{"id":2561,"date":"2025-06-19T19:36:57","date_gmt":"2025-06-19T11:36:57","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/coupling-decoupling-network-for-power-lines\/"},"modified":"2025-06-25T17:34:15","modified_gmt":"2025-06-25T09:34:15","slug":"coupling-decoupling-network-for-power-lines","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/de\/produkte\/coupling-decoupling-network-for-power-lines\/","title":{"rendered":"Coupling Decoupling Network for Power Lines"},"content":{"rendered":"<p>The CDN61000-5P Series Coupling Decoupling Network for Power Lines are used to work with LISUN <a href=\"https:\/\/www.lisungroup.com\/products\/emi-and-emc-test-system\/surge-generator.html\" target=\"_blank\" rel=\"noopener\">SG61000-5 series Surge Generator<\/a> Und <a href=\"https:\/\/www.lisungroup.com\/products\/emi-and-emc-test-system\/ring-wave-generator.html\" target=\"_blank\" rel=\"noopener\">RWG61000-12 series Ring Wave Generator<\/a>. It can do the three-phases power line surge immunity test.<\/p>\n<p><strong>Standard\uff1a<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC61000-4-12-2006-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC61000-4-12<\/a>\/EN61000-4-12\/<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-17626.12-1998-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T17626.12<\/a>\u00a0\u201cElektromagnetische Vertr\u00e4glichkeit (EMV) \u2013 Teil 4-12: Pr\u00fcfung und Messung \u2013 St\u00f6rfestigkeitspr\u00fcfung gegen Ringwellen\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/iec-61000-4-5-surge-test-and-measurement-techniques.html\" data-cke-saved-href=\"https:\/\/lisungroup.com\/article-id-72.html\" target=\"_blank\" rel=\"noopener\">IEC 61000-4-5\/<\/a><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/EN61000-4-5-1995-Standard-Free-Download.pdf\" data-cke-saved-href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/EN61000-4-5-1995-Standard-Free-Download.pdf\" data-cke-saved- target=\"_blank\" rel=\"noopener\">EN61000-4-5\/<\/a><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GB%E2%88%95T17626.5-2019-Standard-Free-Lownload.pdf\" data-cke-saved-href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GB%E2%88%95T17626.5-2019-Standard-Free-Lownload.pdf\" data-cke-saved- target=\"_blank\" rel=\"noopener\">GB\/T17626.5<\/a>\u00a0\u201eElektromagnetische Vertr\u00e4glichkeit (EMV) \u2013 Teil 4-5: Pr\u00fcf- und Messverfahren \u2013 Pr\u00fcfung der St\u00f6rfestigkeit gegen Sto\u00dfspannungen\u201c<\/p>\n<table style=\"width: 100.019%;\">\n<tbody>\n<tr>\n<td style=\"text-align: center; vertical-align: middle; width: 21.5282%;\" width=\"140\"><strong><b>LISUN-Modell<\/b><\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle; width: 24.5407%;\" width=\"188\"><strong><b>CDN61000-5P-T440V20A<\/b><\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle; width: 26.3448%;\" width=\"188\"><strong><b>CDN61000-5P-T440V32A<\/b><\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle; width: 48.9546%;\" width=\"188\"><strong><b>CDN61000-5P-T440V100A<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle; width: 21.5282%;\" width=\"140\">Coupling \u00a0Wave<\/td>\n<td style=\"text-align: center; vertical-align: middle; width: 99.8401%;\" colspan=\"3\" width=\"564\">IEC61000-4-5 Surge Combine Wave 1.2\/50\u03bcs and 8\/20\u03bcs\uff0cIEC61000-4-12 Ring Wave<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle; width: 21.5282%;\" width=\"140\">Max Surge Voltage\/Current<\/td>\n<td style=\"text-align: center; vertical-align: middle; width: 99.8401%;\" colspan=\"3\" width=\"564\">6KV\/3KA (Work with LISUN SG61000-5 series Surge Generator or RWG61000-12 series Ring Wave Generator)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle; width: 21.5282%;\" width=\"140\">Phase Angle<\/td>\n<td style=\"text-align: center; vertical-align: middle; width: 99.8401%;\" colspan=\"3\" width=\"564\">Asynchronous, Synchronization 0\u00b0~ 360\u00b0<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle; width: 21.5282%;\" width=\"140\">Coupling Mode<\/td>\n<td style=\"text-align: center; vertical-align: middle; width: 99.8401%;\" colspan=\"3\" width=\"564\">Common-Mode and Differential-Mode<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle; width: 21.5282%;\" width=\"140\">EUT Capacity<\/td>\n<td style=\"text-align: center; vertical-align: middle; width: 24.5407%;\" width=\"188\">3phases\/AC440V\/20A<\/td>\n<td style=\"text-align: center; vertical-align: middle; width: 26.3448%;\" width=\"188\">3phases\/AC440V\/32A<\/td>\n<td style=\"text-align: center; vertical-align: middle; width: 48.9546%;\" width=\"188\">3phases\/AC440V\/100A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"attachment_11632\" class=\"wp-caption aligncenter\" style=\"width: 410px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-11632\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/07\/CDN61000-5P_AL0-1-400x400.jpg\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/07\/CDN61000-5P_AL0-1-400x400.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/07\/CDN61000-5P_AL0-1-1080x1080.jpg 1080w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/07\/CDN61000-5P_AL0-1-100x100.jpg 100w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/07\/CDN61000-5P_AL0-1-768x768.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/07\/CDN61000-5P_AL0-1.jpg 1200w\" alt=\"\" width=\"400\" height=\"400\" aria-describedby=\"caption-attachment-11632\" title=\"\"><\/p>\n<p id=\"caption-attachment-11632\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">CDN61000-5P Coupling Decoupling Network for Power Lines<\/span><\/p>\n<\/div>\n<p>Note: It can be customized according to customer requirements. For example, CDN61000-5PH-T1000V50A has a Max input voltage of 10KV and Max input current of 5KA, and the capacity of the equipment under test (EUT) is 3phases\/AC1000V\/50A, which can be worked with LISUN SG61000-5H-SP.<\/p>","protected":false},"excerpt":{"rendered":"<p>The CDN61000-5P Series Coupling Decoupling Network for Power Lines are used to work with LISUN SG61000-5 series Surge Generator and RWG61000-12 series Ring Wave Generator. It can do the three-phases power line surge immunity test. Standard\uff1a IEC61000-4-12\/EN61000-4-12\/GB\/T17626.12\u00a0\u201cElectromagnetic compatibility (EMC) \u2013 Part 4-12: Testing and measuring \u2013 Ring waves immunity test\u201d IEC 61000-4-5\/EN61000-4-5\/GB\/T17626.5\u00a0\u201cElectromagnetic compatibility (EMC) \u2013 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3163,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[314],"class_list":["post-2561","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-cdn61000-5p"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2561","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/comments?post=2561"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2561\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media\/3163"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media?parent=2561"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/categories?post=2561"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/tags?post=2561"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}