{"id":2842,"date":"2025-06-19T19:40:57","date_gmt":"2025-06-19T11:40:57","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-63294-iec-60245-1-iec-60227-1-static-flexibility-test-machine-for-flexible-cables\/"},"modified":"2025-06-25T13:40:55","modified_gmt":"2025-06-25T05:40:55","slug":"iec-63294-iec-60245-1-iec-60227-1-machine-dessai-de-flexibilite-statique-pour-cables-flexibles","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/fr\/produits\/iec-63294-iec-60245-1-iec-60227-1-machine-dessai-de-flexibilite-statique-pour-cables-flexibles\/","title":{"rendered":"IEC 63294 IEC 60245-1 IEC 60227-1 Machine d'essai de flexibilit\u00e9 statique pour c\u00e2bles souples"},"content":{"rendered":"<p>La machine d'essai de flexibilit\u00e9 statique WDT-3 pour c\u00e2bles souples est enti\u00e8rement conforme \u00e0 la norme IEC 60245-1:2008 Clause 5.6.3.2 (GB\/T 5013.1-2008 Clause 5.6.3.2), IEC 63294 (IEC 60245-2 Clause 3.2 Figure 2 (GB\/T 5013.2-2008 Clause 3.2 Figure 2)), IEC 60227-1:2024 Clause 5.6.3.2 (GB\/T 5023.1-2008 Clause 5.6.3.2), IEC 63294 (IEC 60227-2:2008 Clause 3.2 Figure 2 (GB\/T 5023.2-2008 Clause 3.2 Figure 2)). Il est utilis\u00e9 pour l'essai de flexibilit\u00e9 statique des c\u00e2bles souples dans le cadre de l'essai de r\u00e9sistance m\u00e9canique (Remarque : cet essai ne convient pas aux c\u00e2bles comportant plus de deux couches concentriques avec une section nominale de conducteur de plus de 18 \u00e2mes).<\/p>\n<p>Principe du test : l'\u00e9chantillon de 3 m de long est initialement fix\u00e9 \u00e0 200 mm \u00e0 l'extr\u00e9mit\u00e9 de serrage, puis une extr\u00e9mit\u00e9 est d\u00e9plac\u00e9e pour plier le c\u00e2ble flexible en forme de U standard, et la distance entre les deux extr\u00e9mit\u00e9s de serrage est mesur\u00e9e.<\/p>\n<p><strong>Standard :<br \/>\n<\/strong>IEC 63294 (IEC 60245-2, IEC 60227-2, GB\/T 5013.2, GB\/T 5023.2) \"M\u00e9thodes d'essai pour les c\u00e2bles \u00e9lectriques de tension nominale inf\u00e9rieure ou \u00e9gale \u00e0 450\/750 V\".<br \/>\nIEC 60245-1 (GB\/T 5013.1) \"C\u00e2bles \u00e0 isolation caoutchouc - Tensions assign\u00e9es au plus \u00e9gales \u00e0 450\/750 V - Partie 1 : Exigences g\u00e9n\u00e9rales\" Clause 5.6.3.2<br \/>\nIEC 60227-1 (GB\/T 5023.1) \"C\u00e2bles isol\u00e9s au polychlorure de vinyle de tension assign\u00e9e au plus \u00e9gale \u00e0 450\/750 V - Partie 1 : Exigences g\u00e9n\u00e9rales\" Clause 5.6.3.2<\/p>\n<p><strong>Sp\u00e9cification:<\/strong><br \/>\n- Longueur de flexion : 200 -1500(mm)<br \/>\n- Diam\u00e8tre ext\u00e9rieur de l'\u00e9chantillon : \u03c66 - 32(mm)<br \/>\n- Longueur de l'\u00e9chantillon : 3000\u00b15% (mm)<br \/>\n- Hauteur au-dessus du sol : 1500mm<br \/>\n- Dimensions totales (longueur*largeur*hauteur) : 2000*400*1800mm<\/p>\n<div id=\"attachment_15723\" class=\"wp-caption aligncenter\" style=\"width: 624px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-15723 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-1-2007-Clause-5.6.3.2.png\" sizes=\"(max-width: 614px) 100vw, 614px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-1-2007-Clause-5.6.3.2.png 614w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-1-2007-Clause-5.6.3.2-400x79.png 400w\" alt=\"\" width=\"614\" height=\"122\" aria-describedby=\"caption-attachment-15723\" title=\"\"><\/p>\n<p id=\"caption-attachment-15723\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60245-1 : 2007 Clause 5.6.3.2<\/span><\/p>\n<\/div>\n<div id=\"attachment_15724\" class=\"wp-caption aligncenter\" style=\"width: 619px;\">\n<p><img decoding=\"async\" class=\"wp-image-15724 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-2-1998-Clause-3.2-Figure-2.png\" sizes=\"(max-width: 609px) 100vw, 609px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-2-1998-Clause-3.2-Figure-2.png 609w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/02\/IEC-60245-2-1998-Clause-3.2-Figure-2-311x400.png 311w\" alt=\"\" width=\"609\" height=\"784\" aria-describedby=\"caption-attachment-15724\" title=\"\"><\/p>\n<p id=\"caption-attachment-15724\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60245-2 : 1998 Clause 3.2 Figure 2<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The WDT-3 Static Flexibility Test Machine for Flexible Cables fully meet fully meet IEC 60245-1:2008 Clause 5.6.3.2 (GB\/T 5013.1-2008 Clause 5.6.3.2), IEC 63294 (IEC 60245-2 Clause 3.2 Figure 2 (GB\/T 5013.2-2008 Clause 3.2 Figure 2)), IEC 60227-1:2024 Clause 5.6.3.2 (GB\/T 5023.1-2008 Clause 5.6.3.2), IEC 63294 (IEC 60227-2:2008 Clause 3.2 Figure 2 (GB\/T 5023.2-2008 Clause 3.2 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3749,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[536],"class_list":["post-2842","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-wdt-3"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts\/2842","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/comments?post=2842"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/posts\/2842\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/media\/3749"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/media?parent=2842"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/categories?post=2842"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/fr\/wp-json\/wp\/v2\/tags?post=2842"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}