Spektroradiometer CCD Kelas Ilmiah

Tinggalkan pesan

=
Deskripsi Produk

LMS-9500 Scientific Grade High Accuracy CCD Array Color Spectroradiometer fully meets Energy Star IESNA LM-79, GB/T24824 and other related standards. It can test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and it uses unique stray light control technology, wide dynamic linear technology, precision CCD electronic drive technology and complex matrix software technology. The instrument is traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST standards.

Standar:
CIE 177 "Rendering Warna Sumber Cahaya LED Putih"
CIE84 "Pengukuran fluks cahaya"
CIE-13.3 "Metode Mengukur dan Menentukan Properti Rendering Warna Sumber Cahaya"
LM-79-19 "Pengukuran Optik dan Listrik Produk Pencahayaan Solid State"
IESNA LM-63-2 "Format File Standar IESNA untuk Transfer Elektronik Data Fotometrik dan Informasi Terkait"
IES LM-80-08 "Mengukur Pemeliharaan Lumen Sumber Cahaya LED"
ANSI-C78.377 "Spesifikasi Kromatisitas produk Pencahayaan Solid State untuk Lampu Listrik"
(UNI EROPA) 2019/2015 "PERATURAN YANG DIDELEGASIKAN OLEH KOMISI"

Spesifikasi:
• CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector (LMS-9500CSWIR uses InGaAs)
- Akurasi panjang gelombang spektral: ± 0,2nm, Resolusi: ± 0,1nm, Langkah-langkah pemindaian sampel: ± 0,1nm
- Akurasi koordinat kromatisitas (Δx, Δy): ±0,0015 (di bawah Lampu Standar A)
- CCT suhu warna yang berkorelasi: 1, 500K ~ 100, 000K, akurasi CCT: ± 0,2%
- Rentang indeks rendering warna: 0 ~ 100,0, Akurasi: ± (0,3%rd ± 0,3)
• Photometric linear: ±0.2%, Stray light: <0.015%(600nm) and <0.03% (435nm)
- Waktu integrasi: 0.1ms-60s
- Dapat mengukur suhu di dalam dan di luar bola yang terintegrasi
• Flux testing method: spectrum, photometric, spectrum with photometric revision

Model LISUN LMS-9500C LMS-9500CUV-VIS LMS-9500CVIS-NIR LMS-9500CSWIR
Panjang gelombang 350-800nm 200-800nm 350-1050nm 800-1700nm

LISUN LPCE-2 (LMS-9500C) Spektroradiometer Presisi Tinggi yang Mengintegrasikan Sistem Sphere - Pertanyaan yang Sering Diajukan Purna Jual (FAQ).
LISUN LPCE-2 (LMS-9500C) Sistem Spektroradiometer Presisi Tinggi yang Mengintegrasikan Sistem Bola berada di pasar selama lebih dari 10 tahun, tim layanan insinyur LISUN telah merangkum sebagian besar Pertanyaan dan Jawaban Purna Jual di tautan di atas. Harap baca dengan seksama, Anda dapat menyelesaikan sebagian besar masalah sendiri jika Anda memiliki beberapa pertanyaan saat menggunakan instrumen. LISUN akan terus memperbarui halaman ini dan lebih banyak FAQ dapat ditemukan di tautan topik ini.