Gauge for Outlets 16A 250V A.C. of IEC 60906-1 Figure 2

N.º de producto:

Dejar un mensaje

=

Gauge for Outlets 16A 250V A.C. of IEC 60906-1 Figure 2

Dejar un mensaje

=
Descripción del Producto

During the tests using these gauges, shutters shall be held open.

The metallic parts of gauges A, B and C are made of hard corrosion-resistant metal (e.g. stainless steel).

An electrical indicator with a voltage not less than 40V and not more than 50 V is used to show contact.

The gauge A shall be introduced through the entry holes of the socket-contactassembly in every possible position until the plane XX is fully in contact with the engagement face.

The indicator shall not light.

The pins of gauges B and C shall be completely inserted. Then,
– for gauge B the indicator shall light;
– for gauge C the indicator shall not light.

IEC 60906-1 Figure 2