{"id":2504,"date":"2025-06-19T19:36:21","date_gmt":"2025-06-19T11:36:21","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/uv-lamp-test-system\/"},"modified":"2025-06-25T18:06:55","modified_gmt":"2025-06-25T10:06:55","slug":"uv-lamp-test-system","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/de\/produkte\/uv-lamp-test-system\/","title":{"rendered":"UV Lamp Test System"},"content":{"rendered":"<p>The LPCE-2(LMS-9000CUV) UV Lamp Test System is used to test Spectrum, Radiant, Efficiency, UVA, UVB, UVC radiant and electric parameters of the UV lamp (light source). Please click here to see the test report sample: <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/UVA-365nm-Spectral-Radiance.pdf\" target=\"_blank\" rel=\"noopener\">UVA Lamp Spectral-Radiance Test Report<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/UVB-297nm-Spectral-Radiance.pdf\" target=\"_blank\" rel=\"noopener\">UVB Lamp Spectral-Radiance Test Report<\/a> Und <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/UVC-254nm-Spectral-Radiance.pdf\" target=\"_blank\" rel=\"noopener\">UVC Lamp Spectral-Radiance Test Report<\/a>. The system configuration is as follows:<\/p>\n<p><strong>1. LMS-9000CUV High Precision UV Spectroradiometer\uff1a<br \/>\n<\/strong><strong>Messung:<br \/>\n<\/strong>Peak Wavelength, Relative Spectral Power Distribution, Radiant Power, ect.<\/p>\n<p><strong>2. CFS-1.5M Silica Fiber<\/strong><br \/>\nMainly used for optical signal transmission between LMS-9000CUV spectroradiometer and dark case.<\/p>\n<p><strong>3. CASE-UV036 Dark Case for UV Test<\/strong><br \/>\nProvide testing environment for UV light source. The internal dimensions is 60*60*100cm<\/p>\n<p><strong>4. CLAMP-2B Multi-function LED Clamps Set for UV Test including movable rail (Optional)<br \/>\n<\/strong>CLAMP-2B is suitable for most SMD and through-hole single UV light sources test, it can move on the 60~316mm rail (the movable rail has been built-in the CASE-UV036 Dark Case) to test various UV light sources with different light intensities.<\/p>\n<div id=\"attachment_14440\" class=\"wp-caption aligncenter\" style=\"width: 580px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14440 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/CLAMP-2b.png\" sizes=\"(max-width: 570px) 100vw, 570px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/CLAMP-2b.png 570w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/CLAMP-2b-400x368.png 400w\" alt=\"\" width=\"570\" height=\"524\" aria-describedby=\"caption-attachment-14440\" title=\"\"><\/p>\n<p id=\"caption-attachment-14440\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">CASE-UV036 Dark Case for UV Test and CLAMP-2B Multi-function LED Clamps Set (including movable rail)<\/span><\/p>\n<\/div>\n<p><strong>5. SLS-UV UV Standard Lamp with Power Supply<\/strong><br \/>\nThe UV spectrum calibration system includes a UV standard lamp and a Special power supply. The standard lamp is a deuterium light source. Deuterium lamp spectrum is continuous, and it is an ideal UV light source for photometric analysis instruments. In order to ensure the stability of the light source and prolong its service life, the standard light source is equipped with a special power supply.<\/p>\n<div id=\"attachment_13378\" class=\"wp-caption aligncenter\" style=\"width: 410px;\">\n<p><img decoding=\"async\" class=\"wp-image-13378 size-medium\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/SLS-UV_AL-400x400.jpg\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/SLS-UV_AL-400x400.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/SLS-UV_AL-1080x1080.jpg 1080w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/SLS-UV_AL-100x100.jpg 100w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/SLS-UV_AL-768x768.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/03\/SLS-UV_AL.jpg 1200w\" alt=\"UV Standard Light Source with Power Supply\" width=\"400\" height=\"400\" aria-describedby=\"caption-attachment-13378\" title=\"\"><\/p>\n<p id=\"caption-attachment-13378\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">UV Standard Light Source with Power Supply<\/span><\/p>\n<\/div>\n<p><strong>Spezifikation:<\/strong><b><br \/>\n<\/b><span style=\"vertical-align: inherit;\">- <\/span><span lang=\"EN-US\">Preheating voltage: 2.5V<br \/>\n<\/span><span style=\"vertical-align: inherit;\">- <span lang=\"EN-US\">P<\/span><span lang=\"EN-US\">reheating current: <\/span><\/span><span lang=\"EN-US\">4A<br \/>\n<\/span><span style=\"vertical-align: inherit;\">\u2022 Trigger voltage: <\/span><span lang=\"EN-US\">350V<br \/>\n<\/span><span style=\"vertical-align: inherit;\">\u2022 Lamp current: <\/span><span lang=\"EN-US\">300mA<br \/>\n<\/span><span style=\"vertical-align: inherit;\">- <\/span>Wavelength range: <span lang=\"EN-US\">200~400nm<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>The LPCE-2(LMS-9000CUV) UV Lamp Test System is used to test Spectrum, Radiant, Efficiency, UVA, UVB, UVC radiant and electric parameters of the UV lamp (light source). Please click here to see the test report sample: UVA Lamp Spectral-Radiance Test Report, UVB Lamp Spectral-Radiance Test Report and UVC Lamp Spectral-Radiance Test Report. The system configuration is [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3434,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[257],"class_list":["post-2504","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lpce-2lms-9000cuv"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2504","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/comments?post=2504"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2504\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media\/3434"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media?parent=2504"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/categories?post=2504"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/tags?post=2504"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}