{"id":2390,"date":"2025-06-19T19:35:24","date_gmt":"2025-06-19T11:35:24","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/digital-power-meter-high-accuracy-ac-dc-model\/"},"modified":"2025-07-03T14:56:52","modified_gmt":"2025-07-03T06:56:52","slug":"digital-power-meter-high-accuracy-ac-dc-model","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/de\/produkte\/digital-power-meter-high-accuracy-ac-dc-model\/","title":{"rendered":"High Accuracy Digital Power Meter"},"content":{"rendered":"<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">LS2050 High Accuracy AC and DC Power Meter measuring instrument is a new generation of intelligent product that uses digital sampling technology to analyze waveforms.<\/span><\/span><\/span><\/p>\n<p>- <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">LS2050C\/LS2050C-IEC fully complies with the relevant requirements of LM-79-19, and the frequency test range is: 0.5Hz-100kHz.\u00a0<\/span><\/span><\/span><br \/>\n- <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The instrument is equipped with software that can test the following parameters: U(AC&amp;DC), I(AC&amp;DC), P(AC&amp;DC), Power Factor PF(AC), Displacement Factor DF(AC) and 0-50 total harmonics tested using IEC\/CSA method. <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/ls2050-calibration-certificate.pdf\" target=\"_blank\" rel=\"noopener\">Please click here to view the LS2050B\/LS2050C\/LS2050C-IEC test report sample.\u00a0<\/a><\/span><\/span><\/span><br \/>\n- <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The LS2050C-IEC is equipped with additional software (Additional fee is required based on LS2050C) that fully complies with the relevant requirements of <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/07\/BSENIEC61000-3-2-2019.pdf\" target=\"_blank\" rel=\"noopener\">EN\/IEC61000-3-2:2019<\/a>. <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/07\/ls2050c-iec61000-3-2-test-report.pdf\" target=\"_blank\" rel=\"noopener\">Please click here to view the LS2050C-IEC software test report sample<\/a>.<br \/>\n\u2022 RS232\/RS485 communication port.<br \/>\n<\/span><\/span><\/span><\/p>\n<p><strong>Standard:<\/strong><br \/>\n- \u00a0<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/07\/BSENIEC61000-3-2-2019.pdf\" target=\"_blank\" rel=\"noopener\">EN\/IEC6100-3-2:2019<\/a> \u201cElectromagnetic compatibility (EMC) \u2013 Part 3-2: Limits \u2013 Limits for harmonic current emissions (equipment input current \u226416 A per phase) (Incorporates Amendment A1: 2021)\u201d<br \/>\n\u2022 \u00a0LM-79-19 Optical and Electrical Measurements of Solid State Lighting Products<\/p>\n<table style=\"width: 100.356%; height: 286px;\" width=\"710\">\n<tbody>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 26px;\" colspan=\"2\" width=\"274\"><strong>Spezifikation:<\/strong><\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">Voltage (v)<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">Current (A)<\/td>\n<\/tr>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 26px;\" colspan=\"2\" width=\"274\">Input circuit type<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">Floating replacement input<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">Floating replacement input<\/td>\n<\/tr>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 26px;\" colspan=\"2\" width=\"274\">Input resistance<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">&gt; 1M\u03a9<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">&lt; 0.01\u03a9<\/td>\n<\/tr>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 52px;\" colspan=\"2\" rowspan=\"2\" width=\"274\">Reichweite<\/td>\n<td style=\"vertical-align: middle; height: 52px;\" rowspan=\"2\" width=\"218\">AC\/DC: 600V\/300V\/150V\/75V Automatic<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">AC\/DC: 20A\/8A\/2A\/0.5A<\/td>\n<\/tr>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">Automatic<\/td>\n<\/tr>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 26px;\" colspan=\"2\" width=\"274\">IS instantaneous Max<\/td>\n<td style=\"vertical-align: middle; height: 52px;\" rowspan=\"2\" width=\"218\">1600V<\/td>\n<td style=\"vertical-align: middle; height: 52px;\" rowspan=\"2\" width=\"218\">50A<\/td>\n<\/tr>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 26px;\" colspan=\"2\" width=\"274\">Permissible input<\/td>\n<\/tr>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 26px;\" colspan=\"2\" width=\"274\">Continuous max permissible input<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">800V<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">24A<\/td>\n<\/tr>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 26px;\" colspan=\"2\" width=\"274\">Input terminal<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">Small terminals<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"218\">Big terminals<\/td>\n<\/tr>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 52px;\" rowspan=\"2\" width=\"153\"><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Automatic range switching<\/span><\/span><\/span><\/td>\n<td style=\"vertical-align: middle; height: 26px;\" width=\"121\">Increase range<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" colspan=\"2\" width=\"436\">Measured value over 110% rated range<\/td>\n<\/tr>\n<tr style=\"height: 26px;\">\n<td style=\"vertical-align: middle; height: 26px;\" width=\"121\">Decrease range<\/td>\n<td style=\"vertical-align: middle; height: 26px;\" colspan=\"2\" width=\"436\">Measured value lower than 80% rated range<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Die Genauigkeit:<\/strong><\/p>\n<table style=\"width: 100.483%; height: 148px;\" width=\"671\">\n<tbody>\n<tr>\n<td style=\"vertical-align: middle;\" width=\"109\">LISUN-Modell<\/td>\n<td style=\"vertical-align: middle;\" width=\"93\">Spannung<\/td>\n<td style=\"vertical-align: middle;\" width=\"93\">Aktuell<\/td>\n<td style=\"vertical-align: middle;\" width=\"91\">\u00a0Strom<\/td>\n<td style=\"vertical-align: middle;\" width=\"163\">PF\/DF<\/td>\n<td style=\"vertical-align: middle;\" width=\"122\">Frequenz<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle;\" width=\"109\">LS2050C<\/td>\n<td style=\"vertical-align: middle;\" colspan=\"3\" rowspan=\"2\" width=\"277\">\u00b1(0.1% read value +0.1%range +1 digit)<\/td>\n<td style=\"vertical-align: middle;\" rowspan=\"2\" width=\"163\">\u00b1(0.002+0.001%read value+1 digit)<\/td>\n<td style=\"vertical-align: middle;\" rowspan=\"2\" width=\"122\">\u00b1(0.1%read value+1 digit)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle;\" width=\"109\">LS2050C-IEC<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: middle;\" width=\"109\">LS2050B<\/td>\n<td style=\"vertical-align: middle;\" colspan=\"3\" width=\"277\">\u00b1(0.4% read value +0.1%range +1 digit)<\/td>\n<td style=\"vertical-align: middle;\" width=\"163\">\u00b1(0.004+0.001%read value+1 digit)<\/td>\n<td style=\"vertical-align: middle;\" width=\"122\">\u00b1(0.1%read value+1 digit)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"saswp-g-review-panel\">\n<div class=\"saswp-glg-review-body\">\n<div class=\"saswp-rv-img\"><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>LS2050 High Accuracy AC and DC Power Meter measuring instrument is a new generation of intelligent product that uses digital sampling technology to analyze waveforms. \u2022 LS2050C\/LS2050C-IEC fully complies with the relevant requirements of LM-79-19, and the frequency test range is: 0.5Hz-100kHz.\u00a0 \u2022 The instrument is equipped with software that can test the following parameters: [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3134,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[147],"class_list":["post-2390","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls2050"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2390","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/comments?post=2390"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2390\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media\/3134"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media?parent=2390"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/categories?post=2390"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/tags?post=2390"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}