{"id":2629,"date":"2025-06-19T19:37:52","date_gmt":"2025-06-19T11:37:52","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-62368-diameter-1-mm-length-20-mm-terminal-probe\/"},"modified":"2025-06-25T17:04:46","modified_gmt":"2025-06-25T09:04:46","slug":"%d9%85%d8%b3%d8%a8%d8%a7%d8%b1-%d8%b7%d8%b1%d9%81%d9%8a-%d8%a8%d9%82%d8%b7%d8%b1-1-%d9%85%d9%85-%d9%88%d8%b7%d9%88%d9%84-20-%d9%85%d9%85-%d9%88%d9%81%d9%82%d9%8b%d8%a7-%d9%84%d9%85%d8%b9%d9%8a%d8%a7","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ar\/%d9%85%d9%86%d8%aa%d8%ac%d8%a7%d8%aa\/%d9%85%d8%b3%d8%a8%d8%a7%d8%b1-%d8%b7%d8%b1%d9%81%d9%8a-%d8%a8%d9%82%d8%b7%d8%b1-1-%d9%85%d9%85-%d9%88%d8%b7%d9%88%d9%84-20-%d9%85%d9%85-%d9%88%d9%81%d9%82%d9%8b%d8%a7-%d9%84%d9%85%d8%b9%d9%8a%d8%a7\/","title":{"rendered":"\u0645\u0633\u0628\u0627\u0631 \u0637\u0631\u0641\u064a IEC 62368\u060c \u0642\u0637\u0631\u0647 1 \u0645\u0645\u060c \u0648\u0637\u0648\u0644\u0647 20 \u0645\u0645"},"content":{"rendered":"<p><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642:<\/strong><br \/>\nAccording to: IEC62368-1 Figure V.5 (V.1.6) IEC60065:2005 9.1.4.<\/p>\n<p><strong>\u0627\u0650\u0635\u0637\u0650\u0644\u0627\u062d\u0650\u064a\u0651:<\/strong><br \/>\nTest probe diameter: 1,0 mm<br \/>\nTest probe length: 20 mm<br \/>\nForce: 1 Newton<br \/>\n\u0627\u0644\u0645\u0627\u062f\u0629: \u0627\u0644\u0641\u0648\u0644\u0627\u0630 \u0627\u0644\u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0635\u062f\u0623\u060c \u0627\u0644\u0646\u0627\u064a\u0644\u0648\u0646.<\/p>\n<p><strong>\u0645\u0639\u064a\u0627\u0631:<\/strong><br \/>\nIEC 62368-1 \u201cAudio\/video, information and communication technology equipment \u2013 Part 1: Safety requirements\u201d<br \/>\nIEC 60065 &quot;\u0627\u0644\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\u0629 \u0627\u0644\u0635\u0648\u062a\u064a\u0629 \u0648\u0627\u0644\u0645\u0631\u0626\u064a\u0629 \u0648\u0645\u0627 \u0634\u0627\u0628\u0647\u0647\u0627 - \u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0633\u0644\u0627\u0645\u0629&quot;\u201c<\/p>\n<div id=\"attachment_13249\" class=\"wp-caption aligncenter\" style=\"width: 768px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-13249 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/09\/v5.png\" sizes=\"(max-width: 758px) 100vw, 758px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/09\/v5.png 758w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/09\/v5-400x166.png 400w\" alt=\"\" width=\"758\" height=\"315\" aria-describedby=\"caption-attachment-13249\" title=\"\"><\/p>\n<p id=\"caption-attachment-13249\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">\u0645\u0633\u0628\u0627\u0631 \u0637\u0631\u0641\u064a IEC 62368\u060c \u0642\u0637\u0631\u0647 1 \u0645\u0645\u060c \u0648\u0637\u0648\u0644\u0647 20 \u0645\u0645<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Application: According to: IEC62368-1 Figure V.5 (V.1.6) IEC60065:2005 9.1.4. Technical: Test probe diameter: 1,0 mm Test probe length: 20 mm Force: 1 Newton Material: Stainless steel, nylon. Standard: IEC 62368-1 \u201cAudio\/video, information and communication technology equipment \u2013 Part 1: Safety requirements\u201d IEC 60065 \u201cAudio, video and similar electronic apparatus \u2013 Safety requirements\u201d IEC 62368 Diameter [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3594,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[371],"class_list":["post-2629","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-smt-106t"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts\/2629","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/comments?post=2629"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts\/2629\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/media\/3594"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/media?parent=2629"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/categories?post=2629"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/tags?post=2629"}],"curies":[{"name":"\u0648\u0648\u0631\u062f\u0628\u0631\u064a\u0633","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}