{"id":2402,"date":"2025-06-19T19:35:24","date_gmt":"2025-06-19T11:35:24","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/high-precision-ccd-spectroradiometer\/"},"modified":"2025-07-03T15:09:12","modified_gmt":"2025-07-03T07:09:12","slug":"high-precision-ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/de\/produkte\/high-precision-ccd-spectroradiometer\/","title":{"rendered":"High-accuracy\u00a0 Spectroradiometer"},"content":{"rendered":"<p>LMS-9000C High Precision CCD Spectroradiometer is according to LM-79 clause 9.1. It is designed for any visible optical spectrum distribution analysis, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED optical spectrum analyzer is used as a transfer standard for photometric, colorimetric a<a id=\"mcegrid16\" class=\"mce-active\" href=\"https:\/\/www.lisungroup.com\/wp-admin\/post.php?post=1962&amp;action=edit#\" data-mce-x=\"6\" data-mce-y=\"1\" target=\"_blank\" rel=\"noopener\"><\/a>nd radiometric applications.<\/p>\n<p>LMS-9000C can do quick test with high accuracy. It used in scientific lab. It works with <a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_blank\" rel=\"noopener\">Integrationskugel<\/a> and standard lamp as a system: <a href=\"https:\/\/www.lisungroup.com\/products\/led-test-instruments\/high-precision-spectroradiometer-integrating-sphere-system.html\" target=\"_blank\" rel=\"noopener\">LPCE-2 High Precision Spectroradiometer Integrating Sphere System<\/a>.<\/p>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"Farbwiedergabe von wei\u00dfen LED-Lichtquellen\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"Die Messung des Lichtstroms\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"Verfahren zur Messung und Bestimmung der Farbwiedergabeeigenschaften von Lichtquellen\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Optische und elektrische Messungen von Festk\u00f6rperbeleuchtungsprodukten\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"IESNA Standard File Format for the Electronic Transfer of Photometric Data and Related information\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"Messung des Lumenerhalts von LED-Lichtquellen\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"Spezifikationen f\u00fcr den Farbort von Festk\u00f6rperleuchtmitteln f\u00fcr elektrische Lampen\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(EU) 2019\/2015<\/a> \"DELEGIERTE VERORDNUNG DER KOMMISSION\".<\/p>\n<p><strong>Messung:<br \/>\n<\/strong>- Farbmetrik: Chromatizit\u00e4tskoordinaten, CCT, Farbverh\u00e4ltnis, Spitzenwellenl\u00e4nge, halbe Bandbreite, dominante Wellenl\u00e4nge, Farbreinheit, CRI, CQS, TM-30 (Rf, Rg), Spektraltest<br \/>\n- Photometrisch: Lichtstrom, Lichtausbeute, Strahlungsleistung, WPE, EQE, EEI, Energieeffizienzklasse, Pupillenlichtstrom, Pupillenlichtstromeffizienz, Pupillenfaktor, kirtopischer Lichtstrom, PAR und PPF von Pflanzenwachstumslampen<br \/>\n\u2022 Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic<br \/>\n\u2022 LED optical maintenance test: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time<\/p>\n<p><strong>Spezifikation:<\/strong><br \/>\n- Spektrale Wellenl\u00e4ngengenauigkeit: \u00b10,3nm, Wellenl\u00e4ngenreproduzierbarkeit: \u00b10,1nm<br \/>\n- Probenabtastschritte: \u00b10,1nm<br \/>\n- Genauigkeit der Chromatizit\u00e4tskoordinaten (\u0394x, \u0394y): \u00b10,002 (unter Standard-A-Lampe)<br \/>\n- Korrelierte Farbtemperatur CCT: 1.500K~100.000K, CCT-Genauigkeit: \u00b10,3%<br \/>\n- Farbwiedergabe-Index-Bereich: 0~100.0, Genauigkeit: \u00b1(0.3%rd\u00b10.3)<br \/>\n- Lichtstrombereich: 0,01-200.000lm; Photometrische Lineargenauigkeit: \u00b10,5%<br \/>\n- Streulicht: &lt;0,015%(600nm) und &lt;0,03%(435nm)<br \/>\n- Integrationszeit: 0,1~10.000ms<br \/>\n- Es kann die Temperaturen innerhalb und au\u00dferhalb der Ulbricht-Kugel messen<br \/>\n\u2022 Total flux testing method: spectrum, photometric and spectrum with photometric revision<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 20%;\"><strong>LISUN-Modell<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000C<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000CUV-VIS<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000CVIS-NIR<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000CUV<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 20%;\"><strong>Wellenl\u00e4nge<\/strong><\/td>\n<td style=\"width: 20%;\">350-800nm<\/td>\n<td style=\"width: 20%;\">200-800nm<\/td>\n<td style=\"width: 20%;\">350-1050nm<\/td>\n<td style=\"width: 20%;\">200-400nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The LMS-9000C (which is updated on LMS-9000B) uses the band pass-filter wheel correcting technique, spectrometer &amp; broadband-radiometer &amp; photometer combined technique, and modified NIST stray light correction technology. The LMS-9000C spectroradiometer can realize ultra low stray light and super photometry linearity in overall dynamic range.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-3557 aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/High-Precision-CCD-Spectroradiometer.jpg\" sizes=\"(max-width: 600px) 100vw, 600px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/High-Precision-CCD-Spectroradiometer.jpg 600w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/High-Precision-CCD-Spectroradiometer-400x193.jpg 400w\" alt=\"Hochpr\u00e4zises CCD-Spektroradiometer\" width=\"600\" height=\"289\" title=\"\"><\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9000c-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-2(LMS-9000C) Hochpr\u00e4zisions-Spektralradiometer-Integrationskugelsystem - H\u00e4ufig gestellte Fragen nach dem Kauf (FAQ).<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-2 (LMS-9000C) Hochpr\u00e4zisions-Spektralradiometer Integrating Sphere System wurden auf dem Markt f\u00fcr mehr als 10 Jahren, LISUN Ingenieure Service-Team bereits die meisten der After Sales Fragen und Antworten in der obigen Link. Bitte lesen Sie es sorgf\u00e4ltig, Sie k\u00f6nnen die meisten Probleme selbst l\u00f6sen, wenn Sie einige Fragen bei der Verwendung der Instrumente haben. LISUN wird diese Seiten weiterhin aktualisieren und weitere FAQ finden Sie unter diesem Link.<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-9000C High Precision CCD Spectroradiometer is according to LM-79 clause 9.1. It is designed for any visible optical spectrum distribution analysis, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED optical spectrum analyzer is used as a transfer standard for photometric, colorimetric and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3427,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[159],"class_list":["post-2402","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-9000c"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2402","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/comments?post=2402"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2402\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media\/3427"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media?parent=2402"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/categories?post=2402"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/tags?post=2402"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}