{"id":2327,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/high-precision-spectroradiometer-integrating-sphere-system-2\/"},"modified":"2025-07-01T17:00:38","modified_gmt":"2025-07-01T09:00:38","slug":"spektroradiometer-presisi-tinggi-yang-mengintegrasikan-sistem-bola-2","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/id\/produk\/spektroradiometer-presisi-tinggi-yang-mengintegrasikan-sistem-bola-2\/","title":{"rendered":"LM-79 Sistem Sphere Pengintegrasian Fotometrik dan Listrik"},"content":{"rendered":"<p>Sistem Pengujian LED Spektroradiometer Spektroradiometer Sphere Integrasi LPCE-2 adalah untuk pengukuran cahaya LED tunggal dan produk pencahayaan LED. Kualitas LED harus diuji dengan memeriksa parameter fotometrik, kolorimetrik, dan kelistrikannya. Menurut <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a>,\u00a0 <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a><span style=\"color: #000000;\">,<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/02\/ANSI-IES-LM-79-24.pdf\" target=\"_blank\" rel=\"noopener\"> IES LM-79-24<\/a>,<\/span>\u00a0<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-79-19<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/OPTICAL-ENGINEERING-49-3-033602-2010-COLOR-QUALITY-SCALE-CQS-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">Optical-Engineering-49-3-033602<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">PERATURAN YANG DIDELEGASIKAN OLEH KOMISI (EU) 2019\/2015<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES-LM-80<\/a>\u00a0Dan <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a><span style=\"color: #000000;\">,<\/span> merekomendasikan untuk menggunakan spektroradiometer array dengan bola pengintegrasi untuk menguji produk SSL. Sistem LPCE-2 diaplikasikan dengan Spektroradiometer CCD Presisi Tinggi LMS-9000C atau Spektroradiometer CCD Kelas Ilmiah LMS-9500C, dan bola pengintegrasian cetakan dengan alas dudukan. Bola ini lebih bulat dan hasil pengujiannya lebih akurat daripada bola integrasi tradisional.<\/p>\n<p><strong>Standar:<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"Rendering Warna Sumber Cahaya LED Putih\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"Pengukuran fluks cahaya\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"Metode Mengukur dan Menentukan Properti Rendering Warna Sumber Cahaya\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Pengukuran Optik dan Listrik Produk Pencahayaan Solid State\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"Format File Standar IESNA untuk Transfer Elektronik Data Fotometrik dan Informasi Terkait\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"Mengukur Pemeliharaan Lumen Sumber Cahaya LED\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"Spesifikasi Kromatisitas produk Pencahayaan Solid State untuk Lampu Listrik\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\"> (UNI EROPA) 2019\/2015<\/a> \"PERATURAN YANG DIDELEGASIKAN OLEH KOMISI\"<\/p>\n<p><strong>Pengukuran:<br \/>\n<\/strong>- Kolorimetri: Koordinat kromatisitas, CCT, Rasio Warna, Panjang Gelombang Puncak, Setengah Bandwidth, Panjang Gelombang Dominan, Kemurnian Warna, CRI, CQS, TM-30 (Rf, Rg), Uji Spektrum<br \/>\n- Fotometrik: Fluks Bercahaya, Efisiensi Bercahaya, Daya Radiasi, WPE, EQE, EEI, Kelas Efisiensi Energi, Fluks Pupil, Efisiensi Fluks Pupil, Faktor Pupil, Fluks Kirtopik, Lampu Penumbuh Tanaman PAR dan PPF<br \/>\n- Listrik: Tegangan, Arus, Daya, Faktor Daya, Faktor Perpindahan, Harmonik (Opsional)<br \/>\n- Uji Penuaan Lampu LED menurut LM-80: Fluks VS waktu, CCT VS waktu, CRI VS waktu, Daya VS waktu, Faktor Daya VS waktu, Arus VS waktu, dan Efisiensi Fluks VS waktu.<\/p>\n<p>Opsi: LPCE-2 (LMS-9000C) atau LPCE-2 (LMS-9500C) bekerja dengan IS-1.5MT <a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/constant-temperature-integrating-sphere.html\" target=\"_blank\" rel=\"noopener\">Bola Pengintegrasian Suhu Konstan<\/a> Dan <a href=\"https:\/\/www.lisungroup.com\/products\/cfl-testing-instruments\/multiplex-temperature-tester.html\" target=\"_blank\" rel=\"noopener\">Penguji Suhu Multipleks TMP-8<\/a> dapat sepenuhnya memenuhi <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/ies-lm-82-12-standard-free-download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-82<\/a><\/p>\n<p><strong>Konfigurasi Sistem LPCE-2 (LMS-9000C) Presisi Tinggi (Sangat cocok untuk Produsen Menengah &amp; Kecil atau Lab Uji Umum):<br \/>\n<\/strong><a href=\"https:\/\/www.lisungroup.com\/products\/spectroradiometer\/high-precision-ccd-spectroradiometer.html\" target=\"_blank\" rel=\"noopener noreferrer\">Spektroradiometer CCD Presisi Tinggi\u00a0<\/a>(LMS-9000C), <a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/optical-fiber.html\" target=\"_blank\" rel=\"noopener noreferrer\">Serat Optik<\/a>\u00a0(CFO-1,5M),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-power-meter-high-accuracy-model.html\" target=\"_blank\" rel=\"noopener noreferrer\">Pengukur Daya Digital<\/a> (LS2050B\/LS2050C\/LS2012), <a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-cc-and-cv-dc-power-supply.html\" target=\"_blank\" rel=\"noopener noreferrer\">Sumber Daya DC<\/a>\u00a0(Seri DC),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/ac-power-source.html\" target=\"_blank\" rel=\"noopener noreferrer\">Sumber Daya AC<\/a> (LSP-500VARC atau LSP-500VARC-Pst), <a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_blank\" rel=\"noopener noreferrer\">Mengintegrasikan Bola<\/a>\u00a0(IS-1.5MA dan IS-0.3M), <a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/standard-light-source.html\" target=\"_blank\" rel=\"noopener\">Sumber Cahaya Standar<\/a> (SLS-50W dan SLS-10W), <a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/19inch-standard-instrument-cabinet.html\" target=\"_blank\" rel=\"noopener\">Kabinet 19 Inch<\/a> (KASUS-19IN). Anda dapat mengunduh PDF terperinci di sini: <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/high-precision-spectroradiometer-integrating-sphere-system-9000c.pdf\" target=\"_blank\" rel=\"noopener\">LPCE-2 (LMS-9000C) Spektroradiometer CCD Presisi Tinggi yang Mengintegrasikan Sistem Sphere Brosur<\/a><\/p>\n<p><strong>Spesifikasi:<\/strong><br \/>\n- Akurasi Panjang Gelombang Spektral: \u00b1 0,3nm, Reproduktifitas Panjang Gelombang: \u00b1 0,1nm<br \/>\n- Langkah-langkah Pemindaian Sampel: \u00b1 0.1nm<br \/>\n- Akurasi Koordinat Kromatisitas (\u0394x, \u0394y): \u00b10,002 (di bawah Lampu Standar A)<br \/>\n- CCT Suhu Warna Terkorelasi: 1.500K ~ 100.000K, Akurasi CCT: \u00b1 0,3%<br \/>\n- Rentang Indeks Rendering Warna: 0 ~ 100,0, Akurasi: \u00b1 (0,3%rd \u00b1 0,3)<br \/>\n- Rentang Fluks Bercahaya: 0,01-200.000lm; Akurasi linier fotometrik: \u00b1 0,5%<br \/>\n- Cahaya yang menyimpang: &lt;0,015% (600nm) dan &lt;0,03% (435nm)<br \/>\n- Waktu Integrasi: 0,1 ~ 10.000 ms<br \/>\n- Dapat mengukur suhu di dalam dan di luar bola yang terintegrasi<br \/>\n- Metode pengujian fluks: spektrum, fotometrik, dan spektrum dengan revisi fotometrik<br \/>\n- Sistem ini menyertakan perangkat lampu tambahan dan perangkat lunak menyertakan fungsi koreksi koefisien penyerapan sendiri<br \/>\n- Dapat mengukur suhu di dalam dan di luar bola yang terintegrasi<br \/>\n- Terhubung dengan PC melalui kabel USB. Perangkat lunak versi bahasa Inggris dapat berjalan di Win7, Win8, Win10, Win11 (driver bersertifikat Microsoft)<br \/>\n- Laporan Fotometri, Kolorimetri, dan Listrik LM-79 dapat diekspor PDF dan laporan uji Pemeliharaan Optik LED dapat diekspor Excel atau PDF<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 20%;\"><strong>Model LISUN<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000C<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000CUV-VIS<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000CVIS-NIR<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 20%;\"><strong>Panjang gelombang<\/strong><\/td>\n<td style=\"width: 20%;\">350-800nm<\/td>\n<td style=\"width: 20%;\">200-800nm<\/td>\n<td style=\"width: 20%;\">350-1050nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Konfigurasi Sistem LPCE-2 (LMS-9500C) Kelas Ilmiah (Sangat cocok untuk Pabrik Besar &amp; Menengah atau Lab Uji Pihak Ketiga):\u00a0<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/products\/spectroradiometer\/scientific-grade-ccd-spectroradiometer.html\" target=\"_blank\" rel=\"noopener noreferrer\">Spektroradiometer CCD Kelas Ilmiah <\/a>(LMS-9500C), <a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/optical-fiber.html\" target=\"_blank\" rel=\"noopener noreferrer\">Serat Optik<\/a>\u00a0(CFO-1,5M),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-power-meter-high-accuracy-model.html\" target=\"_blank\" rel=\"noopener noreferrer\">Pengukur Daya Digital<\/a> (LS2050C), <a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-cc-and-cv-dc-power-supply.html\" target=\"_blank\" rel=\"noopener noreferrer\">Sumber Daya DC<\/a>\u00a0(Seri DC),\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/ac-power-source.html\" target=\"_blank\" rel=\"noopener noreferrer\">Sumber Daya AC<\/a> (LSP-500VARC atau LSP-500VARC-Pst), <a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_blank\" rel=\"noopener noreferrer\">Mengintegrasikan Bola<\/a>\u00a0(IS-1.5MA dan IS-0.3M), <a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/standard-light-source.html\" target=\"_blank\" rel=\"noopener\">Sumber Cahaya Standar<\/a> (SLS-50W dan SLS-10W), <a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/19inch-standard-instrument-cabinet.html\" target=\"_blank\" rel=\"noopener\">Kabinet 19 Inch<\/a> (KASUS-19IN). Anda dapat mengunduh PDF detailnya di sini: <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/scientific-grade-ccd-spectroradiometer-integrating-sphere-system-9500.pdf\" target=\"_blank\" rel=\"noopener\">LPCE-2 (LMS-9500C) Spektroradiometer CCD Kelas Ilmiah yang Mengintegrasikan Sistem Sphere Brosur<\/a><\/p>\n<p><strong>Spesifikasi:<\/strong><br \/>\n- Detektor CCD: Detektor dengan sensitivitas tinggi yang didinginkan dengan Hamamatsu TE (Suhu: -10\u00b0C \u00b1 0,05\u00b0C)<br \/>\n- Akurasi panjang gelombang spektral: \u00b1 0,2nm, Resolusi: \u00b1 0,1nm, Langkah-langkah pemindaian sampel: \u00b1 0,1nm<br \/>\n- Akurasi koordinat kromatisitas (\u0394x, \u0394y): \u00b10,0015 (di bawah Lampu Standar A)<br \/>\n- CCT suhu warna yang berkorelasi: 1, 500K ~ 100, 000K, akurasi CCT: \u00b1 0,2%<br \/>\n- Rentang indeks rendering warna: 0 ~ 100,0, Akurasi: \u00b1 (0,3%rd \u00b1 0,3)<br \/>\n- Akurasi linier fotometrik: \u00b1 0,2%<br \/>\n- Cahaya yang menyimpang: &lt;0,015% (600nm) dan &lt;0,03% (435nm)<br \/>\n- Waktu integrasi: 0.1ms-60s<br \/>\n- Dapat mengukur suhu di dalam dan di luar bola yang terintegrasi<br \/>\n- Metode pengujian fluks: spektrum, fotometrik, dan spektrum dengan revisi fotometrik<br \/>\n- Sistem ini menyertakan perangkat lampu tambahan dan perangkat lunak menyertakan fungsi koreksi koefisien penyerapan sendiri<br \/>\n- Hubungkan dengan PC melalui kabel USB. Perangkat lunak versi bahasa Inggris dapat dijalankan di Win7, Win8, Win10, Win11 (driver bersertifikat Microsoft)<br \/>\n- Laporan Fotometri, Kolorimetri, dan Listrik LM-79 dapat diekspor PDF dan laporan uji Pemeliharaan Optik LED dapat diekspor Excel atau PDF<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 20%;\"><strong>Model LISUN<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500C<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CUV-VIS<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9500CVIS-NIR<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 20%;\"><strong>Panjang gelombang<\/strong><\/td>\n<td style=\"width: 20%;\">350-800nm<\/td>\n<td style=\"width: 20%;\">200-800nm<\/td>\n<td style=\"width: 20%;\">350-1050nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9000c-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-2 (LMS-9000C) Spektroradiometer Presisi Tinggi yang Mengintegrasikan Sistem Sphere - Pertanyaan yang Sering Diajukan Purna Jual (FAQ).<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-2 (LMS-9000C) Sistem Spektroradiometer Presisi Tinggi yang Mengintegrasikan Sistem Bola berada di pasar selama lebih dari 10 tahun, tim layanan insinyur LISUN telah merangkum sebagian besar Pertanyaan dan Jawaban Purna Jual di tautan di atas. Harap baca dengan seksama, Anda dapat menyelesaikan sebagian besar masalah sendiri jika Anda memiliki beberapa pertanyaan saat menggunakan instrumen. LISUN akan terus memperbarui halaman ini dan lebih banyak FAQ dapat ditemukan di tautan topik ini.<\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9500b-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html \" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-2 (LMS-9500C) Spektroradiometer Presisi Tinggi yang Mengintegrasikan Sistem Sphere - Pertanyaan yang Sering Diajukan Purna Jual (FAQ).<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-2 (LMS-9500C) Sistem Spektroradiometer Presisi Tinggi yang Mengintegrasikan Sistem Bola berada di pasar selama lebih dari 10 tahun, tim layanan insinyur LISUN telah merangkum sebagian besar Pertanyaan dan Jawaban Purna Jual di tautan di atas. Harap baca dengan seksama, Anda dapat menyelesaikan sebagian besar masalah sendiri jika Anda memiliki beberapa pertanyaan saat menggunakan instrumen. LISUN akan terus memperbarui halaman ini dan lebih banyak FAQ dapat ditemukan di tautan topik ini.<\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9000-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-2 (LMS-9000B\/A) Spektroradiometer Presisi Tinggi yang Mengintegrasikan Sistem Sphere - Pertanyaan yang Sering Diajukan Purna Jual (FAQ).<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-2 (LMS-9000B \/ A) Sistem Spektroradiometer Presisi Tinggi yang Mengintegrasikan Sistem Bola berada di pasar selama lebih dari 10 tahun, tim layanan insinyur LISUN telah merangkum sebagian besar Pertanyaan dan Jawaban Purna Jual di tautan di atas. Harap baca dengan seksama, Anda dapat menyelesaikan sebagian besar masalah sendiri jika Anda memiliki beberapa pertanyaan saat menggunakan instrumen. LISUN akan terus memperbarui halaman ini dan lebih banyak FAQ dapat ditemukan di tautan topik ini.<\/p>","protected":false},"excerpt":{"rendered":"<p>LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED\u2019s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84,\u00a0 CIE-13.3, IES LM-79-24,\u00a0IES LM-79-19, Optical-Engineering-49-3-033602, COMMISSION DELEGATED REGULATION (EU) 2019\/2015, IESNA LM-63-2, IES-LM-80\u00a0and ANSI-C78.377, it recommends to using an array [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3432,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[27],"class_list":["post-2327","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lpce-2lms-9000"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts\/2327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/comments?post=2327"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts\/2327\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/media\/3432"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/media?parent=2327"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/categories?post=2327"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/tags?post=2327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}