{"id":2380,"date":"2025-06-19T19:35:13","date_gmt":"2025-06-19T11:35:13","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/scientific-grade-ccd-spectroradiometer\/"},"modified":"2025-06-27T14:05:44","modified_gmt":"2025-06-27T06:05:44","slug":"scientific-grade-ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/es\/productos\/scientific-grade-ccd-spectroradiometer\/","title":{"rendered":"Espectrorradi\u00f3metro CCD de calidad cient\u00edfica"},"content":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray light control technology, wide dynamic linear technology, precision CCD electronic drive technology and complex matrix software technology. The instrument is traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST standards.<\/p>\n<p><strong>Est\u00e1ndar<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"Reproducci\u00f3n crom\u00e1tica de fuentes de luz LED blancas\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"La medici\u00f3n del flujo luminoso\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"M\u00e9todo de medici\u00f3n y especificaci\u00f3n de las propiedades de reproducci\u00f3n crom\u00e1tica de las fuentes luminosas\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Mediciones \u00f3pticas y el\u00e9ctricas de productos de iluminaci\u00f3n de estado s\u00f3lido\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"Formato de archivo est\u00e1ndar IESNA para la transferencia electr\u00f3nica de datos fotom\u00e9tricos e informaci\u00f3n relacionada\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"Medici\u00f3n del mantenimiento del lumen de las fuentes de luz LED\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"Especificaciones de cromaticidad de los productos de iluminaci\u00f3n de estado s\u00f3lido para l\u00e1mparas el\u00e9ctricas\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(UE) 2019\/2015<\/a> \"REGLAMENTO DELEGADO DE LA COMISI\u00d3N\"<\/p>\n<p><strong>Especificaci\u00f3n:<\/strong><br \/>\n\u2022 CCD detector: Hamamatsu TE-cooled (Temp: -10\u00b0C \u00b10.05\u00b0C) high sensitivity back-thinned detector (LMS-9500CSWIR uses InGaAs)<br \/>\n- Precisi\u00f3n de la longitud de onda espectral: \u00b10,2 nm, Resoluci\u00f3n: \u00b10,1 nm, Pasos de exploraci\u00f3n de la muestra: \u00b10,1 nm<br \/>\n- Precisi\u00f3n de la coordenada de cromaticidad (\u0394x, \u0394y): \u00b10,0015 (con l\u00e1mpara est\u00e1ndar A)<br \/>\n- Temperatura de color correlacionada CCT: 1, 500K~100, 000K, precisi\u00f3n CCT: \u00b10,2%<br \/>\n- Rango del \u00edndice de reproducci\u00f3n crom\u00e1tica: 0~100,0, Precisi\u00f3n: \u00b1(0,3%rd\u00b10,3)<br \/>\n\u2022 Photometric linear: \u00b10.2%, Stray light: &lt;0.015%(600nm) and &lt;0.03% (435nm)<br \/>\n- Tiempo de integraci\u00f3n: 0,1 ms-60 s<br \/>\n- Puede medir las temperaturas dentro y fuera de la esfera integradora<br \/>\n\u2022 Flux testing method: spectrum, photometric, spectrum with photometric revision<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 20%;\"><strong>Modelo LISUN<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500C<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CUV-VIS<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CVIS-NIR<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CSWIR<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 20%;\"><strong>Longitud de onda<\/strong><\/td>\n<td style=\"width: 20%;\">350-800nm<\/td>\n<td style=\"width: 20%;\">200-800nm<\/td>\n<td style=\"width: 20%;\">350-1050nm<\/td>\n<td style=\"width: 20%;\">800-1700nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9500b-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html \" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">Sistema de Esfera Integradora para Espectrorradi\u00f3metro de Alta Precisi\u00f3n LISUN LPCE-2(LMS-9500C) - Preguntas frecuentes postventa (FAQ).<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-2(LMS-9500C) Espectrorradi\u00f3metro de Alta Precisi\u00f3n Sistema de Esfera Integradora han estado en el mercado durante m\u00e1s de 10 a\u00f1os, el equipo de servicio de ingenieros de LISUN ya ha resumido la mayor\u00eda de las preguntas y respuestas de postventa en el enlace anterior. Por favor, l\u00e9alo atentamente, puede resolver la mayor\u00eda de los problemas por s\u00ed mismo si tiene algunas preguntas durante el uso de los instrumentos. LISUN seguir\u00e1 actualizando estas p\u00e1ginas y podr\u00e1 encontrar m\u00e1s preguntas frecuentes en este enlace.<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB\/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4774,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[137],"class_list":["post-2380","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-9500c"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts\/2380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/comments?post=2380"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts\/2380\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/media\/4774"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/media?parent=2380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/categories?post=2380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/tags?post=2380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}