span><\/p>\n<\/div>\n<p><strong>\u0642\u064a\u0627\u0633:<br \/>\n<\/strong>Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution (Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc.<\/p>\n<p><strong>\u0642\u064a\u0627\u0633\u064a \uff1a \u0642\u064a\u0627\u0633\u064a<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> &quot;\u0627\u0644\u0642\u064a\u0627\u0633\u0627\u062a \u0627\u0644\u0628\u0635\u0631\u064a\u0629 \u0648\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0627\u0644\u0625\u0636\u0627\u0621\u0629 \u0630\u0627\u062a \u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u0635\u0644\u0628\u0629&quot;<br \/>\n<a href=\"https:\/\/www.lisungroup.cn\/wp-content\/uploads\/2019\/07\/EN13032-1-2004AC-2005.pdf\" target=\"_blank\" rel=\"noopener\">EN13032-1<\/a> \"\u0627\u0644\u0625\u0636\u0627\u0621\u0629 \u0648\u0627\u0644\u0625\u0636\u0627\u0621\u0629 - \u0642\u064a\u0627\u0633 \u0648\u0639\u0631\u0636 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0636\u0648\u0626\u064a\u0629 \u0644\u0644\u0645\u0635\u0627\u0628\u064a\u062d \u0648\u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0625\u0646\u0627\u0631\u0629 - \u0627\u0644\u062c\u0632\u0621 1: \u0627\u0644\u0642\u064a\u0627\u0633 \u0648\u0635\u064a\u063a\u0629 \u0627\u0644\u0645\u0644\u0641\u061b \u0627\u0644\u0646\u0633\u062e\u0629 \u0627\u0644\u0623\u0644\u0645\u0627\u0646\u064a\u0629 EN 13032-1:2004+A1:2012\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> &quot;\u0642\u064a\u0627\u0633 \u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0644\u0648\u0645\u0646 \u0644\u0645\u0635\u0627\u062f\u0631 \u0636\u0648\u0621 LED&quot;<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CIE-121-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-121<\/a> \"\u0627\u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0636\u0648\u0626\u064a \u0648\u0627\u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0636\u0648\u0626\u064a \u0644\u0644\u0625\u0646\u0627\u0631\u0629\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-70-1987-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-70 <\/a>\u00a0\u201cThe Measurement of Absolute Luminous Intensity Distribution\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESNA_LM-75-2001-Goniophotometer-Types-and-Photometric-Coordinates.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-75<\/a>\u00a0 \u201cGoniophotometerTypes and Photometric Coordinates\u201d<\/p>\n<p><strong>Features:<\/strong><br \/>\n- \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u062f\u0648\u0651\u0627\u0631 \u0645\u0646 \u0634\u0631\u0643\u0629 \u0645\u064a\u062a\u0633\u0648\u0628\u064a\u0634\u064a \u0627\u0644\u064a\u0627\u0628\u0627\u0646\u064a\u0629 MITSUBISHI MOTORS \u0648\u0646\u0638\u0627\u0645 \u0641\u0643 \u062a\u0634\u0641\u064a\u0631 \u0627\u0644\u0632\u0627\u0648\u064a\u0629 \u0645\u0646 \u0623\u0644\u0645\u0627\u0646\u064a\u0627. \u0648\u0647\u064a \u062a\u0633\u0627\u0639\u062f \u0639\u0644\u0649 \u062f\u0648\u0631\u0627\u0646 \u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0632\u0648\u0627\u064a\u0627 \u0628\u0633\u0644\u0627\u0633\u0629 \u0648\u0628\u062f\u0642\u0629 \u0639\u0627\u0644\u064a\u0629. \u0625\u0646\u0647 \u0645\u0633\u062a\u0642\u0631 \u0644\u0644\u063a\u0627\u064a\u0629 \u0639\u0646\u062f \u0627\u0644\u0628\u062f\u0621 \u0648\u0627\u0644\u062a\u0648\u0642\u0641.<br \/>\n\u2022 The working principles are according to IESNA and CIE. The LSG-2000 completely meets the <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESLM-79-LM-80-Chinese-Version-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">LM-80<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESNA_LM-75-2001-Goniophotometer-Types-and-Photometric-Coordinates.pdf\" target=\"_blank\" rel=\"noopener\">LM-75<\/a>, GB, EN13032-1 and <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CIE-121-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE121-1996<\/a> standards.<br \/>\n\u2022 Special collimation device with laser cross line help you installaing the position of luminaires undertest conveniently and accurately.<\/p>\n<p><strong>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a:<\/strong><br \/>\n\u2022 The mirror rotates around the luminaire under test with an angle of (\u03b3) \u00b1180\u00b0 (or 0-360\u00b0) and the luminaire rotates around itself with an angle of (C) \u00b1180\u00b0 (or 0-360\u00b0).<br \/>\n- \u062f\u0642\u0629 \u0627\u0644\u0632\u0627\u0648\u064a\u0629: 0.05 \u062f\u0631\u062c\u0629\u060c \u062f\u0642\u0629 \u0627\u0644\u0632\u0627\u0648\u064a\u0629: 0.001 \u062f\u0631\u062c\u0629<br \/>\n\u2022 Accuracy of\u00a0<a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/photo-detector.html\" target=\"_blank\" rel=\"noopener\">\u0643\u0627\u0634\u0641 \u0627\u0644\u0635\u0648\u0631<\/a>: Constant temperature\u00a0<a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/photo-detector.html\" target=\"_blank\" rel=\"noopener\">\u0643\u0627\u0634\u0641 \u0627\u0644\u0635\u0648\u0631<\/a>\u00a0DIN5032-6\/CIE pub1. \u0631\u0642\u0645 69 \u0627\u0644\u0641\u0626\u0629 L<br \/>\n- \u064a\u0645\u0643\u0646 \u0644\u0628\u0631\u0646\u0627\u0645\u062c LISUN goniophotometer \u062a\u0635\u062f\u064a\u0631 \u0645\u0644\u0641\u0627\u062a \u0628\u062a\u0646\u0633\u064a\u0642\u0627\u062a CIE \u0648IES \u0648LDT \u0648\u063a\u064a\u0631\u0647\u0627 \u0645\u0646 \u0627\u0644\u0645\u0644\u0641\u0627\u062a \u0628\u062a\u0646\u0633\u064a\u0642 CIE. \u064a\u0645\u0643\u0646 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0647\u0630\u0647 \u0627\u0644\u0623\u0646\u0648\u0627\u0639 \u0645\u0646 \u0645\u0644\u0641\u0627\u062a \u0627\u0644\u062a\u0646\u0633\u064a\u0642\u0627\u062a \u0639\u0628\u0631 \u0628\u0631\u0627\u0645\u062c \u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0625\u0636\u0627\u0621\u0629 \u0648\u0627\u0644\u0625\u0646\u0627\u0631\u0629 \u0627\u0644\u0623\u062e\u0631\u0649 \u0645\u062b\u0644 DiaLux.<br \/>\n\u2022 Connect goniophotometer to PC via USB cable. English version software can run on Win7, Win8, Win10 Win11.<br \/>\n\u2022 LSG-2000 can be used together with a USB CCD Spectrometer to test spatial CCT Distribution and other Spectral color parameters. We call this system \u201cGoniospectroradiometer (LSG-2000CCD)\u201d. Please download the brochure for LSG-2000CCD.<\/p>\n<table style=\"width: 94.1357%;\" border=\"1\" width=\"1144\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td style=\"width: 19.2476%;\">\u0646\u0645\u0648\u0630\u062c LISUN<\/td>\n<td style=\"width: 17.3997%;\">LSG-2000B (Big Size)<\/td>\n<td style=\"width: 18.5855%;\">LSG-2000 (Standard Size)<\/td>\n<td style=\"width: 18.6096%;\">LSG-2000S (Small Size)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19.2476%;\">Measure Non-Flood Lamp<\/td>\n<td style=\"width: 17.3997%;\">\u03a6 1600*800mm, 50kg<\/td>\n<td style=\"width: 18.5855%;\">\u03a6 1400*500mm, 40kg<\/td>\n<td style=\"width: 18.6096%;\">\u03a6 1000*460mm, 30kg<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19.2476%;\">Measure Flood Lamp<\/td>\n<td style=\"width: 17.3997%;\">600*600mm, 50kg<\/td>\n<td style=\"width: 18.5855%;\">600*600mm, 40kg<\/td>\n<td style=\"width: 18.6096%;\">400*400mm, 30kg<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19.2476%;\">\u0642\u064a\u0627\u0633 \u0627\u0644\u0637\u0627\u0642\u0629 (W)<\/td>\n<td style=\"width: 17.3997%;\">600V\/10A, AC\/DC<\/td>\n<td style=\"width: 18.5855%;\">600V\/10A, AC\/DC<\/td>\n<td style=\"width: 18.6096%;\">600V\/10A, AC\/DC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>LSG-2000 Goniophotometer with Rotating Mirror is also called the Moving Mirror Goniophotometer. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The darkroom can be designed according to the customer\u2019s existing room size. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":410,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[91],"class_list":["post-2333","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lsg-2000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts\/2333","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/comments?post=2333"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts\/2333\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/media\/410"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/media?parent=2333"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/categories?post=2333"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/tags?post=2333"}],"curies":[{"name":"\u0648\u0648\u0631\u062f\u0628\u0631\u064a\u0633","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}