{"id":2377,"date":"2025-06-19T19:35:13","date_gmt":"2025-06-19T11:35:13","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60669-1-clause-19-1-and-19-2-externally-ballasted-fluorescent-lamp-test-load-cabinet\/"},"modified":"2025-07-01T16:42:26","modified_gmt":"2025-07-01T08:42:26","slug":"iec-60669-1-clause-19-1-and-19-2-externally-ballasted-fluorescent-lamp-test-load-cabinet","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/fr\/produits\/iec-60669-1-clause-19-1-and-19-2-externally-ballasted-fluorescent-lamp-test-load-cabinet\/","title":{"rendered":"Chargement de l'armoire UL1054"},"content":{"rendered":"<p>The DFX-20 Externally Ballasted Lamp Test Load Cabinet (Resistive, Inductive, and Capacitive Load cabinet) is designed and manufactured according to standards such as IEC 60669-1 Clause 19.1 and 19.2 (GB 16915.1 Clause 19.1 and 19.2), IEC 60884-1 Clause 20\/21 (GB\/T 2099.1 Clause 20\/21) and IEC 60898-1 Clause 9.11 (GB\/T 10963.1 Clause 9.11).<\/p>\n<p><strong>Standard :<\/strong><br \/>\nIEC 60669-1 (GB 16915.1) \u201cSwitches for household and similar fixed-electrical installations \u2013 Part 1: General requirements\u201d Clause 19.1 and 19.2<br \/>\nIEC 60884-1 (GB\/T 2099.1) \u201cPlugs and socket-outlets for household and similar purposes \u2013 Part 1: General requirements\u201d Clause 20\/21<br \/>\nIEC 60898-1 (GB\/T 10963.1) \u201cElectrical accessories \u2013 Circuit-breakers for overcurrent protection for household and similar installations \u2013 Part 1: Circuit-breakers for a.c. operation\u201d Clause 9.11<\/p>\n<p><strong>Sp\u00e9cification:<\/strong><br \/>\n\u2022 Output modes: Resistive, Inductive and Capacitive<br \/>\n\u2022 Voltage output range: 0~275V; Accuracy: 1V<br \/>\n\u2022 Power Factor PF: Adjustable from 0.30 to 0.98 when current is below 16A; Adjustable from 0.60 to 0.98 when current is above 16A; Resolution of Power factor resolution is 0.01<br \/>\n\u2022 Built-in digital power meter; It can measuring AC voltage, current, power, and power factor; Accuracy: \u00b1 (0.4% of reading + 0.1% of range + 1 digit)<br \/>\n\u2022 Load A: Capacitors are equipped with two sets, one set is 70uF and the other set is 140uF; Load B: Capacitance is 7.3uF, inductance is 0.5H.<br \/>\n\u2022 Counter: 0\uff5e999,999 times<\/p>\n<table style=\"width: 100.399%; height: 364px;\" width=\"682\">\n<tbody>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"97\"><strong>Mod\u00e8le LISUN<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"117\"><strong>DFX-20<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"117\"><strong>DFX-20-3CH<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"117\"><strong>DFX-40<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"117\"><strong>DFX-60<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"117\"><strong>DFX-80<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"97\">Current output range<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"2\" width=\"234\">0~20A\/Each channel<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"117\">0~40A<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"117\">0~60A<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"117\">0~80A<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"97\">Current output accuracy<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"468\">0.1A<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"97\">Output Channel<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"117\">Single output<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"117\">3 Channels output<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"351\">Single output<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"97\">Input Voltage \/ Frequency<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"5\" width=\"585\">AC 220~240V, 50Hz\/60Hz<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\">Input Current<\/td>\n<td style=\"text-align: center; vertical-align: middle;\">40A<\/td>\n<td style=\"text-align: center; vertical-align: middle;\">100A<\/td>\n<td style=\"text-align: center; vertical-align: middle;\">80A<\/td>\n<td style=\"text-align: center; vertical-align: middle;\">120A<\/td>\n<td style=\"text-align: center; vertical-align: middle;\">160A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Application<\/strong>\uff1aDFX-20 can work together with CZKS-3 3 position\/CZKS-6 <a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/6-position-plug-socket-switch-life-tester.html\" target=\"_blank\" rel=\"noopener\">6 Position Plug Socket Switch Life Tester<\/a>\uff0cand it also can work with SW-6 <a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/power-cord-bending-tester.html\" target=\"_blank\" rel=\"noopener\">Power Cord Bending Tester<\/a>.<\/p>\n<div id=\"attachment_14356\" class=\"wp-caption aligncenter\" style=\"width: 860px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14356\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720240401150744.jpg\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720240401150744.jpg 630w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720240401150744-378x400.jpg 378w\" alt=\"IEC60669-1 Test for switches intended for inductive loads\" width=\"850\" height=\"899\" aria-describedby=\"caption-attachment-14356\" title=\"\"><\/p>\n<p id=\"caption-attachment-14356\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC60669-1 Test for switches intended for inductive loads<\/span><\/p>\n<\/div>\n<div id=\"attachment_14232\" class=\"wp-caption aligncenter\" style=\"width: 860px;\">\n<p><img decoding=\"async\" class=\"wp-image-14232\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-2.jpg\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-2.jpg 953w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-2-400x273.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/4-2-768x525.jpg 768w\" alt=\"\" width=\"850\" height=\"581\" aria-describedby=\"caption-attachment-14232\" title=\"\"><\/p>\n<p id=\"caption-attachment-14232\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC60669-1 19.2 Test for switches intended for externally ballasted lamp loads<\/span><\/p>\n<\/div>\n<div id=\"attachment_14233\" class=\"wp-caption aligncenter\" style=\"width: 860px;\">\n<p><img decoding=\"async\" class=\"wp-image-14233\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-1.jpg\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-1.jpg 1004w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-1-400x188.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/5-1-768x361.jpg 768w\" alt=\"IEC 60669-1 Figure 12a - Circult diagrams for testing switches for use on externally ballasted lamp loads\" width=\"850\" height=\"400\" aria-describedby=\"caption-attachment-14233\" title=\"\"><\/p>\n<p id=\"caption-attachment-14233\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60669-1 Figure 12a \u2013 Circult diagrams for testing switches for use on externally ballasted lamp loads<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The DFX-20 Externally Ballasted Lamp Test Load Cabinet (Resistive, Inductive, and Capacitive Load cabinet) is designed and manufactured according to standards such as IEC 60669-1 Clause 19.1 and 19.2 (GB 16915.1 Clause 19.1 and 19.2), IEC 60884-1 Clause 20\/21 (GB\/T 2099.1 Clause 20\/21) and IEC 60898-1 Clause 9.11 (GB\/T 10963.1 Clause 9.11). Standard: IEC 60669-1 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3105,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[134],"class_list":["post-2377","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-dfx-20"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts\/2377","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/comments?post=2377"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts\/2377\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/media\/3105"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/media?parent=2377"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/categories?post=2377"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/tags?post=2377"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}