LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84CIE-13.3, IES LM-79-24, IES LM-79-19, Optical-Engineering-49-3-033602, REGLAMENTO DELEGADO (UE) 2019/2015 DE LA COMISIÓN, IESNA LM-63-2, IES-LM-80 y ANSI-C78.377, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS-9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and a-molding integrating sphere with holder base. This sphere is more round and the test result is more accruate than the traditional integrating sphere.

Estándar:
CIE 177 "Reproducción cromática de fuentes de luz LED blancas"
CIE84 "La medición del flujo luminoso"
CIE-13.3 "Método de medición y especificación de las propiedades de reproducción cromática de las fuentes luminosas"
LM-79-19 "Mediciones ópticas y eléctricas de productos de iluminación de estado sólido"
IESNA LM-63-2 "Formato de archivo estándar IESNA para la transferencia electrónica de datos fotométricos e información relacionada"
IES LM-80-08 “Measuring Lumen Maintenance of LED Light Sources”
ANSI-C78.377 "Especificaciones de cromaticidad de los productos de iluminación de estado sólido para lámparas eléctricas"
(UE) 2019/2015 "REGLAMENTO DELEGADO DE LA COMISIÓN"

Medición:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, WPE, EQE, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF
• Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic(Optional)
• LED Light Aging Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.

Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MT Esfera integradora de temperatura constante y TMP-8 Multiplex Temperature Tester can fully meet IES LM-82

High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufacturer or General Test Lab):
High Precision CCD Spectroradiometer (LMS-9000C), Fibra óptica (CFO-1,5M), Medidor de potencia digital (LS2050B/LS2050C/LS2012), Fuente de alimentación CC (DC Series), Fuente de alimentación de CA (LSP-500VARC or LSP-500VARC-Pst), Esfera Integradora (IS-1.5MA and IS-0.3M), Fuente de luz estándar (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detailed PDF here: LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure

Especificación:
• Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm
- Pasos de exploración de muestras: ±0,1 nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (under Standard A Lamp)
• Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5%
• Stray light: <0.015%(600nm) and <0.03%(435nm)
• Integration Time: 0.1~10,000ms
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
- El sistema incluye un dispositivo de lámpara auxiliar y el software incluye la función de corrección del coeficiente de autoabsorción
• It can measure the temperatures inside and outside of integrating sphere
- Conectar con PC mediante cable USB. El software de la versión en inglés puede funcionar en Win7, Win8, Win10, Win11 (controlador certificado por Microsoft).
• The LM-79 Photometry, Colorimetry and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

Modelo LISUN LMS-9000C LMS-9000CUV-VIS LMS-9000CVIS-NIR
Wavelength 350-800nm 200-800nm 350-1050nm

Scientific Grade LPCE-2(LMS-9500C) System Configuration (It is suitable for the Big & Middle Manufactory or Third Party Test Lab): 
Scientific Grade CCD Spectroradiometer (LMS-9500C), Fibra óptica (CFO-1,5M), Medidor de potencia digital (LS2050C), Fuente de alimentación CC (DC Series), Fuente de alimentación de CA (LSP-500VARC or LSP-500VARC-Pst), Esfera Integradora (IS-1.5MA and IS-0.3M), Fuente de luz estándar (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9500C) Scientific Grade CCD Spectroradiometer Integrating Sphere System Brochure

Especificación:
• CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector
• Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Sample scanning steps: ±0.1nm
• Accuracy of chromaticity coordinate (Δx, Δy): ±0.0015 (under Standard A Lamp)
• Correlated color temperature CCT: 1, 500K~100, 000K, CCT accuracy: ±0.2%
• Color rendering index range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear Accuracy: ±0.2%
• Stray light: <0.015%(600nm) and <0.03% (435nm)
• Integration time: 0.1ms-60s
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
- El sistema incluye un dispositivo de lámpara auxiliar y el software incluye la función de corrección del coeficiente de autoabsorción
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10, Win11 (Microsoft certified driver)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

Modelo LISUN LMS-9500C LMS-9500CUV-VIS LMS-9500CVIS-NIR
Wavelength 350-800nm 200-800nm 350-1050nm

LISUN LPCE-2(LMS-9000C) High Precision Spectroradiometer Integrating Sphere System – After-sales Frequently Asked Questions (FAQ).
LISUN LPCE-2(LMS-9000C) High Precision Spectroradiometer Integrating Sphere System were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.

LISUN LPCE-2(LMS-9500C) High Precision Spectroradiometer Integrating Sphere System – After-sales Frequently Asked Questions (FAQ).
LISUN LPCE-2(LMS-9500C) High Precision Spectroradiometer Integrating Sphere System were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.

LISUN LPCE-2(LMS-9000B/A) High Precision Spectroradiometer Integrating Sphere System – After-sales Frequently Asked Questions (FAQ).
LISUN LPCE-2(LMS-9000B/A) High Precision Spectroradiometer Integrating Sphere System were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.