{"id":2461,"date":"2025-06-19T19:35:58","date_gmt":"2025-06-19T11:35:58","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/ring-wave-generator\/"},"modified":"2025-07-01T17:26:59","modified_gmt":"2025-07-01T09:26:59","slug":"generador-de-ondas-en-anillo","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/es\/productos\/generador-de-ondas-en-anillo\/","title":{"rendered":"IEC61000-4-12 Generador de ondas en anillo"},"content":{"rendered":"<p>El generador de pruebas de onda anular est\u00e1 dise\u00f1ado de acuerdo con el <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC61000-4-12-2006-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC61000-4-12<\/a>, EN61000-4-12, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C62.41-1991-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C62-41<\/a> y <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-17626.12-1998-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T17626.12.<\/a> Este instrumento se utiliza para la red el\u00e9ctrica de simulaci\u00f3n, la alimentaci\u00f3n de la carga reactiva y el interruptor de la l\u00ednea de control, as\u00ed como la detecci\u00f3n de la onda de anillo del equipo terminal de cables de baja tensi\u00f3n causada por la desconexi\u00f3n del circuito de alimentaci\u00f3n, la aver\u00eda y la rotura del aislamiento o la ca\u00edda de un rayo. Los productos de la serie RWG61000-12 disponen de pantalla LCD en ingl\u00e9s y chino.<\/p>\n<p><strong>Est\u00e1ndar:<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC61000-4-12-2006-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC61000-4-12<\/a>\/EN61000-4-12\/<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-17626.12-1998-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T17626.12<\/a> \"Compatibilidad electromagn\u00e9tica (CEM) - Parte 4-12: Ensayos y medidas - Ensayo de inmunidad a las ondas en anillo\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C62.41-1991-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C62-41<\/a> \"IEEE Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits\" (Pr\u00e1cticas recomendadas del IEEE sobre sobretensiones en circuitos de alimentaci\u00f3n de CA de baja tensi\u00f3n).<\/p>\n<p><strong>Especificaci\u00f3n:<\/strong><\/p>\n<table style=\"width: 99.7929%;\" border=\"1\" width=\"1062\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td style=\"width: 13.5593%;\"><strong>Modelo de producto<\/strong><\/td>\n<td style=\"width: 8.98446%;\"><strong>RWG61000-12<\/strong><\/td>\n<td style=\"width: 12.6513%;\"><strong>RWG61000-12T<\/strong><\/td>\n<td style=\"width: 14.8106%;\"><strong>RWG61000-12A<\/strong><\/td>\n<td style=\"width: 12.9121%;\"><strong>RWG61000-12AT<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.5593%;\">Voltaje de salida<\/td>\n<td style=\"width: 21.6357%;\" colspan=\"2\">0~4KV<\/td>\n<td style=\"width: 27.7227%;\" colspan=\"2\">0~6KV<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.5593%;\">Onda de tensi\u00f3n\/corriente<\/td>\n<td style=\"width: 49.3585%;\" colspan=\"4\">Onda de tensi\u00f3n de circuito abierto: frontera: 0,5\u03bcs\u00b120%. Onda de corriente de cortocircuito: frontera: \u22641\u03bcs. Frecuencia de oscilaci\u00f3n: 100kHz\u00b110%.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.5593%;\">Polaridad<\/td>\n<td style=\"width: 49.3585%;\" colspan=\"4\">Conmutaci\u00f3n positiva, negativa o autom\u00e1tica<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.5593%;\">Cambio de fase<\/td>\n<td style=\"width: 49.3585%;\" colspan=\"4\">As\u00edncrono, sincronizaci\u00f3n 0\u00b0~360\u00b0 o \u00e1ngulo espec\u00edfico<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.5593%;\">Impedancia de salida<\/td>\n<td style=\"width: 49.3585%;\" colspan=\"4\">12\u03a9, 30\u03a9<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.5593%;\">Red de Acoplamiento\/Desacoplamiento (CDN)<\/td>\n<td style=\"width: 8.98446%;\">Incluye un monof\u00e1sico de 16 A<\/td>\n<td style=\"width: 12.6513%;\">Incluye un 20A trif\u00e1sico\/5 cables<\/td>\n<td style=\"width: 14.8106%;\">Incluye un monof\u00e1sico de 16 A<\/td>\n<td style=\"width: 12.9121%;\">Incluye un 20A trif\u00e1sico\/5 cables<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.5593%;\">Poder de trabajo<\/td>\n<td style=\"width: 49.3585%;\" colspan=\"4\">AC220V (Opci\u00f3n 110V) \u00b110%, 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.5593%;\">Dimensiones (DxAxH)<\/td>\n<td style=\"width: 8.98446%;\">44x45x35cm<\/td>\n<td style=\"width: 12.6513%;\">44x45x20cm 44x45x35cm (CDN)<\/td>\n<td style=\"width: 14.8106%;\">44x45x30cm 44x45x20cm (CDN)<\/td>\n<td style=\"width: 12.9121%;\">44x45x30cm 44x45x35cm (CDN)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.5593%;\">Peso bruto<\/td>\n<td style=\"width: 8.98446%;\">Alrededor de 28 kg<\/td>\n<td style=\"width: 12.6513%;\">Unos 46 kg<\/td>\n<td style=\"width: 14.8106%;\">Unos 45 kg<\/td>\n<td style=\"width: 12.9121%;\">Unos 48 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Pantalla t\u00e1ctil LCD supergrande y Windows CE integrado<\/strong><\/p>\n<p style=\"text-align: left;\"><strong>Forma de onda:<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-3716\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/ring-wave-generator-waveform-1-750x450.jpg\" alt=\"Forma de onda del generador de ondas en anillo\" width=\"1000\" height=\"600\" title=\"\"><\/p>\n<p><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-rwg61000-12-ring-wave-generator-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\">LISUN RWG61000-12 Generador de ondas en anillo - Preguntas frecuentes postventa (FAQ)<\/a><\/span><br \/>\n<\/strong>El generador de ondas en anillo LISUN RWG61000-12 lleva en el mercado m\u00e1s de 10 a\u00f1os, el equipo de servicio de ingenieros de LISUN ya ha resumido la mayor\u00eda de las preguntas y respuestas de postventa en el enlace anterior. Por favor, l\u00e9alo atentamente, puede resolver la mayor\u00eda de los problemas por s\u00ed mismo si tiene algunas preguntas durante el uso de los instrumentos. LISUN seguir\u00e1 actualizando estas p\u00e1ginas y podr\u00e1 encontrar m\u00e1s preguntas frecuentes en este enlace.<\/p>","protected":false},"excerpt":{"rendered":"<p>Ring wave test generator is designed according to the IEC61000-4-12, EN61000-4-12, ANSI-C62-41 and GB\/T17626.12. This instrument is used for the simulative electrical network, the power supply of the reactive load and the control line switch, as well as sensing the ring wave of the low voltage cables terminal equipment caused by the disconnection of the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3570,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[215],"class_list":["post-2461","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-rwg61000-12"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts\/2461","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/comments?post=2461"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts\/2461\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/media\/3570"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/media?parent=2461"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/categories?post=2461"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/tags?post=2461"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}