{"id":2852,"date":"2025-06-19T19:41:24","date_gmt":"2025-06-19T11:41:24","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60669-1-clause-18-3-tungsten-halogen-lamp-load-cabinet\/"},"modified":"2025-06-25T13:15:41","modified_gmt":"2025-06-25T05:15:41","slug":"iec-60669-1-clause-18-3-tungsten-halogen-lamp-load-cabinet","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ar\/%d9%85%d9%86%d8%aa%d8%ac%d8%a7%d8%aa\/iec-60669-1-clause-18-3-tungsten-halogen-lamp-load-cabinet\/","title":{"rendered":"IEC 60669-1 Clause 18.3 Tungsten\/Halogen Lamp Load Cabinet"},"content":{"rendered":"<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The Tungsten\/Halogen Lamp Load Cabinet is designed and manufactured according to the general technical requirements of IEC 60669-1:2017 Clause 18.3 (GB 16915.1-2024 Clause 18.3), IEC 60884-1:2022 (GB\/T 2099.1-2021), IEC 62368-1:2023 (GB\/T 4943.1-2022), IEC 60598-1:2024 (GB\/T 7000.1-2023) and other relevant standards. It is a special equipment for testing the switching capacity and normal operating life of switches for household and similar fixed electrical installations.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The rated voltage of the tested accessories such as switches is not more than 250V, and the rated current is not more than 16A.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The purpose is to assess whether accessories such as switches can withstand current surge impacts and electrical fatigue damage in normal use, whether there is contact adhesion or long-term disconnection, and whether there is excessive wear and other harmful consequences.<\/span><\/span> <\/span><\/p>\n<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The Tungsten\/Halogen Lamp Load Cabinet\u00a0has a control power switch, product power-on current, voltage and power, frequency display instrument, load power output switch, status and lamp group number indicator, current output and stop button, current (power) quantity selection switch, alarm, etc., and the voltage output adjustment knob is at the bottom of the front.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">There are tungsten lamp load combinations, AC contactors, relays, etc. inside, and the heat is cooled by strong wind diversion.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">There is a terminal block at the bottom, which is connected to the product in the test machine through wires and outputs current during the detection process.<\/span><\/span><\/span><\/p>\n<p><strong>\u0645\u0639\u064a\u0627\u0631:<\/strong><br \/>\nIEC 60669-1 (GB 16915.1) \u201cSwitches for household and similar fixed-electrical installations \u2013 Part 1: General requirements\u201d Clause 18.3<br \/>\nIEC 60884-1 (GB\/T 2099.1) \u201cPlugs and socket-outlets for household and similar purposes \u2013 Part 1: General requirements\u201d<br \/>\nIEC 62368-1 (GB\/T 4943.1) \u201cAudio\/video, information and communication technology equipment \u2013 Part 1: Safety requirements\u201d<br \/>\nIEC 60598-1 (GB\/T 7000.1) \u201cLuminaires \u2013 Part 1: General requirements and tests\u201d<\/p>\n<p><strong>\u0645\u0648\u0627\u0635\u0641\u0629:<\/strong><br \/>\n\u2022 Power Supply: Single-phase three-wire AC220 \u00b1 10%\/50Hz<br \/>\n\u2022 Digital voltage meter: voltage range 0-300V, accuracy \u00b1 0.5%\u00b1 2D<br \/>\n\u2022 Digital current meter: 0~40A, accuracy \u00b1 0.5%\u00b1 2D.<br \/>\n\u2022 Digital power meter: 0~9kW, accuracy \u00b1 0.5%\u00b1 2D.<br \/>\n\u2022 Loading method: Built -in 3 sets of 200W tungsten filament light\/halogen light combination, circulating and power on.<br \/>\n\u2022 Number of output channel: 1.<br \/>\n\u2022 Load power supply capacity: 7.5KVA<br \/>\n\u2022 The maximum output current is 20A, and the load is automatically cut off when it exceeds 22A.<br \/>\n\u2022 The maximum output voltage is 300V, and the load is automatically cut off when it exceeds 305V.<br \/>\n\u2022 Selection of tungsten filament\/halogen lights: each lamp is 200W power, divided into 1\/2\/3\/4\/10\/10 pieces combination.<br \/>\n\u2022 Digger: 0~999999 times can be set.<br \/>\n\u2022 With long sticky protection function: The long-stick limit time range is 0-99s and can be set.<\/p>\n<p><strong>Notes: DFX-WD20A Tungsten\/Halogen Lamp Load Cabinet usually should work together with LISUN <a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/6-position-plug-socket-switch-life-tester.html\" target=\"_blank\" rel=\"noopener\">CZKS-6 6 Position Plug Socket Switch Life Tester.<\/a><\/strong><\/p>\n<div id=\"attachment_14359\" class=\"wp-caption aligncenter\" style=\"width: 626px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14359 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/04\/K1JHA4P1GJ_P0I0AC0.jpg\" sizes=\"(max-width: 616px) 100vw, 616px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/04\/K1JHA4P1GJ_P0I0AC0.jpg 616w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/04\/K1JHA4P1GJ_P0I0AC0-361x400.jpg 361w\" alt=\"\" width=\"616\" height=\"682\" aria-describedby=\"caption-attachment-14359\" title=\"\"><\/p>\n<p id=\"caption-attachment-14359\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60669-1 Clause 18.3 Tungsten\/Halogen Lamp Load test<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The Tungsten\/Halogen Lamp Load Cabinet is designed and manufactured according to the general technical requirements of IEC 60669-1:2017 Clause 18.3 (GB 16915.1-2024 Clause 18.3), IEC 60884-1:2022 (GB\/T 2099.1-2021), IEC 62368-1:2023 (GB\/T 4943.1-2022), IEC 60598-1:2024 (GB\/T 7000.1-2023) and other relevant standards. It is a special equipment for testing the switching capacity and normal operating life of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3192,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[546],"class_list":["post-2852","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-dfx-wd20a"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts\/2852","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/comments?post=2852"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts\/2852\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/media\/3192"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/media?parent=2852"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/categories?post=2852"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/tags?post=2852"}],"curies":[{"name":"\u0648\u0648\u0631\u062f\u0628\u0631\u064a\u0633","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}