Online-Chat

+8615317905991

Notbeleuchtung Glühdrahttest

Inhaltsverzeichnis

Introduction to Glow-Wire Testing in Emergency Lighting Systems

Emergency lighting systems are critical for ensuring safety in low-visibility or hazardous conditions, particularly in commercial, industrial, and residential environments. Regulatory standards mandate rigorous flammability testing to assess material resistance to ignition and flame propagation. The glow-wire test, governed by IEC 60695-2-10 through IEC 60695-2-13, evaluates the fire hazard potential of insulating materials, enclosures, and components when exposed to high temperatures.

Der LISUN ZRS-3H Glühdrahtprüfgerät is a precision instrument designed to conduct these assessments with repeatability and compliance to international standards. This article examines the testing methodology, industry applications, and the technical superiority of the ZRS-3H in ensuring material safety across multiple sectors.

Technical Specifications of the LISUN ZRS-3H Glow-Wire Test Apparatus

The ZRS-3H is engineered for high-precision thermal testing, featuring:

  • Temperaturbereich: 300°C to 1000°C (±2°C accuracy)
  • Glow-Wire Dimensions: 4mm diameter nickel-chromium wire, compliant with IEC 60695-2-10
  • Test Force Adjustment: 1.0N ± 0.1N (adjustable via calibrated weights)
  • Probenhalter: Adjustable positioning for vertical or horizontal orientation
  • Timer Function: 0–999.9s (±0.1s resolution) for ignition duration measurement
  • Sicherheitsmerkmale: Overheat protection, automatic cut-off, and fume extraction compatibility

The apparatus supports testing under IEC, EN, UL, and GB standards, ensuring global applicability.

Testing Principle and Methodology

The glow-wire test simulates thermal stress caused by overheated components or electrical faults. A preheated wire is applied to the test specimen under controlled force and duration. Observations include:

  1. Ignition Time: Duration until sustained flaming occurs.
  2. Flame Persistence: Post-application burning duration.
  3. Material Behavior: Dripping, deformation, or carbonization.

Compliance thresholds vary by application:

  • Household Appliances (IEC 60335-1): ≤30s flame persistence at 750°C.
  • Automotive Electronics (ISO 20653): No ignition at 850°C.
  • Lighting Fixtures (IEC 60598-1): Non-propagation at 650°C.

Branchenspezifische Anwendungsfälle

1. Electrical and Electronic Equipment

Circuit boards, connectors, and insulating materials must resist thermal degradation. The ZRS-3H verifies flame-retardant properties in power supplies and control modules.

2. Household Appliances

Switches, thermostats, and motor housings undergo testing at 550°C–850°C to prevent fire risks in dishwashers, refrigerators, and HVAC systems.

3. Automotive Electronics

EV battery enclosures and infotainment systems are tested at elevated temperatures to meet ISO 20653 and LV 312 requirements.

4. Medizinische Geräte

Polymer casings for ventilators and imaging equipment must self-extinguish within 15s at 650°C per IEC 60601-1.

5. Aerospace and Aviation

Cabin lighting and wiring insulation are subjected to 960°C tests to comply with FAA flammability regulations.

Competitive Advantages of the ZRS-3H

  1. Calibration Stability: Proprietary PID temperature control minimizes drift.
  2. Modularer Aufbau: Interchangeable fixtures accommodate diverse specimen geometries.
  3. Datenaufzeichnung: Integrated software records temperature curves and ignition events for audit trails.
  4. Cross-Industry Compliance: Validates materials against IEC, UL, and GB/T 5169.10-2017.

Standards Referenced in Glow-Wire Testing

StandardApplication Scope
IEC 60695-2-10Basic glow-wire apparatus and test procedure
IEC 60695-2-11Entflammbarkeit der Endprodukte
UL 746APolymeric materials – flammability
GB/T 5169.10-2017Chinesische Entsprechung der IEC 60695-2-10

FAQ-Abschnitt

Q1: Was unterscheidet den ZRS-3H von herkömmlichen Glühdrahtprüfgeräten?
Der ZRS-3H bietet eine hervorragende Temperaturstabilität (±2 °C), eine automatische Kraftaufbringung und die Einhaltung zahlreicher internationaler Normen, wodurch reproduzierbare Ergebnisse gewährleistet werden.

F2: Wie oft sollte das Glühdrahtelement ausgetauscht werden?
Der Nickel-Chrom-Draht sollte vor jeder Testreihe überprüft und ersetzt werden, wenn die Oxidation oder Verformung mehr als 0,5 mm Abweichung beträgt.

F3: Kann der ZRS-3H vertikal orientierte Proben prüfen?
Ja, die verstellbare Halterung ermöglicht sowohl eine horizontale als auch eine vertikale Ausrichtung gemäß den Anforderungen der IEC 60695-2-12.

F4: Welche Sicherheitsvorkehrungen sind während der Prüfung erforderlich?
Die Bediener müssen eine Rauchabsaugung und hitzebeständige Handschuhe verwenden und die ASTM D3874 für Sicherheitsprotokolle im Labor einhalten.

F5: Ist das Gerät für die Prüfung von Großserien geeignet?
Mit schnellen Heizzyklen (≤3min bis 1000°C) und automatischer Protokollierung ist das ZRS-3H für QC-Labors und F&E-Einrichtungen optimiert.

Diese technische Analyse unterstreicht die Rolle des ZRS-3H bei der Eindämmung von Brandgefahren in allen Industriezweigen und stärkt seine Stellung als Maßstab für die Validierung der Materialsicherheit.

Eine Nachricht hinterlassen

=