{"id":2333,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/goniophotometer-with-rotating-mirror\/"},"modified":"2025-06-27T10:24:48","modified_gmt":"2025-06-27T02:24:48","slug":"goniophotometer-with-rotating-mirror","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/es\/productos\/goniophotometer-with-rotating-mirror\/","title":{"rendered":"Goniophotometer with Rotating Mirror"},"content":{"rendered":"<p>LSG-2000 <a href=\"https:\/\/www.lisungroup.com\/products\/goniophotometer\/\" target=\"_blank\" rel=\"noopener\">Goniofot\u00f3metro<\/a> with Rotating Mirror is also called the Moving Mirror Goniophotometer. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The darkroom can be designed according to the customer\u2019s existing room size. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.<\/p>\n<div id=\"attachment_3595\" class=\"wp-caption aligncenter\" style=\"width: 2011px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-3595 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle.jpg\" sizes=\"(max-width: 2001px) 100vw, 2001px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle.jpg 2001w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle-400x117.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle-768x225.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000-moving-mirror-goniophotometer-principle-1920x562.jpg 1920w\" alt=\"\" width=\"2001\" height=\"586\" aria-describedby=\"caption-attachment-3595\" title=\"\"><\/p>\n<p id=\"caption-attachment-3595\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">LSG-2000 Moving Mirror Goniophotometer Principle<\/span><\/p>\n<\/div>\n<div id=\"product-tab\" class=\"woocommerce-tabs woocommerce-tabs-mnuoobsanjog9tqcdrnax9f3ei9bm4g\">\n<div class=\"resp-tabs-container\">\n<div id=\"tab-description\" class=\"tab-content resp-tab-content resp-tab-content-active\" aria-labelledby=\"tab_item-0\">\n<div id=\"attachment_6328\" class=\"wp-caption aligncenter\" style=\"width: 2049px;\">\n<p><img decoding=\"async\" class=\"wp-image-6328 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1.jpg\" sizes=\"(max-width: 2039px) 100vw, 2039px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1.jpg 2039w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1-400x117.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1-768x224.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-2000_YK1-1920x561.jpg 1920w\" alt=\"LSG-2000 Moving Detector Goniophotometer Dark Room\" width=\"2039\" height=\"596\" aria-describedby=\"caption-attachment-6328\" title=\"\"><\/p>\n<p id=\"caption-attachment-6328\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">LSG-2000 Moving Detector Goniophotometer Dark Room<\/span><\/p>\n<\/div>\n<p><strong>Medici\u00f3n:<br \/>\n<\/strong>Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution (Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc.<\/p>\n<p><strong>Est\u00e1ndar:<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Mediciones \u00f3pticas y el\u00e9ctricas de productos de iluminaci\u00f3n de estado s\u00f3lido\"<br \/>\n<a href=\"https:\/\/www.lisungroup.cn\/wp-content\/uploads\/2019\/07\/EN13032-1-2004AC-2005.pdf\" target=\"_blank\" rel=\"noopener\">EN13032-1<\/a> \"Luz e iluminaci\u00f3n. Medici\u00f3n y presentaci\u00f3n de datos fotom\u00e9tricos de l\u00e1mparas y luminarias: Medici\u00f3n y formato de fichero; versi\u00f3n alemana EN 13032-1:2004+A1:2012\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"Medici\u00f3n del mantenimiento del lumen de las fuentes de luz LED\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CIE-121-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-121<\/a> \u201cThe Photometry and Goniophotometry of Luminaires\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-70-1987-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-70 <\/a>\u00a0\u201cThe Measurement of Absolute Luminous Intensity Distribution\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESNA_LM-75-2001-Goniophotometer-Types-and-Photometric-Coordinates.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-75<\/a>\u00a0 \"Goniofot\u00f3metroTipos y coordenadas fotom\u00e9tricas\"<\/p>\n<p><strong>Features:<\/strong><br \/>\n- El motor rotativo es de Jap\u00f3n MITSUBISHI MOTORS y el sistema de decodificaci\u00f3n de \u00e1ngulos es de Alemania. Ayudan a que el goniofot\u00f3metro gire suavemente con alta precisi\u00f3n. Es muy estable cuando se inicia y se detiene.<br \/>\n\u2022 The working principles are according to IESNA and CIE. The LSG-2000 completely meets the <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESLM-79-LM-80-Chinese-Version-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">LM-80<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESNA_LM-75-2001-Goniophotometer-Types-and-Photometric-Coordinates.pdf\" target=\"_blank\" rel=\"noopener\">LM-75<\/a>, GB, EN13032-1 and <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CIE-121-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE121-1996<\/a> normas.<br \/>\n\u2022 Special collimation device with laser cross line help you installaing the position of luminaires undertest conveniently and accurately.<\/p>\n<p><strong>Especificaciones:<\/strong><br \/>\n\u2022 The mirror rotates around the luminaire under test with an angle of (\u03b3) \u00b1180\u00b0 (or 0-360\u00b0) and the luminaire rotates around itself with an angle of (C) \u00b1180\u00b0 (or 0-360\u00b0).<br \/>\n- Precisi\u00f3n del \u00e1ngulo: 0,05\u00b0, Resoluci\u00f3n del \u00e1ngulo: 0,001\u00b0.<br \/>\n\u2022 Accuracy of\u00a0<a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/photo-detector.html\" target=\"_blank\" rel=\"noopener\">fotodetector<\/a>: Constant temperature\u00a0<a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/photo-detector.html\" target=\"_blank\" rel=\"noopener\">fotodetector<\/a>\u00a0DIN5032-6\/CIE pub1. N\u00ba 69 Clase L<br \/>\n- El software del goniofot\u00f3metro LISUN puede exportar archivos CIE, IES, LDT y otros formatos. Estos tipos de archivos de formato se pueden utilizar a trav\u00e9s de otro software de iluminaci\u00f3n y dise\u00f1o de luminarias como DiaLux.<br \/>\n\u2022 Connect goniophotometer to PC via USB cable. English version software can run on Win7, Win8, Win10 Win11.<br \/>\n\u2022 LSG-2000 can be used together with a USB CCD Spectrometer to test spatial CCT Distribution and other Spectral color parameters. We call this system \u201cGoniospectroradiometer (LSG-2000CCD)\u201d. Please download the brochure for LSG-2000CCD.<\/p>\n<table style=\"width: 94.1357%;\" border=\"1\" width=\"1144\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td style=\"width: 19.2476%;\">Modelo LISUN<\/td>\n<td style=\"width: 17.3997%;\">LSG-2000B (Big Size)<\/td>\n<td style=\"width: 18.5855%;\">LSG-2000 (Standard Size)<\/td>\n<td style=\"width: 18.6096%;\">LSG-2000S (Small Size)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19.2476%;\">Measure Non-Flood Lamp<\/td>\n<td style=\"width: 17.3997%;\">\u03a6 1600*800mm, 50kg<\/td>\n<td style=\"width: 18.5855%;\">\u03a6 1400*500mm, 40kg<\/td>\n<td style=\"width: 18.6096%;\">\u03a6 1000*460mm, 30kg<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19.2476%;\">Measure Flood Lamp<\/td>\n<td style=\"width: 17.3997%;\">600*600mm, 50kg<\/td>\n<td style=\"width: 18.5855%;\">600*600mm, 40kg<\/td>\n<td style=\"width: 18.6096%;\">400*400mm, 30kg<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19.2476%;\">Medida Potencia (W)<\/td>\n<td style=\"width: 17.3997%;\">600V\/10A, AC\/DC<\/td>\n<td style=\"width: 18.5855%;\">600V\/10A, AC\/DC<\/td>\n<td style=\"width: 18.6096%;\">600V\/10A, AC\/DC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>LSG-2000 Goniophotometer with Rotating Mirror is also called the Moving Mirror Goniophotometer. The LSG-2000 is an automatic light distribution intensity 3D curve testing system. The darkroom can be designed according to the customer\u2019s existing room size. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":410,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[91],"class_list":["post-2333","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lsg-2000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts\/2333","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/comments?post=2333"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts\/2333\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/media\/410"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/media?parent=2333"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/categories?post=2333"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/tags?post=2333"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}