{"id":2608,"date":"2025-06-19T19:37:37","date_gmt":"2025-06-19T11:37:37","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/test-probe-d-with-cable-of-iec-61032-figure-4\/"},"modified":"2025-06-25T17:08:38","modified_gmt":"2025-06-25T09:08:38","slug":"test-probe-d-with-cable-of-iec-61032-figure-4","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/es\/productos\/test-probe-d-with-cable-of-iec-61032-figure-4\/","title":{"rendered":"Test Probe D with Cable of IEC 61032 Figure 4"},"content":{"rendered":"<p>IEC61032:1997 Test Probe D IP4X Test Rod 1.0 mm<\/p>\n<p><strong>Introducci\u00f3n b\u00e1sica:<\/strong><br \/>\n1. According to: GB\/T4208-2008 \/ IEC61032:1997 \/ IEC60529:2001 \/ IEC60065 \/ IEC60598 and UL<br \/>\n2. IP4X Test Probe D ( Test Probe D) is the necessary tool to proceed protecting electric shock test of household and similar electrical appliances.<\/p>\n<p><strong>Par\u00e1metros t\u00e9cnicos:<\/strong><br \/>\n1. Test rod length: 100 mm<br \/>\n2. Test rod diameter: 1.0 mm<br \/>\n3. Di\u00e1metro del deflector circular: 35 mm<br \/>\n4. Di\u00e1metro del mango: 10 mm<br \/>\n5. Longitud del mango: 100 mm<br \/>\n6. According to IEC61032 figure 4 (the Test probe D).<\/p>\n<p><strong>Aplicaci\u00f3n:<\/strong><br \/>\n1. Prueba est\u00e1ndar se refiere a la parte conjunta no puede tocar las partes vivas o cerca de las partes peligrosas. y 35mm deflector circular no se puede introducir.<br \/>\n2. In the test requirement for preventing access to the hazardous parts. Test Probe D need to be with push force 1\u00b10.1N.<\/p>\n<p><strong>Prop\u00f3sito:<\/strong><br \/>\nEsta sonda sirve para verificar la protecci\u00f3n b\u00e1sica contra el acceso a piezas peligrosas. Tambi\u00e9n sirve para verificar la protecci\u00f3n contra el acceso con una herramienta.<\/p>\n<p><strong>Nota:<\/strong><br \/>\nPara los productos sin empuje, utilice un medidor de fuerza de empuje y tracci\u00f3n.<\/p>\n<p><strong>Est\u00e1ndar:<\/strong><br \/>\nIEC 61032 \"Protecci\u00f3n de personas y equipos mediante envolventes - Sondas para verificaci\u00f3n\"<br \/>\nIEC 60529 \"Grados de protecci\u00f3n proporcionados por las envolventes (C\u00f3digo IP)\"<br \/>\nIEC 60065 \"Aparatos de audio, v\u00eddeo y aparatos electr\u00f3nicos an\u00e1logos - Requisitos de seguridad\"<br \/>\nIEC 60598-1 \"Luminarias - Parte 1. Requisitos generales: Requisitos generales y ensayos\"<br \/>\nUL, GB\/T 4208<\/p>\n<div id=\"attachment_12290\" class=\"wp-caption aligncenter\" style=\"width: 708px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-12290 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/09\/SMT-1204C_YK.png\" sizes=\"(max-width: 698px) 100vw, 698px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/09\/SMT-1204C_YK.png 698w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/09\/SMT-1204C_YK-400x113.png 400w\" alt=\"\" width=\"698\" height=\"198\" aria-describedby=\"caption-attachment-12290\" title=\"\"><\/p>\n<p id=\"caption-attachment-12290\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Test Probe D with Cable of IEC61032 Figure 4<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>IEC61032:1997 Test Probe D IP4X Test Rod 1.0 mm Basic Introduction: 1. According to: GB\/T4208-2008 \/ IEC61032:1997 \/ IEC60529:2001 \/ IEC60065 \/ IEC60598 and UL 2. IP4X Test Probe D ( Test Probe D) is the necessary tool to proceed protecting electric shock test of household and similar electrical appliances. Technical parameter: 1. Test rod [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3614,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[352],"class_list":["post-2608","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-smt-1204c"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts\/2608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/comments?post=2608"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/posts\/2608\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/media\/3614"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/media?parent=2608"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/categories?post=2608"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/es\/wp-json\/wp\/v2\/tags?post=2608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}