{"id":2494,"date":"2025-06-19T19:36:21","date_gmt":"2025-06-19T11:36:21","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/composite-salt-spray-test-machine\/"},"modified":"2025-07-03T14:38:31","modified_gmt":"2025-07-03T06:38:31","slug":"composite-salt-spray-test-machine","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/es\/productos\/composite-salt-spray-test-machine\/","title":{"rendered":"C\u00e1mara de ensayo de niebla salina de materiales compuestos"},"content":{"rendered":"<p>YWX\/Q-150X series Composite Salt Spray Test Machine do measurement through simulating conditions that are more commonly encountered in the natural environment such as\u00a0 salt spray, hot air drying, humidity, low temperature combined and loop in any order. It is widely used to test items used in drastically changing environments, such as automobile parts, aviation equipment, building materials, coating, electric and electrical machinery so on.<\/p>\n<p><strong>Est\u00e1ndar<\/strong>:<br \/>\nGB\/T 2423.18 \u201cEnvironmental testing \u2013 Part 2: Test methods \u2013 Test Kb: Salt mist, cyclic (sodium chloride solution)\u201d<br \/>\nIEC 60068-2-52 \u201cEnrironmental testing -Part 2-52: Tests \u2013 Test Kb: Salt mist, cyclic (sodium chloride solution)\u201d<br \/>\nISO 3769 \u201cMetallic coatings \u2013 Acetic acid salt spray test (ASS test)\u201d<br \/>\nVDA233-102 \u201cCyclic corrosion testing of materials &amp; components in automotive construction\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/GMW14872-2013-Chinese-Version-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GMW 14872<\/a> \u201cCyclic Corrosion Laboratory Test\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/TCSAE-71-2018-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">TCSAE 71<\/a> \u201cCyclic corrosion test methods of automotive assemblies and materials\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/VCS_1027_1449-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">VCS 1027 1449<\/a> \u201cAccelerated Cyclic Corrosion Test\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/PV-1210-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">PV 1210<\/a> \u201cCorrosion Test\u201d<\/p>\n<p><strong>Specififation:<\/strong><\/p>\n<table style=\"width: 97.1582%; height: 1274px;\" width=\"636\">\n<tbody>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Modelo LISUN<\/td>\n<td style=\"width: 16.0397%; text-align: center; vertical-align: middle;\" width=\"101\">YWX\/Q-250X<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"97\">YWX\/Q-750X<\/td>\n<td style=\"width: 16.4822%; text-align: center; vertical-align: middle;\" width=\"96\">YWX\/Q-010X<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"94\">YWX\/Q-016X<\/td>\n<td style=\"width: 15.3761%; text-align: center; vertical-align: middle;\" width=\"123\">YWX\/Q-020X<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Tama\u00f1o de la sala de trabajo<\/td>\n<td style=\"width: 16.0397%; text-align: center; vertical-align: middle;\" width=\"101\">900*600*500<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"97\">1100*750*500<\/td>\n<td style=\"width: 16.4822%; text-align: center; vertical-align: middle;\" width=\"96\">1200*800*500<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"94\">1600*1000*600<\/td>\n<td style=\"width: 15.3761%; text-align: center; vertical-align: middle;\" width=\"123\">2000*1000*600<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Dimensiones exteriores<\/td>\n<td style=\"width: 16.0397%; text-align: center; vertical-align: middle;\" width=\"101\">2160*1100*1300<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"97\">2360*1250*1300<\/td>\n<td style=\"width: 16.4822%; text-align: center; vertical-align: middle;\" width=\"96\">2460*1300*1350<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"94\">2860*1500*1450<\/td>\n<td style=\"width: 15.3761%; text-align: center; vertical-align: middle;\" width=\"123\">3260*1500*1450<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Capacidad<\/td>\n<td style=\"width: 16.0397%; text-align: center; vertical-align: middle;\" width=\"101\">270L<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"97\">412L<\/td>\n<td style=\"width: 16.4822%; text-align: center; vertical-align: middle;\" width=\"96\">480L<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"94\">960L<\/td>\n<td style=\"width: 15.3761%; text-align: center; vertical-align: middle;\" width=\"123\">1200L<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Volumen del dep\u00f3sito de soluci\u00f3n<\/td>\n<td style=\"width: 16.0397%; text-align: center; vertical-align: middle;\" width=\"101\">25L<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"97\">30L<\/td>\n<td style=\"width: 16.4822%; text-align: center; vertical-align: middle;\" width=\"96\">30L<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"94\">35L<\/td>\n<td style=\"width: 15.3761%; text-align: center; vertical-align: middle;\" width=\"123\">40L<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Pure water tank volume<\/td>\n<td style=\"width: 16.0397%; text-align: center; vertical-align: middle;\" width=\"101\">30L<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"97\">35L<\/td>\n<td style=\"width: 16.4822%; text-align: center; vertical-align: middle;\" width=\"96\">35L<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"94\">40L<\/td>\n<td style=\"width: 15.3761%; text-align: center; vertical-align: middle;\" width=\"123\">50L<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" rowspan=\"2\" width=\"125\">Potencia de trabajo<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">Three Phase AC 380V\/50HZ (60Hz is optional)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 16.0397%; text-align: center; vertical-align: middle;\" width=\"101\">10.0KW<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"97\">12.0KW<\/td>\n<td style=\"width: 16.4822%; text-align: center; vertical-align: middle;\" width=\"96\">12.5KW<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"94\">16.0KW<\/td>\n<td style=\"width: 15.3761%; text-align: center; vertical-align: middle;\" width=\"123\">18.5KW<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Espacio disponible para muestras<\/td>\n<td style=\"width: 16.0397%; text-align: center; vertical-align: middle;\" width=\"101\">700*450*250<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"97\">900*600*300<\/td>\n<td style=\"width: 16.4822%; text-align: center; vertical-align: middle;\" width=\"96\">1000*600*300<\/td>\n<td style=\"width: 14.4912%; text-align: center; vertical-align: middle;\" width=\"94\">1400*800*350<\/td>\n<td style=\"width: 15.3761%; text-align: center; vertical-align: middle;\" width=\"123\">1800*800*350<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">M\u00e9todo de apertura<\/td>\n<td style=\"width: 16.0397%; text-align: center; vertical-align: middle;\" width=\"101\">Manually control<\/td>\n<td style=\"width: 30.9734%; text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"193\">Soporte de muelle neum\u00e1tico de acero inoxidable<\/td>\n<td style=\"width: 29.8673%; text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"217\">Soporte de cilindro<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Working environmental temperature requirements<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">The ambient temperature is 5\u2103~30\u2103. Ventilation is recommended. When the temperature exceeds 30\u2103, it is recommended to adjust the room temperature through appropriate methods.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Working environment humidity requirements<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">Environmental humidity below 85%Rh<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">The temperature range of the salt spray chamber<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">15\u2103~65\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">El intervalo de temperatura del barril saturado<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">RT (room temperature) ~ 70 \u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Relative humidity of the salt spray chamber<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">30%-98%RH (\u00b1 3%, adjustable, refer to the temperature and humidity corresponding chart)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Rendimiento t\u00e9rmico<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">Temperature uniformity: \u22642 \u2103 Temperature volatility: \u2264 \u00b1 1 \u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Tasa de deposici\u00f3n de niebla salina<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">1-2ml\/80cm\u00b2\/h<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Test methods<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">Programmable spray, moist heat, dry, standard climate<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" rowspan=\"3\" width=\"125\">Test conditions<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">A. Saline spray test: NSS * test: 35 \u2103 \u00b1 2 \u2103 * Saturated air barrel: 47 \u2103 \u00b1 2 \u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">B. humidity and heat test: 1. Test temperature range: 20 \u2103 -60 \u2103. 2. Test humidity range: 60%RH ~ 98%RH can be adjusted.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">C. Dry test: 1. Test temperature range: 20 \u2103 ~ 60 \u2103. 2. Test humidity range: 30%RH ~ 60%RH can be adjusted.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 21.9027%; text-align: center; vertical-align: middle;\" width=\"125\">Accesorios est\u00e1ndar<\/td>\n<td style=\"width: 76.8804%; text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"511\">1 set of V -type\/O -type storage racks, 1 glass nozzle, 2 bottles of sodium sodium (500g\/bottle), 1 plastic rust barrel (5L )<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Sugerencias opcionales<\/strong>: When using LISUN YWX\/Q-010X Composite Salt Spray Test Machine, it is necessary to choose a LISUN LS-EU800W2-55L air compressor (power 800W*2, capacity 55L, speed 1380r\/min, pressure 0.7Mpa, flow 120L\/m in, 220~240V\/50Hz) or LS-US800W2-55L air compressor (power 800W*2, capacity 55L, speed 1380r\/min, pressure 0.7Mpa, flow 120L\/min, 110~120V\/60Hz).<\/p>\n<div id=\"attachment_16909\" class=\"wp-caption aligncenter\" style=\"width: 410px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-16909\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor-400x400.jpg\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor-400x400.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor-100x100.jpg 100w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LS-EU800W2-55L-Air-Compressor.jpg 500w\" alt=\"\" width=\"400\" height=\"400\" aria-describedby=\"caption-attachment-16909\" title=\"\"><\/p>\n<p id=\"caption-attachment-16909\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Compresor de aire LS-EU800W2-55L<\/span><\/p>\n<\/div>\n<p><strong>Test Principle:<\/strong><br \/>\nComposite <a href=\"https:\/\/www.lisungroup.com\/products\/environmental-test-chamber\/salt-spray-test-machine.html\" target=\"_blank\" rel=\"noopener\">Salt Spray Test Machine<\/a> is composed of the cyclic corrosion test of the spray process, the damp and heat process, and the standing and drying process. The following are the schematic diagrams of these three processes:<\/p>\n<p><strong>1. Spray process<\/strong><br \/>\nThe system consists of salt water tank, pneumatic system, salt water storage tank, spray tower, nozzle, etc. The salt solution flows from the outside to the test chamber by using the natural drop, and the salt solution is atomized by compressed air through the spray nozzle.<\/p>\n<div id=\"attachment_5816\" class=\"wp-caption aligncenter\" style=\"width: 658px;\">\n<p><img decoding=\"async\" class=\"wp-image-5816 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-2.jpg\" sizes=\"(max-width: 648px) 100vw, 648px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-2.jpg 648w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/2-2-400x254.jpg 400w\" alt=\"\" width=\"648\" height=\"411\" aria-describedby=\"caption-attachment-5816\" title=\"\"><\/p>\n<p id=\"caption-attachment-5816\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Figure 1 Schematic diagram of the spray process<\/span><\/p>\n<\/div>\n<p><strong>2. Damp heat test<\/strong><br \/>\nThe damp heat test system is composed of steam generator, blast, water circuit, condensation device, etc. After the salt spray test, the machine will set up a defogging program to discharge the salt spray out of the test room as soon as possible; Then the water evaporator will output the appropriate temperature and humidity according to the temperature and humidity set by the controller. Generally speaking, the humidity will be more accurately calibrated and constant after the temperature is stable. The temperature and humidity parameters of the damp heat test are as follows: Temperature: 30\u2103\u201460\u2103; humidity: 80%RH\u201498%RH.<\/p>\n<div id=\"attachment_5817\" class=\"wp-caption aligncenter\" style=\"width: 655px;\">\n<p><img decoding=\"async\" class=\"wp-image-5817 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-5.jpg\" sizes=\"(max-width: 645px) 100vw, 645px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-5.jpg 645w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/1-5-400x223.jpg 400w\" alt=\"\" width=\"645\" height=\"360\" aria-describedby=\"caption-attachment-5817\" title=\"\"><\/p>\n<p id=\"caption-attachment-5817\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Figure 2 Schematic diagram of damp heat test<\/span><\/p>\n<\/div>\n<p><strong>3. Drying process<\/strong><br \/>\nStanding and drying system adds drying blower, heating wire, air filter and other devices on the basis of damp heat system, if need to simulate standard atmospheric pressure environment test (temperature 23\u2103\u00b12\u2103, humidity 45%~55% RH). Firstly, quickly remove the damp and heat test environment in the previous section by setting a defogging program to create a relatively clean test environment, and then the humidifier or dehumidification system works in coordination under the controller to produce an environment that meets the test requirements. The temperature and humidity parameters of the drying test are as follows: temperature: 20\u2103-60\u2103; humidity: 30%~60%RH (corresponding to the appropriate temperature point).<\/p>\n<p>&nbsp;<\/p>\n<div id=\"attachment_5818\" class=\"wp-caption aligncenter\" style=\"width: 630px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5818 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-3.jpg\" sizes=\"(max-width: 620px) 100vw, 620px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-3.jpg 620w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/3-3-400x242.jpg 400w\" alt=\"\" width=\"620\" height=\"375\" aria-describedby=\"caption-attachment-5818\" title=\"\"><\/p>\n<p id=\"caption-attachment-5818\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Figure 3 Principle diagram of drying process<\/span><\/p>\n<\/div>\n<p>Appendix: Temperature And Humidity Corresponding Chart:<\/p>\n<div id=\"attachment_13388\" class=\"wp-caption aligncenter\" style=\"width: 1017px;\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-13388 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Temperature-and-Humidity-Corresponding-Chart.jpg\" sizes=\"(max-width: 1007px) 100vw, 1007px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Temperature-and-Humidity-Corresponding-Chart.jpg 1007w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Temperature-and-Humidity-Corresponding-Chart-400x216.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/Temperature-and-Humidity-Corresponding-Chart-768x415.jpg 768w\" alt=\"Temperature And Humidity Corresponding Chart\" width=\"1007\" height=\"544\" aria-describedby=\"caption-attachment-13388\" title=\"\"><\/p>\n<p id=\"caption-attachment-13388\" class=\"wp-caption-text\">Temperature And Humidity Corresponding Chart<\/p>\n<\/div>\n<div class=\"mceTemp\"><\/div>","protected":false},"excerpt":{"rendered":"<p>YWX\/Q-150X series Composite Salt Spray Test Machine do measurement through simulating conditions that are more commonly encountered in the natural environment such as\u00a0 salt spray, hot air drying, humidity, low temperature combined and loop in any order. It is widely used to test items used in drastically changing environments, such as automobile parts, aviation equipment, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3775,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[247],"class_list":["post-2494","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ywx-q-010x"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts\/2494","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/comments?post=2494"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts\/2494\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/media\/3775"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/media?parent=2494"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/categories?post=2494"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/tags?post=2494"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}