1200-hour Moist Carbon Dioxide-Sulfur Dioxide-air Test Chamber

N.º de producto:

Dejar un mensaje

=

1200-hour Moist Carbon Dioxide-Sulfur Dioxide-air Test Chamber

Dejar un mensaje

=
Descripción del Producto

The SQCO-300 mixed gas corrosion test chamber uses two gases, sulfur dioxide (SO₂) and carbon dioxide (CO₂), to accelerate the corrosion of materials or products in a certain temperature environment. It can reproduce the degree of damage that materials or products suffer within a certain period of time. This test chamber is also useful for comparing the process quality of similar protective layers, evaluating the corrosion resistance of protective layers of components, electronic components, metal materials, electrical and electronic products, as well as industrial products in the mixed gas environment.

The SQCO-300 mixed gas corrosion test chamber can heat the test working space to the specified temperature and maintain it constantly. A certain amount of corrosive gases are introduced into the chamber with a specified volume, and when the gas concentration reaches the standard, the corrosion test on materials or products can be carried out.

Especificación:

NormasUL 50E: 2015 Clause 8.8.2
Dimensiones300L (internal dimensions: 900*600*550mm, external dimensions: 1400*730*1550mm)
Test Environment ConditionsThe air around the equipment should be smooth, with no high – concentration dust, no corrosive or flammable and explosive gases. 
Ambient temperature: 5~30℃ Relative humidity: ≤85%RH
Rango de temperatura20℃~50℃(Adjustable)
Temperature Uniformity≤±2℃
Fluctuación de temperatura≤±0.5℃
Temperature Resolution0.01℃
Humidity Generation MethodBottom water tank type (10ml/0.0003m³)
Sulfur Dioxide Concentration0.1%~1% (volume percentage)
Carbon Dioxide Concentration0.1%~1% (volume percentage)
Gas Generation MethodCylinder Method
Concentration Measurement MethodCalculate the volume ratio through formulas and then measure with an anti – corrosion mass flow meter. The gas flow value can be set on the controller.
Gas FlowUse anti-corrosion mass flow meter  according to test requirements (adjustable)
Test Time~9999 hours (Adjustable)
PowerSingle-phase 220V (110V can be customized), 2kW
 

Estándar:
UL 50E “Standard for Safety. Enclosures for Electrical Equipment, Environmental Considerations” Clause 8.8.2

UL 50E:2015 Clause 8.8.2