{"id":2335,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/high-frequency-power-supply\/"},"modified":"2025-06-27T10:26:53","modified_gmt":"2025-06-27T02:26:53","slug":"high-frequency-power-supply","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/fr\/produits\/high-frequency-power-supply\/","title":{"rendered":"Alimentation \u00e0 haute fr\u00e9quence"},"content":{"rendered":"<p>The HFP-800 High Frequency Power Supply works with LPS-3 (<a href=\"https:\/\/www.lisungroup.com\/products\/cfl-testing-instruments\/lamp-preheat-assistant-source.html\" target=\"_blank\" rel=\"noopener\">Pr\u00e9chauffage de la lampe Assistant Source<\/a>) and RB-3 (<a href=\"https:\/\/www.lisungroup.com\/products\/cfl-testing-instruments\/adjustable-resistance-ballast.html\" target=\"_blank\" rel=\"noopener\">Ballast de r\u00e9sistance r\u00e9glable<\/a>) to be an IEC Standard Test System which used to test the high frequency fluorescent Lamp such as T5 Tube. Please visit this page to view <a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/how-to-measure-the-high-frequency-fluorescent-lamp.html\" target=\"_blank\" rel=\"noopener\">How to Measure the High Frequency Fluorescent Lamp<\/a>.<\/p>\n<p><strong>Standard :<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-ANSLG-C78.81-2013-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-ANSLG-C78.81<\/a> \u201cAmerican National Standard for electric lamps \u2013 Specifications for the Chormaticity of Solid State Lighting Products\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-ANSLG-C82.11-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-ANSLG-C82.11<\/a> \u201cLamp Preheat Assistant Source Auxiliary Power Supply\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC62776-2014-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC62776<\/a> \u201cDouble \u2013 capped LED Lamps designed to retrofit linear fluorescent lamps \u2013 Safety specifications\u201d<br \/>\nIEC 60929:2015\/<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-15144-2005-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T-15144<\/a> \u201cAC and\/ or DC-supplied electronic control gear for tubular fluorescent lamps \u2013 Performance requirements\u201d<br \/>\nIEC 60901 (<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-17262-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T17262<\/a>) \u201cSingle-Capped Fluorescent Lamps \u2013 Performance Requirements\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60081-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60081<\/a> (<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-10682-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T10682<\/a>) \u201cDouble-capped fluorescent lamps \u2013 Performance specification\u201d<\/p>\n<p><strong>Feature:<\/strong><br \/>\n\u2022 Program control output voltage and easy operation<br \/>\n\u2022 Set data easily with a memory chip, unnecessary to set for many times<br \/>\n\u2022 Display on four windows, each window shows one parameter independently<br \/>\n\u2022 Application for all kinds fluorescent lamps such as 50Hz\/60Hz T8\/T12 tube or 25KHz T5 Tube<br \/>\n\u2022 It is according to double-ended fluorescent lamps adoptting the <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60081-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60081<\/a> (<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-10682-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T10682<\/a>) and the single-ended fluorescent lamps adoptting the IEC 60901 (<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-17262-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T17262<\/a>)<\/p>\n<p><strong>Sp\u00e9cification:<\/strong><br \/>\n\u2022 Range for output voltage: 10~600V (Adjustable)<br \/>\n\u2022 Range for output current: 0~0.600A<br \/>\n\u2022 Range for output frequency: 25KHz<br \/>\n\u2022 Range for output capacity: 0~300W (Special request to 500W)<br \/>\n\u2022 Range for Voltage stability: 0.5%\/30 minutes<br \/>\n\u2022 Range for frequency stability: 0.02%<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-4409 size-large\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HFP-800RB-3LPS-3_AL-1080x1080.jpg\" sizes=\"(max-width: 1080px) 100vw, 1080px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HFP-800RB-3LPS-3_AL-1080x1080.jpg 1080w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HFP-800RB-3LPS-3_AL-100x100.jpg 100w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HFP-800RB-3LPS-3_AL-400x400.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HFP-800RB-3LPS-3_AL-768x768.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HFP-800RB-3LPS-3_AL.jpg 1200w\" alt=\"\" width=\"1080\" height=\"1080\" title=\"\"><\/p>\n<p><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-hfp-800-high-frequency-power-supply-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\">LISUN HFP-800 High Frequency Power Supply \u2013 After-sales Frequently Asked Questions (FAQ)<\/a><\/span><br \/>\n<\/strong>LISUN HFP-800 High Frequency Power Supply were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>The HFP-800 High Frequency Power Supply works with LPS-3 (Lamp Preheat Assistant Source) and RB-3 (Adjustable Resistance Ballast) to be an IEC Standard Test System which used to test the high frequency fluorescent Lamp such as T5 Tube. Please visit this page to view How to Measure the High Frequency Fluorescent Lamp. Standard: ANSI-ANSLG-C78.81 \u201cAmerican [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3352,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[93],"class_list":["post-2335","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-hfp-800"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts\/2335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/comments?post=2335"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts\/2335\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/media\/3352"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/media?parent=2335"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/categories?post=2335"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/tags?post=2335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}