{"id":2406,"date":"2025-06-19T19:35:35","date_gmt":"2025-06-19T11:35:35","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/ccd-spectroradiometer\/"},"modified":"2025-06-27T14:48:26","modified_gmt":"2025-06-27T06:48:26","slug":"ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/de\/produkte\/ccd-spectroradiometer\/","title":{"rendered":"CCD-Spektroradiometer"},"content":{"rendered":"<p>LMS-7000 spectroradiometer applied with Japanese high-precision CCD detector, which has excellent speed, high stability and high accuracy.<br \/>\n\u2022\u00a0The following wavelength range is with 0.8nm FWHM:<\/p>\n<table border=\"1\" width=\"921\" cellspacing=\"1\" cellpadding=\"1\" align=\"center\">\n<tbody>\n<tr>\n<td>LMS-7000UV<\/td>\n<td>LMS-7000UV-VIS<\/td>\n<td>LMS-7000VIS<\/td>\n<td>LMS-7000VIS-NIR<\/td>\n<td>LMS-7000UV-VIS-NIR<\/td>\n<\/tr>\n<tr>\n<td>200~400nm<\/td>\n<td>200~800nm<\/td>\n<td>350~950nm<\/td>\n<td>350~1050nm<\/td>\n<td>200~1050nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u2022 Integration time: 0.5ms to 1,0000ms<br \/>\n\u2022 CCD detector is 3648pix which size is 8\u03bcm\u00d7200m\u03bcm<br \/>\n\u2022\u00a0SNR (Signal to Noise Ratio) is 1000: 1 (Full range). A\/D is 16bit<br \/>\n\u2022 Communicate with PC by USB2.0. The software has a rich re-develop platform which can run on Win7, Win8, Win10, Win11<br \/>\n\u2022 Optical fiber port is SMA905<\/p>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Optische und elektrische Messungen von Festk\u00f6rperbeleuchtungsprodukten\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"IESNA Standard File Format for the Electronic Transfer of Photometric Data and Related information\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"Farbwiedergabe von wei\u00dfen LED-Lichtquellen\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"Die Messung des Lichtstroms\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"Verfahren zur Messung und Bestimmung der Farbwiedergabeeigenschaften von Lichtquellen\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"Spezifikationen f\u00fcr den Farbort von Festk\u00f6rperleuchtmitteln f\u00fcr elektrische Lampen\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(EU) 2019\/2015<\/a> \"DELEGIERTE VERORDNUNG DER KOMMISSION\".<\/p>\n<p><strong>Typical Application:<br \/>\n<\/strong>The LMS-7000 is for LED color &amp; lumen test. It works with <a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_blank\" rel=\"noopener noreferrer\">Integrationskugel<\/a> and standard lamp as a system: <a href=\"https:\/\/www.lisungroup.com\/products\/led-test-instruments\/ccd-spectroradiometer-integrating-sphere-compact-system.html\" target=\"_blank\" rel=\"noopener\">LPCE-3 CCD Spectroradiometer Integrating Sphere Compact System<\/a>. This system can do the following test.<\/p>\n<p><strong>Messung:<br \/>\n<\/strong>Colorimetric: Chromaticity Coordinate (x, y) and (u, v), Relative Spectral Power Distribution P(\u03bb), Correlated Color Temperature (Tc), Color Rendering Index (Ra, R1 to R15), Color Difference, Dominant Wavelength, Peak Wavelength, Half-bandwidth, Spectral Purity, TM30 (Rf, Rg), CQS<br \/>\nPhotometric: Luminous Flux (Lumen), Luminous Efficiency, Radiant Power, EEI, PAR, PPF<br \/>\nElectrical: Voltage, Current, Power, Power Factor, Harmonic (Optional)<\/p>\n<p><strong>Spezifikation:<br \/>\n<\/strong>\u2022\u00a0Spectral Resolution: \u00b10.2nm<br \/>\n\u2022\u00a0Reproducibility: \u00b10.5nm<br \/>\n\u2022\u00a0Accuracy of Chromaticity Coordinate (\u0394x, \u0394y): \u00b10.003<br \/>\n\u2022 Correlated Color Temperature CCT: 1, 500K ~ 25, 000K, CCT Accuracy:\u00b10.5%<br \/>\n\u2022 High spectral resolution, high sensitivity and excellent reliability<\/p>\n<p><strong>Other Applications:<br \/>\n<\/strong>The LMS-7000 can also work with other accessories. It can be used in the following field and area. Please contact LISUN sales dept for the detail solution and spectroradiometer price.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-1990 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer.jpg\" sizes=\"(max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer.jpg 700w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Application-for-LMS-1000-Fiber-Optic-Spectrometer-400x180.jpg 400w\" alt=\"LMS-7000 CCD Spectroradiometer\" width=\"700\" height=\"315\" title=\"\"><\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-3-ccd-spectroradiometer-integrating-sphere-compact-system-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-3 (LMS-7000) CCD Spectroradiometer Integrating Sphere Compact System \u2013 After-sales Frequently Asked Questions (FAQ)\u00a0<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-3 system were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-7000 spectroradiometer applied with Japanese high-precision CCD detector, which has excellent speed, high stability and high accuracy. \u2022\u00a0The following wavelength range is with 0.8nm FWHM: LMS-7000UV LMS-7000UV-VIS LMS-7000VIS LMS-7000VIS-NIR LMS-7000UV-VIS-NIR 200~400nm 200~800nm 350~950nm 350~1050nm 200~1050nm \u2022 Integration time: 0.5ms to 1,0000ms \u2022 CCD detector is 3648pix which size is 8\u03bcm\u00d7200m\u03bcm \u2022\u00a0SNR (Signal to Noise Ratio) [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3423,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[163],"class_list":["post-2406","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-7000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2406","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/comments?post=2406"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2406\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media\/3423"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media?parent=2406"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/categories?post=2406"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/tags?post=2406"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}