{"id":2406,"date":"2025-06-19T19:35:35","date_gmt":"2025-06-19T11:35:35","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/ccd-spectroradiometer\/"},"modified":"2025-06-27T14:48:26","modified_gmt":"2025-06-27T06:48:26","slug":"ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ar\/%d9%85%d9%86%d8%aa%d8%ac%d8%a7%d8%aa\/ccd-spectroradiometer\/","title":{"rendered":"\u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0637\u064a\u0641 CCD"},"content":{"rendered":"<p>LMS-7000 spectroradiometer applied with Japanese high-precision CCD detector, which has excellent speed, high stability and high accuracy.<br \/>\n\u2022\u00a0The following wavelength range is with 0.8nm FWHM:<\/p>\n<table border=\"1\" width=\"921\" cellspacing=\"1\" cellpadding=\"1\" align=\"center\">\n<tbody>\n<tr>\n<td>LMS-7000UV<\/td>\n<td>LMS-7000UV-VIS<\/td>\n<td>LMS-7000VIS<\/td>\n<td>LMS-7000VIS-NIR<\/td>\n<td>LMS-7000UV-VIS-NIR<\/td>\n<\/tr>\n<tr>\n<td>200~400nm<\/td>\n<td>200~800nm<\/td>\n<td>350~950nm<\/td>\n<td>350~1050nm<\/td>\n<td>200~1050nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u2022 Integration time: 0.5ms to 1,0000ms<br \/>\n\u2022 CCD detector is 3648pix which size is 8\u03bcm\u00d7200m\u03bcm<br \/>\n\u2022\u00a0SNR (Signal to Noise Ratio) is 1000: 1 (Full range). A\/D is 16bit<br \/>\n\u2022 Communicate with PC by USB2.0. The software has a rich re-develop platform which can run on Win7, Win8, Win10, Win11<br \/>\n\u2022 Optical fiber port is SMA905<\/p>\n<p><strong>\u0642\u064a\u0627\u0633\u064a<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> &quot;\u0627\u0644\u0642\u064a\u0627\u0633\u0627\u062a \u0627\u0644\u0628\u0635\u0631\u064a\u0629 \u0648\u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0627\u0644\u0625\u0636\u0627\u0621\u0629 \u0630\u0627\u062a \u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u0635\u0644\u0628\u0629&quot;<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> &quot;\u062a\u0646\u0633\u064a\u0642 \u0627\u0644\u0645\u0644\u0641 \u0627\u0644\u0642\u064a\u0627\u0633\u064a \u0644\u0640 IESNA \u0644\u0644\u0646\u0642\u0644 \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a \u0644\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0636\u0648\u0626\u064a\u0629 \u0648\u0627\u0644\u0645\u0639\u0644\u0648\u0645\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0635\u0644\u0629&quot;<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\u0633\u064a \u0622\u064a \u0625\u064a 177<\/a> &quot;\u062a\u0642\u062f\u064a\u0645 \u0627\u0644\u0623\u0644\u0648\u0627\u0646 \u0644\u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u0636\u0648\u0621 LED \u0627\u0644\u0623\u0628\u064a\u0636&quot;<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\u0633\u064a \u0627\u064a \u0627\u064a 84<\/a> &quot;\u0642\u064a\u0627\u0633 \u0627\u0644\u062a\u062f\u0641\u0642 \u0627\u0644\u0636\u0648\u0626\u064a&quot;<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">\u0633\u064a \u0622\u064a \u0625\u064a-13.3<\/a> &quot;\u0637\u0631\u064a\u0642\u0629 \u0642\u064a\u0627\u0633 \u0648\u062a\u062d\u062f\u064a\u062f \u062e\u0635\u0627\u0626\u0635 \u062a\u062c\u0633\u064a\u062f \u0627\u0644\u0644\u0648\u0646 \u0644\u0645\u0635\u0627\u062f\u0631 \u0627\u0644\u0636\u0648\u0621&quot;<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> &quot;\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0644\u0648\u0646\u064a\u0629 \u0645\u0646\u062a\u062c\u0627\u062a \u0627\u0644\u0625\u0636\u0627\u0621\u0629 \u0630\u0627\u062a \u0627\u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u0635\u0644\u0628\u0629 \u0644\u0644\u0645\u0635\u0627\u0628\u064a\u062d \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629&quot;<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(\u0627\u0644\u0627\u062a\u062d\u0627\u062f \u0627\u0644\u0623\u0648\u0631\u0648\u0628\u064a) 2019\/2015<\/a> &quot;\u0627\u0644\u0644\u0627\u0626\u062d\u0629 \u0627\u0644\u0645\u0641\u0648\u0636\u0629 \u0645\u0646 \u0627\u0644\u0645\u0641\u0648\u0636\u064a\u0629&quot;<\/p>\n<p><strong>Typical Application:<br \/>\n<\/strong>The LMS-7000 is for LED color &amp; lumen test. It works with <a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_blank\" rel=\"noopener noreferrer\">\u062f\u0645\u062c \u0627\u0644\u0645\u062c\u0627\u0644<\/a> and standard lamp as a system: <a href=\"https:\/\/www.lisungroup.com\/products\/led-test-instruments\/ccd-spectroradiometer-integrating-sphere-compact-system.html\" target=\"_blank\" rel=\"noopener\">LPCE-3 CCD Spectroradiometer Integrating Sphere Compact System<\/a>. This system can do the following test.<\/p>\n<p><strong>\u0642\u064a\u0627\u0633:<br \/>\n<\/strong>Colorimetric: Chromaticity Coordinate (x, y) and (u, v), Relative Spectral Power Distribution P(\u03bb), Correlated Color Temperature (Tc), Color Rendering Index (Ra, R1 to R15), Color Difference, Dominant Wavelength, Peak Wavelength, Half-bandwidth, Spectral Purity, TM30 (Rf, Rg), CQS<br \/>\nPhotometric: Luminous Flux (Lumen), Luminous Efficiency, Radiant Power, EEI, PAR, PPF<br \/>\nElectrical: Voltage, Current, Power, Power Factor, Harmonic (Optional)<\/p>\n<p><strong>\u0645\u0648\u0627\u0635\u0641\u0629:<br \/>\n<\/strong>\u2022\u00a0Spectral Resolution: \u00b10.2nm<br \/>\n\u2022\u00a0Reproducibility: \u00b10.5nm<br \/>\n\u2022\u00a0Accuracy of Chromaticity Coordinate (\u0394x, \u0394y): \u00b10.003<br \/>\n\u2022 Correlated Color Temperature CCT: 1, 500K ~ 25, 000K, CCT Accuracy:\u00b10.5%<br \/>\n\u2022 High spectral resolution, high sensitivity and excellent reliability<\/p>\n<p><strong>Other Applications:<br \/>\n<\/strong>The LMS-7000 can also work with other accessories. It can be used in the following field and area. Please contact LISUN sales dept for the detail solution and spectroradiometer price.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-1990 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer.jpg\" sizes=\"(max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer.jpg 700w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer-400x180.jpg 400w\" alt=\"LMS-7000 CCD Spectroradiometer\" width=\"700\" height=\"315\" title=\"\"><\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-3-ccd-spectroradiometer-integrating-sphere-compact-system-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-3 (LMS-7000) LISUN LPCE-3 (LMS-7000) \u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0637\u064a\u0641 \u0627\u0644\u0636\u0648\u0626\u064a CCD \u0627\u0644\u0645\u062f\u0645\u062c \u0628\u0646\u0638\u0627\u0645 \u0627\u0644\u0645\u062c\u0627\u0644 \u0627\u0644\u0645\u062f\u0645\u062c \u0627\u0644\u0645\u062f\u0645\u062c - \u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0645\u062a\u062f\u0627\u0648\u0644\u0629 \u0644\u0645\u0627 \u0628\u0639\u062f \u0627\u0644\u0628\u064a\u0639\u00a0<\/span><\/a><br \/>\n<\/strong>\u064a\u0648\u062c\u062f \u0646\u0638\u0627\u0645 LISUN LPCE-3 \u0641\u064a \u0627\u0644\u0633\u0648\u0642 \u0645\u0646\u0630 \u0623\u0643\u062b\u0631 \u0645\u0646 10 \u0633\u0646\u0648\u0627\u062a\u060c \u0648\u0642\u062f \u0642\u0627\u0645 \u0641\u0631\u064a\u0642 \u062e\u062f\u0645\u0629 \u0645\u0647\u0646\u062f\u0633\u064a LISUN \u0628\u0627\u0644\u0641\u0639\u0644 \u0628\u062a\u0644\u062e\u064a\u0635 \u0645\u0639\u0638\u0645 \u0623\u0633\u0626\u0644\u0629 \u0648\u0623\u062c\u0648\u0628\u0629 \u0645\u0627 \u0628\u0639\u062f \u0627\u0644\u0628\u064a\u0639 \u0641\u064a \u0627\u0644\u0631\u0627\u0628\u0637 \u0623\u0639\u0644\u0627\u0647. \u064a\u064f\u0631\u062c\u0649 \u0642\u0631\u0627\u0621\u062a\u0647\u0627 \u0628\u0639\u0646\u0627\u064a\u0629\u060c \u064a\u0645\u0643\u0646\u0643 \u062d\u0644 \u0645\u0639\u0638\u0645 \u0627\u0644\u0645\u0634\u0627\u0643\u0644 \u0628\u0646\u0641\u0633\u0643 \u0625\u0630\u0627 \u0643\u0627\u0646\u062a \u0644\u062f\u064a\u0643 \u0628\u0639\u0636 \u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0623\u062f\u0648\u0627\u062a. \u0633\u062a\u0633\u062a\u0645\u0631 LISUN \u0641\u064a \u062a\u062d\u062f\u064a\u062b \u0647\u0630\u0647 \u0627\u0644\u0635\u0641\u062d\u0627\u062a \u0648\u064a\u0645\u0643\u0646 \u0627\u0644\u0639\u062b\u0648\u0631 \u0639\u0644\u0649 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629 \u0641\u064a \u0631\u0627\u0628\u0637 \u0627\u0644\u0645\u0648\u0636\u0648\u0639 \u0647\u0630\u0627.<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-7000 spectroradiometer applied with Japanese high-precision CCD detector, which has excellent speed, high stability and high accuracy. \u2022\u00a0The following wavelength range is with 0.8nm FWHM: LMS-7000UV LMS-7000UV-VIS LMS-7000VIS LMS-7000VIS-NIR LMS-7000UV-VIS-NIR 200~400nm 200~800nm 350~950nm 350~1050nm 200~1050nm \u2022 Integration time: 0.5ms to 1,0000ms \u2022 CCD detector is 3648pix which size is 8\u03bcm\u00d7200m\u03bcm \u2022\u00a0SNR (Signal to Noise Ratio) [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3423,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[163],"class_list":["post-2406","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-7000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts\/2406","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/comments?post=2406"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts\/2406\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/media\/3423"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/media?parent=2406"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/categories?post=2406"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/tags?post=2406"}],"curies":[{"name":"\u0648\u0648\u0631\u062f\u0628\u0631\u064a\u0633","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}