{"id":2507,"date":"2025-06-19T19:36:32","date_gmt":"2025-06-19T11:36:32","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/face-masks-particulate-filtration-efficiency-pfe-tester\/"},"modified":"2025-06-28T20:49:30","modified_gmt":"2025-06-28T12:49:30","slug":"face-masks-particulate-filtration-efficiency-pfe-tester","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/fr\/produits\/face-masks-particulate-filtration-efficiency-pfe-tester\/","title":{"rendered":"Face Masks Particulate Filtration Efficiency PFE Tester"},"content":{"rendered":"<p>GLE-20 is an oil-salt two-in-one Face Masks Particulate Filtration Efficiency PFE Tester. It is designed ccording to<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/ASTM-F1862-17-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\"> ASTM F1862-17<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/ASTM-F2299-032017-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ASTM F2299-03 (2017)<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/ASTM-F2100-2019-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ASTM F2100-2019<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN14683-2019-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN14683-2019<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN-14387-2004A1-2008-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN 14387-2004+A1 2008<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN-136-1998-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN 136-1998<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN-140-1999-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN 140-1999<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN-143-2000C1-A1-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN 143-2000 +C1-A1<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN-149-2001A1-2009-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN 149-2001+A1<\/a>, etc. It is used to test the particulate filtering efficiency of daily protective masks and medical masks, and to determine the obstruction performance of ordinary fabrics and medical protective masks against a constant flow of airflow. It is widely used for medical device inspection centers, safety protection inspection centers, labor protection inspection centers, drug inspection centers, disease prevention and control centers, textile testing centers, hospitals, mask manufacturers, etc.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-5410 size-full aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/04\/MASK-1_AL11-e1591865531262.jpg\" sizes=\"(max-width: 500px) 100vw, 500px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/04\/MASK-1_AL11-e1591865531262.jpg 500w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/04\/MASK-1_AL11-e1591865531262-400x242.jpg 400w\" alt=\"\" width=\"500\" height=\"302\" title=\"\"><\/p>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/ASTM-F1862-17-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ASTM F1862 \u201cStandard Test Method for Resistance of Medical Face Masks to Penetration by Synthetic Blood (Horizontal Projection of Fixed Volume at a Known Velocity)\u201d<\/a><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/ASTM-F2299-032017-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ASTM F2299 \u201cStandard Test Method for Determining the Initial Efficiency of Materials Used in Medical Face Masks to Penetration by Particulates Using Latex Spheres\u201d<\/a><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/ASTM-F2100-2019-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ASTM F2100 \u201cStandard Specification for Performance of Materials Used in Medical Face Masks\u201d<\/a><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN14683-2019-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN14683 \u201cMedical face masks. Requirements and test methods\u201d<\/a><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN-14387-2004A1-2008-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN 14387 \u201cRespiratory protective devices. Gas filter(s) and combined filter(s). Requirements, testing, marking\u201d<\/a><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN-136-1998-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN 136 \u201cRespiratory protective devices. Full face masks. Requirements, testing, marking\u201d<\/a><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN-140-1999-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN 140 \u201cRespiratory protective devices. Half masks and quarter masks. Requirements, testing, marking\u201d<\/a><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN-143-2000C1-A1-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN 143 \u201cRespiratory protective devices. Particle filters. Requirements, testing, marking\u201d<\/a><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/BS-EN-149-2001A1-2009-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">BS EN 149 \u201cRespiratory protective devices. Filtering half masks to protect against particles. Requirements, testing, marking\u201d<\/a><br \/>\nEN 1822-3 \u201cHigh efficiency air filters (EPA, HEPA and ULPA) \u2013 Part 3: Testing flat sheet filter media\u201d<br \/>\nGB 2626 \u201cRespiratory Protective Equipment Self-Suction Filter Anti-Particle Respirator\u201d<br \/>\nGB \/ T 32610 \u201cTechnical Specifications for Daily Protective Masks\u201d<br \/>\nGB \/ T 19082 \u201cTechnical requirements for medical disposable protective clothing\u201d<br \/>\nGB \/ T 19083 \u201cTechnical Requirements for Medical Protective Masks\u201d<br \/>\nGB 24539 General technical requirements for protective clothing and chemical protective clothing<br \/>\nYY 0469 \u201cTechnical Requirements for Medical Surgical Masks\u201d<br \/>\nYY \/ T 0969 \u201cStandard for disposable medical masks\u201d<\/p>\n<p><strong>Standard Requirement:<br \/>\n<\/strong>Using sodium chloride particles to detect KN filter elements, and use dioctyl phthalate or equivalent oil particles (or paraffin oil) to detect KP filter elements.<br \/>\nTest according to 6.3<br \/>\nDuring the test, the filtration efficiency of each sample should always meet the requirements of Table 2<\/p>\n<p style=\"text-align: center;\"><strong>Filtration efficiency<\/strong><\/p>\n<table style=\"width: 97.5283%;\">\n<tbody>\n<tr>\n<td style=\"width: 32.5585%;\" width=\"189\">Filter element category and level<\/td>\n<td style=\"width: 38.3066%;\" width=\"189\">Particle detection with sodium chloride<\/td>\n<td style=\"width: 50.1798%;\" width=\"189\">Detection with oil particles<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.5585%;\" width=\"189\">KN90<\/td>\n<td style=\"width: 38.3066%;\" width=\"189\">90.0%<\/td>\n<td style=\"width: 50.1798%;\" rowspan=\"3\" width=\"189\">&nbsp;<\/p>\n<p>Not Siut<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.5585%;\" width=\"189\">KN95<\/td>\n<td style=\"width: 38.3066%;\" width=\"189\">95.0%<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.5585%;\" width=\"189\">KN100<\/td>\n<td style=\"width: 38.3066%;\" width=\"189\">99.97%<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.5585%;\" width=\"189\">KP90<\/td>\n<td style=\"width: 38.3066%;\" rowspan=\"3\" width=\"189\">&nbsp;<\/p>\n<p>Not Suit<\/td>\n<td style=\"width: 50.1798%;\" width=\"189\">90.0%<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.5585%;\" width=\"189\">KP95<\/td>\n<td style=\"width: 50.1798%;\" width=\"189\">95.0%<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 32.5585%;\" width=\"189\">KP100<\/td>\n<td style=\"width: 50.1798%;\" width=\"189\">99.97%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>Sp\u00e9cification:<\/b><\/p>\n<ol>\n<li>Filtration efficiency detection flowmeter range: (10 \uff5e 100) L \/ min, accuracy level 2.5<\/li>\n<li>Filtration efficiency detection range: (0.001 \uff5e999)%.<\/li>\n<li>Filtering efficiency sampling frequency: 1-9999 times \/ min can be set arbitrarily.<\/li>\n<li>Filtration efficiency Particulate concentration: (0.001-200) mg \/ m\u00b3.<\/li>\n<li>Differential pressure sensor range: 0 \uff5e1000pa<\/li>\n<li>Counting median diameter: salt particles (0.075 \u00b10.02) \u03bcm, oil particles (0.185 \u00b1 0.02) \u03bcm. Geometric standard deviation of particle size distribution: salt particles\u22641.86, oil particles\u22641.60. Dynamic detection range: 0.001-100 mg \/ m\u00b3, accuracy 1%.<\/li>\n<li>Test area: 100cm\u00b2.<\/li>\n<li>Aerosol: NaCl (optionally with DOP, DEHS, paraffin oil, corn oil).<\/li>\n<li>Aerosol concentration: 12-20mg \/ m\u00b3 (Nacl), 50-200mg \/ m\u00b3 (DOP).<\/li>\n<li>The system contains two independent aerosol generators: oily and salty aerosol generators containing two particle counting sensors, one particle concentration sensor and one particle generator<\/li>\n<li>Power: AC220V 50Hz(120V\/60Hz can be customized)<\/li>\n<\/ol>\n<p><strong>GLE-20 Characteristic:<\/strong><\/p>\n<ol>\n<li>The oil and salt two-in-one test and the two sets of test hardware systems are completely independent. The test does not interfere with each other to ensure the accuracy of the oil and salt test.<\/li>\n<li>The aerosol generator is used to produce continuous and stable aerosol particles, which is convenient for filling the solution.<\/li>\n<li>A high-precision particle concentration counter (the core component of the sensor imported from the United States) is used to measure the number of aerosol particles.<\/li>\n<li>The whole particle anti-leakage design protects the safety of laboratory personnel.<\/li>\n<li>Equipped with aerosol particulate static neutralization device.<\/li>\n<li>Configure temperature and humidity sensor, real-time display of ambient temperature and humidity (temperature and humidity requirements: 25 \u2103 \u00b1 5 \u2103, 30% RH \u00b1 10% RH).<\/li>\n<li>Equipped with glass rotor flowmeter, vacuum pump and gas electromagnetic flowmeter.<\/li>\n<li>Control system: touch-screen computer and test software have been configured to automatically test gas concentration and filtration efficiency, save, output, query, copy and export test data, support A4 paper printing and small bill printing test results<\/li>\n<\/ol>\n<p><strong>Test Report (PDF Report and Result Receipt, can also print in English):<br \/>\n<img decoding=\"async\" class=\"alignnone wp-image-5513\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/test-report-764x1080.jpg\" alt=\"\" width=\"509\" height=\"747\" title=\"\"> <img decoding=\"async\" class=\"alignnone wp-image-5546\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/2-2-283x400.png\" sizes=\"(max-width: 259px) 100vw, 259px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/2-2-283x400.png 283w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/05\/2-2.png 298w\" alt=\"\" width=\"259\" height=\"366\" title=\"\"><\/strong><\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-gle-20-face-masks-particulate-filtration-efficiency-pfe-tester-after-sales-questions-and-answers.html \" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN GLE-20 Face Masks Particulate Filtration Efficiency PFE Tester \u2013 After-sales Frequently Asked Questions (FAQ)<\/span><\/a><br \/>\n<\/strong>LISUN GLE-20 Face Masks Particulate Filtration Efficiency PFE Tester were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>GLE-20 is an oil-salt two-in-one Face Masks Particulate Filtration Efficiency PFE Tester. It is designed ccording to ASTM F1862-17, ASTM F2299-03 (2017), ASTM F2100-2019, BS EN14683-2019, BS EN 14387-2004+A1 2008, BS EN 136-1998, BS EN 140-1999, BS EN 143-2000 +C1-A1, BS EN 149-2001+A1, etc. It is used to test the particulate filtering efficiency of daily [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4993,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[260],"class_list":["post-2507","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-gle-20"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts\/2507","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/comments?post=2507"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts\/2507\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/media\/4993"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/media?parent=2507"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/categories?post=2507"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/tags?post=2507"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}