{"id":2341,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/compact-goniophotometer\/"},"modified":"2025-07-01T18:00:49","modified_gmt":"2025-07-01T10:00:49","slug":"compact-goniophotometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/id\/produk\/compact-goniophotometer\/","title":{"rendered":"Goniofotometer Ringkas dengan kamar gelap"},"content":{"rendered":"<p>The LSG-1200A compact <a href=\"https:\/\/www.lisungroup.com\/products\/goniophotometer\/\" target=\"_blank\" rel=\"noopener\">goniofotometer<\/a> is used to measure the luminous intensity distribution curve, intensity data, beam angle and other photometric parameters for Chip LED, LED Module, LED Spotlight and all other light which spread angle is no more than 180 degrees.<\/p>\n<p>Optional function: The LSG-1200A can work with a <a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-power-meter-ac-model.html\" target=\"_blank\" rel=\"noopener noreferrer\">Pengukur Daya Digital<\/a>\u00a0(<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-power-meter-ac-dc-model.html\" target=\"_blank\" rel=\"noopener\">LS2012\u00a0DC &amp; AC Power Meter<\/a> atau\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-power-meter-high-accuracy-model.html\" target=\"_blank\" rel=\"noopener\">LS2050 Harmonic Analyzer Power Meter<\/a>) and LSP-500VARC <a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/ac-power-source.html\" target=\"_blank\" rel=\"noopener noreferrer\">Sumber Daya AC<\/a>.<\/p>\n<p><strong>Standar: Standar<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Pengukuran Optik dan Listrik Produk Pencahayaan Solid State\"<br \/>\n<a href=\"https:\/\/www.lisungroup.cn\/wp-content\/uploads\/2019\/07\/EN13032-1-2004AC-2005.pdf\" target=\"_blank\" rel=\"noopener\">EN13032-1<\/a> \"Cahaya dan pencahayaan - Pengukuran dan penyajian data fotometrik lampu dan luminer - Bagian 1: Pengukuran dan format file; Versi Jerman EN 13032-1: 2004 + A1: 2012\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CIE-121-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-121<\/a> \u201cThe Photometry and Goniophotometry of Luminaires\u201d<\/p>\n<p><strong>Spesifikasi:<br \/>\n<\/strong>\u2022 Meets the requirements of IEC, CIE and<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\"> LM-79<\/a> standards<br \/>\n\u2022 Measures beam angle automatically: 1\/2 max intensity angle as well as 1\/4 max intensity angle, 3\/4 max intensity angle and 1\/10 max intensity angle which meets the special requirements.<br \/>\n\u2022 Measured data is matched with international standard form (IES, etc) and can be applied for lighting design by other lighting design software such as DiaLux<br \/>\n\u2022 Maximum size of luminaires under test: max \u03a6180mm*160mm (Diameter*Depth)<br \/>\n\u2022 Test range of light intensity: 0.1\uff5e30,000cd. Accuracy of the detector: Class A<br \/>\n\u2022 The distance between the luminaire under test and the detector is 316mm or 1000mm<br \/>\n\u2022 Angle interval: Horizontal angle: 1\u00b0\/5\u00b0\/10\u00b0\/15\u00b0\/22.5\u00b0\/30\u00b0\/45\u00b0\/90\u00b0, Vertical angle: 0.5\u00b0\/2\u00b0\/1.5\u00b0<br \/>\n\u2022 The LSG-1200A horizontal automatic rotating with an angle 0\u00b0~360\u00b0 (C) and Vertical automatic rotating with an angle -90\u00b0~+90\u00b0 (Gamma)<br \/>\n\u2022 Test accuracy of angle: \u00b10.2\u00b0<br \/>\n\u2022 LSG-1200A can be used together with a CCD Spectroradiometer to test spatial CCT Distribution and other Spectral color parameters. We call this system \u201cGoniospectroradiometer (LSG-1200ACCD)\u201d. The LSG-1200ACCD Goniospectroradiometer = <a href=\"https:\/\/www.lisungroup.com\/products\/goniophotometer\/compact-goniophotometer.html\" target=\"_blank\" rel=\"noopener noreferrer\" data-cke-saved-href=\"https:\/\/lisungroup.com\/product-id-210.html\">LSG-1200A Goniophotometer System<\/a> \u00a0+\u00a0 <a href=\"https:\/\/www.lisungroup.com\/products\/led-test-instruments\/high-precision-spectroradiometer-integrating-sphere-system.html\" target=\"_blank\" rel=\"noopener noreferrer\" data-cke-saved-href=\"https:\/\/lisungroup.com\/product-id-340.html\">LPCE-2 Mengintegrasikan Sistem Spektroradiometer bola<\/a>. Please click to download the <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/07\/compact-goniospectroradiometer.pdf\" data-cke-saved-href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/moving-detector-goniospectroradiometer.pdf\" target=\"_blank\" rel=\"noopener\">LSG-1200ACCD Brochure<\/a><\/p>\n<p><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lsg-1200a-compact-goniophotometer-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\">LISUN LSG-1200A Compact Goniophotometer \u2013 After-sales Frequently Asked Questions (FAQ)<\/a><\/span><br \/>\n<\/strong>LISUN LSG-1200A Compact Goniophotometer were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>The LSG-1200A compact goniophotometer is used to measure the luminous intensity distribution curve, intensity data, beam angle and other photometric parameters for Chip LED, LED Module, LED Spotlight and all other light which spread angle is no more than 180 degrees. Optional function: The LSG-1200A can work with a Digital Power Meter\u00a0(LS2012\u00a0DC &amp; AC Power [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3500,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[99],"class_list":["post-2341","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lsg-1200a"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts\/2341","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/comments?post=2341"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts\/2341\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/media\/3500"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/media?parent=2341"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/categories?post=2341"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/tags?post=2341"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}