{"id":2879,"date":"2025-06-19T19:41:45","date_gmt":"2025-06-19T11:41:45","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/ul-1598-figures-19-17-1-and-19-17-2-water-spray-test-device\/"},"modified":"2025-06-19T19:41:45","modified_gmt":"2025-06-19T11:41:45","slug":"ul-1598-figures-19-17-1-and-19-17-2-water-spray-test-device","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ar\/%d9%85%d9%86%d8%aa%d8%ac%d8%a7%d8%aa\/ul-1598-figures-19-17-1-and-19-17-2-water-spray-test-device\/","title":{"rendered":"UL 1598 Figures 19.17.1 and 19.17.2 Water Spray Test Device"},"content":{"rendered":"<p>The UL Water Spray Test Device is fully meet UL 60507-ENGL 1999 of Figures 38.1 and 38.2 , ANSI Z21.58 Clause 5.23.1 Figures 12 and 13 , and the CSA 4.3-2004 standard. It complies with\u00a0 UL 1598 standard of Clause 19.17 Figures 19.17.1 and 19.17.2 , as well as the UL 153, UL 154B, UL 1703, UL 8750, UL 1741, UL 514B, UL 1278, and UL 1571 standards.<\/p>\n<p>The equipment program includes standard test options, allowing users to select the required standard test items and conduct tests without additional setup. Additionally, it features custom test options, enabling users to set test parameters independently to accommodate the testing of different samples.<\/p>\n<p><strong>Structure:<\/strong><br \/>\n\u2022 This system consists of a water supply control box (with a water tank) and six UL spray devices, designed for a comprehensive waterproof testing chamber.<br \/>\n\u2022 The water supply control box and spray devices are placed separately. After positioning the sample, the operator can start the test from the control panel, ensuring they remain at a safe distance from the test apparatus to better guarantee personal safety.<br \/>\n\u2022 Water hoses distribute water from the supply system to each spray device, ensuring the setup is orderly and aesthetically pleasing.<\/p>\n<p><strong>\u0645\u0648\u0627\u0635\u0641\u0629:<\/strong><br \/>\n\u2022 Suitable for conducting UL rain and 45\u00b0 spray tests on products.<br \/>\n\u2022 Each unit consists of two parts: the UL rain test device (three UL nozzles on the top) and the spray test device (one UL nozzle on the bottom).<br \/>\n\u2022 The nozzle frame is made of molded aluminum material, providing stable structure and easy cleaning.<br \/>\n\u2022 The nozzle frame is movable, with free vertical adjustment via a hand-cranked stainless steel wheel mechanism.<br \/>\n\u2022 The base of the frame is equipped with universal casters with brakes, facilitating easy movement and secure positioning.<br \/>\n\u2022 Number of frames: 6 sets.<br \/>\n\u2022 Adjustable nozzle height range: 1000~2000mm<br \/>\n\u2022 Nozzle height adjustment method: manual<br \/>\n\u2022 Number of nozzles: 4 per set, 6 sets total<br \/>\n\u2022 Environmental conditions: temperature 5\u2103 to 35\u2103, relative humidity \u226485%, power supply 380V, 5KVA<br \/>\n\u2022 Water spray convergence point height from ground: 0-1000mm<br \/>\n\u2022 Distribution of upper nozzles (strictly according to standard) as per Figures 19.17.1 and 19.17.2<br \/>\n\u2022 Lower nozzle spray angle: 45\u00b0 (horizontal direction)<br \/>\n\u2022 Pressure of each nozzle: 34.5 Kpa<br \/>\n\u2022 Number of pressure gauges: 4 per set, 6 sets total<br \/>\n\u2022 Pressure gauge brand: Hongqi<br \/>\n\u2022 Maximum allowable test sample size: 2435.3*1557.3*2008.8mm (W*D*H)<br \/>\n\u2022 Reference diagram for the distribution of the frames<\/p>\n<p><div id=\"attachment_14984\" style=\"width: 668px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-14984\" decoding=\"async\" class=\"wp-image-14984 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/57P@2H1MPT06HDSZ@92.png\" alt=\"\" width=\"658\" height=\"652\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/57P@2H1MPT06HDSZ@92.png 658w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/57P@2H1MPT06HDSZ@92-400x396.png 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/57P@2H1MPT06HDSZ@92-100x100.png 100w\" sizes=\"auto, (max-width: 658px) 100vw, 658px\" title=\"\"><\/p>\n<p id=\"caption-attachment-14984\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Figure 19.17.1<\/span><\/p>\n<\/div>\n<div id=\"attachment_14985\" style=\"width: 663px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-14985\" decoding=\"async\" class=\"wp-image-14985 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/K0T9A32CDO6XCWLJ4MO.png\" alt=\"\" width=\"653\" height=\"769\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/K0T9A32CDO6XCWLJ4MO.png 653w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/K0T9A32CDO6XCWLJ4MO-340x400.png 340w\" sizes=\"auto, (max-width: 653px) 100vw, 653px\" title=\"\"><\/p>\n<p id=\"caption-attachment-14985\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Figure 19.17.2<\/span><\/p>\n<\/div>\n<div id=\"attachment_14986\" style=\"width: 596px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-14986\" decoding=\"async\" class=\"wp-image-14986 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/Q7BCV29D5Z9VMFAEJL.png\" alt=\"\" width=\"586\" height=\"421\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/Q7BCV29D5Z9VMFAEJL.png 586w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/Q7BCV29D5Z9VMFAEJL-400x287.png 400w\" sizes=\"auto, (max-width: 586px) 100vw, 586px\" title=\"\"><\/p>\n<p id=\"caption-attachment-14986\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Diagram for the distribution of the frames<\/span><\/p>\n<\/div>\n<div id=\"attachment_14987\" style=\"width: 704px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-14987\" decoding=\"async\" class=\"wp-image-14987 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/W8KRQN8@LSCQP8M8.png\" alt=\"\" width=\"694\" height=\"556\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/W8KRQN8@LSCQP8M8.png 694w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/W8KRQN8@LSCQP8M8-400x320.png 400w\" sizes=\"auto, (max-width: 694px) 100vw, 694px\" title=\"\"><\/p>\n<p id=\"caption-attachment-14987\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Diagram of UL water spray test device<\/span><\/p>\n<\/div>\n<p><strong>Water Supply Control Chamber (with Water Tank):<\/strong><br \/>\n\u2022 Control functions: spray time control<br \/>\n\u2022 Control screen: MCGS 7-inch<br \/>\n\u2022 PLC controller: Panasonic(Japan)<br \/>\n\u2022 Electrical components: all imported brands including LS, Panasonic, Omron, and Anly<br \/>\n\u2022 Protection functions: leakage protection, overload protection, short circuit protection<br \/>\n\u2022 Water tank capacity: approximately 500L<br \/>\n\u2022 Water tank material: SUS304 stainless steel<br \/>\n\u2022 Water supply outlets: 12 channels (one for each frame, totaling 6 channels; one for each 45\u00b0 nozzle, totaling 6 channels)<br \/>\n\u2022 Water supply piping: high-quality hoses used for water supply are distributed to each device according to on-site layout, with each device controlled by a solenoid valve<br \/>\n\u2022 Internal piping material of the water supply machine: SUS304 stainless steel pipes<\/p>\n<div id=\"attachment_14988\" style=\"width: 386px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-14988\" decoding=\"async\" class=\"size-full wp-image-14988\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/07\/G@11RPG528DIASB1VP8GS.png\" alt=\"\" width=\"376\" height=\"357\" title=\"\"><\/p>\n<p id=\"caption-attachment-14988\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Water Supply Control Chamber<\/span><\/p>\n<\/div>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>The UL Water Spray Test Device is fully meet UL 60507-ENGL 1999 of Figures 38.1 and 38.2 , ANSI Z21.58 Clause 5.23.1 Figures 12 and 13 , and the CSA 4.3-2004 standard. It complies with\u00a0 UL 1598 standard of Clause 19.17 Figures 19.17.1 and 19.17.2 , as well as the UL 153, UL 154B, UL [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[573],"class_list":["post-2879","post","type-post","status-publish","format-standard","hentry","category-products","tag-ul-jlx1"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts\/2879","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/comments?post=2879"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/posts\/2879\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/media?parent=2879"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/categories?post=2879"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ar\/wp-json\/wp\/v2\/tags?post=2879"}],"curies":[{"name":"\u0648\u0648\u0631\u062f\u0628\u0631\u064a\u0633","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}