{"id":2901,"date":"2025-06-19T19:42:03","date_gmt":"2025-06-19T11:42:03","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60245-1-clause-5-1-5-iec-60245-2-clause-2-1-iec-60468-universal-conductor-resistor-fixture\/"},"modified":"2025-07-01T17:07:15","modified_gmt":"2025-07-01T09:07:15","slug":"iec-60245-1-clause-5-1-5-iec-60245-2-clause-2-1-iec-60468-universal-conductor-resistor-fixture","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/de\/produkte\/iec-60245-1-clause-5-1-5-iec-60245-2-clause-2-1-iec-60468-universal-conductor-resistor-fixture\/","title":{"rendered":"LCR digital bridge can test C,R,L,Z,D,Q"},"content":{"rendered":"<p>The LS-B43 Universal Conductor Resistance Fixture is designed and manufactured in full accordance with the provisions of IEC 60245-1:2008 Clause 5.1.5 (GB\/T 5013.1-2008 Clause 5.1.5), IEC 60245-2:1998 Clause 2.1 (GB\/T 5013.2-2008 Clause 2.1) and IEC 60468:1974. It is suitable for measuring the DC resistance of various power cables and electrical equipment wires and cables, and can also be used to measure the DC resistance of other conductor materials.<\/p>\n<p>Testing principle: It employs a quick clamping and release mechanism using a forward and reverse screw structure. The voltage and current clamps are separated to improve the contact points with the sample. The fixture is built with an aluminum alloy base and copper clamps.<\/p>\n<p><strong>Standard:<\/strong><br \/>\nIEC 60245-1 (GB\/T 5013.1) \u201cRubber insulated cables \u2013 Rated voltages up to and including 450\/750 V \u2013 Part 1: General requirements\u201d Clause 5.1.5<br \/>\nIEC 60245-2 (GB\/T 5013.2) \u201cRubber insulated cables \u2013 Rated voltages up to and including 450\/750 V \u2013 Part 2: Test methods\u201d Clause 2.1<br \/>\nIEC 63294 \u201cTest methods for electric cables with rated voltages up to and including 450\/750 V\u201d<br \/>\nIEC 60468 \u201cMethod of measurement of resistivity of metallic materials\u201d<\/p>\n<p><strong>Spezifikation:<\/strong><\/p>\n<table style=\"width: 100.339%; height: 48px;\" width=\"605\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\" width=\"272\">Distance between two voltage clamps<\/td>\n<td style=\"height: 24px;\" width=\"333\">100~1000 mm<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"height: 24px;\" width=\"272\">Compatible LCR bridge<\/td>\n<td style=\"height: 24px;\" width=\"333\"><a href=\"https:\/\/www.lisungroup.com\/products\/electronic-components-test\/lcr-digital-bridge.html\" target=\"_blank\" rel=\"noopener\">LISUN FD2811C LCR Digital Bridge (Optional)<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"attachment_15450\" class=\"wp-caption aligncenter\" style=\"width: 615px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-15450 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/10\/IEC-60245-2-Clause-2.1.png\" sizes=\"(max-width: 605px) 100vw, 605px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/10\/IEC-60245-2-Clause-2.1.png 605w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/10\/IEC-60245-2-Clause-2.1-400x196.png 400w\" alt=\"\" width=\"605\" height=\"297\" aria-describedby=\"caption-attachment-15450\" title=\"\"><\/p>\n<p id=\"caption-attachment-15450\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60245-2 Clause 2.1<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The LS-B43 Universal Conductor Resistance Fixture is designed and manufactured in full accordance with the provisions of IEC 60245-1:2008 Clause 5.1.5 (GB\/T 5013.1-2008 Clause 5.1.5), IEC 60245-2:1998 Clause 2.1 (GB\/T 5013.2-2008 Clause 2.1) and IEC 60468:1974. It is suitable for measuring the DC resistance of various power cables and electrical equipment wires and cables, and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3485,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[595],"class_list":["post-2901","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls-b43"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2901","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/comments?post=2901"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/posts\/2901\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media\/3485"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/media?parent=2901"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/categories?post=2901"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/de\/wp-json\/wp\/v2\/tags?post=2901"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}