{"id":2455,"date":"2025-06-19T19:35:58","date_gmt":"2025-06-19T11:35:58","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/impulse-test-generator\/"},"modified":"2025-07-01T17:27:49","modified_gmt":"2025-07-01T09:27:49","slug":"impulse-test-generator","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/de\/produkte\/impulse-test-generator\/","title":{"rendered":"IEC60950 Low Voltage Surge Generator"},"content":{"rendered":"<p>Impulse Test Generator SUG-CCITT-A (Circuit 1, 10\/700\u03bcS, according to Figure D.1\/ Table D.1 in IEC 62368-1:2018 Annex D, Figure K.1\/ Tabke K.1 in IEC 60065:2014 Annex K , and Figure N.1\/ Table N.1 in IEC 60950-1:2005 Annex N).<\/p>\n<p><strong>Standard:<\/strong><br \/>\nIEC 62368-1:2018\u00a0\u201cAudio\/video, information and communication technology equipment \u2013 Part 1: Safety requirements\u201d<br \/>\nIEC 60065:2014 \u201cAudio, video and similar electronic apparatus \u2013 Safety requirements\u201d<br \/>\nIEC 60950-1:2005 \u201cInformation technology equipment \u2013 Safety \u2013 Part 1: General requirements\u201d<\/p>\n<p>Circuit reference 1 of Table D.1 generates 10\/700 \u03bcs impulses (10 \u03bcs virtual front time, 700 \u03bcs virtual time to half value) as specified in ITU-T Recommendation K.44 to simulate lightning interference in the TELECOMMUNICATION NETWORK.<\/p>\n<p>&nbsp;<\/p>\n<div id=\"attachment_14323\" class=\"wp-caption aligncenter\" style=\"width: 740px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14323 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-1-2.jpg\" sizes=\"(max-width: 730px) 100vw, 730px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-1-2.jpg 730w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-1-2-400x340.jpg 400w\" alt=\"\" width=\"730\" height=\"621\" aria-describedby=\"caption-attachment-14323\" title=\"\"><\/p>\n<p id=\"caption-attachment-14323\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 62368-1 D.1 Impluse test generators<\/span><\/p>\n<\/div>\n<div id=\"attachment_14324\" class=\"wp-caption aligncenter\" style=\"width: 740px;\">\n<p><img decoding=\"async\" class=\"wp-image-14324 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-2-1.jpg\" sizes=\"(max-width: 730px) 100vw, 730px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-2-1.jpg 730w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-2-1-400x366.jpg 400w\" alt=\"\" width=\"730\" height=\"668\" aria-describedby=\"caption-attachment-14324\" title=\"\"><\/p>\n<p id=\"caption-attachment-14324\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Figure D.2 \u2013 Antenna interface test generator circuit<\/span><\/p>\n<\/div>\n<div id=\"attachment_14325\" class=\"wp-caption aligncenter\" style=\"width: 740px;\">\n<p><img decoding=\"async\" class=\"wp-image-14325 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-2-1.jpg\" sizes=\"(max-width: 730px) 100vw, 730px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-2-1.jpg 730w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-2-1-400x347.jpg 400w\" alt=\"\" width=\"730\" height=\"634\" aria-describedby=\"caption-attachment-14325\" title=\"\"><\/p>\n<p id=\"caption-attachment-14325\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Figure D.3 \u2013 Example of an electronic pulse generator<\/span><\/p>\n<\/div>\n<p><strong>Anmerkung:<\/strong><br \/>\n1. If you also need Circuit 2, 1.2\/50\u03bcS, according to Figure D.1\/ Table D.1 in IEC 62368-1:2018 Annex D (Or Figure K.1\/ Tabke K.1 in IEC 60065:2014 Annex K , and Figure N.1\/ Table N.1 in IEC 60950-1:2005 Annex N), it will be <strong>SUG255XX<\/strong> imuplse voltage generator<br \/>\n2. If you also need Circuit 3, according to Figure D.2\/ Table D.1 in IEC 62368-1:2018 Annex D (Or Figure N.2\/Table N.1 in IEC 60950-1:2005 Annex N), it will be <strong>SUG255CX<\/strong> imuplse voltage generator<\/p>","protected":false},"excerpt":{"rendered":"<p>Impulse Test Generator SUG-CCITT-A (Circuit 1, 10\/700\u03bcS, according to Figure D.1\/ Table D.1 in IEC 62368-1:2018 Annex D, Figure K.1\/ Tabke K.1 in IEC 60065:2014 Annex K , and Figure N.1\/ Table N.1 in IEC 60950-1:2005 Annex N). Standard: IEC 62368-1:2018\u00a0\u201cAudio\/video, information and communication technology equipment \u2013 Part 1: Safety requirements\u201d IEC 60065:2014 \u201cAudio, video [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3707,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[209],"class_list":["post-2455","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-sug-ccitt-a"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2455","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/comments?post=2455"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2455\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media\/3707"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media?parent=2455"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/categories?post=2455"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/tags?post=2455"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}