{"id":2544,"date":"2025-06-19T19:36:45","date_gmt":"2025-06-19T11:36:45","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/lux-meter-brightness-meter-ppfd-meter-uv-irradiance-meter\/"},"modified":"2025-06-25T17:51:34","modified_gmt":"2025-06-25T09:51:34","slug":"lux-meter-brightness-meter-ppfd-meter-uv-irradiance-meter","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/id\/produk\/lux-meter-brightness-meter-ppfd-meter-uv-irradiance-meter\/","title":{"rendered":"Lux Meter | Brightness Meter | PPFD Meter | UV Irradiance Meter"},"content":{"rendered":"<p>The PHOTO-200 series Lux Meter | Brightness Meter | PPFD Meter | UV Irradiance Meter use high-precision linear optoelectronic sensor, which has the characteristics of lightweight, stable performance, high accuracy, high cost performance, and easy carrying. Widely used on-site lighting measurement, the research and development of light source products, quality monitoring of production lines, and plant factories.<\/p>\n<p><b>Spesifikasi:<\/b><\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Detector Accuracy<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">Class A (\u00b1 4%reading \u00b1 1 reading)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center;\" width=\"133\">Reproducibility<\/td>\n<td style=\"width: 75.8312%; text-align: center;\" width=\"425\">\u00b10.5%<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Display method<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">Touch screen (can expand: PC, mobile APP)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Screen Size<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">1.54 \u201cIPS HD LCD touch screen<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Screen type<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">180 degrees rotation<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Communication method<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">USB\u3001Bluetooth<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Charging interface<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">Type-C<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Power supply<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">1600mA lithium battery<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Continuous work time<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">It can be used continuously for 12 hours after one charge<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Product Size<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">65mm*60mm*60mm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Product weight<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">Aluminum alloy body, 100g<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 24.0409%; text-align: center; vertical-align: middle;\" width=\"133\">Secondary development<\/td>\n<td style=\"width: 75.8312%; text-align: center; vertical-align: middle;\" width=\"425\">Support<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Order Model<\/strong>:<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\"><strong>Model LISUN<\/strong><\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\"><strong>Nama Produk<\/strong><\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\"><strong>Test Parameters and Specification<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\">PHOTO-200<\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\">Pocket Illuminance Meter<\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\">Illuminance lux test range (380-780nm): 0.1-500,000lx (\u00b10.1lx), upper and lower limit settings, sorting tests, optical change curves (PC software), illuminance, average illuminance, maximum illuminance, minimum illuminance, point illumination, illuminance transmission (%)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\">PHOTO-200L<\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\">Pocket Brightness Meter<\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\">Brightness test range (380-780nm): 0.1-500,000cd\/m\u00b2 (\u00b10.1cd\/m\u00b2), upper and lower limit settings, sorting test, light change curve (PC software), brightness, average brightness, maximum brightness, minimum brightness, points brightness, brightness transmission (%)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\">PHOTO-200P<\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\">PPFD Sensor and Lux Meter<\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\">Illuminance lx, PPFD umol\/m\u00b2.s (400-700nm) test range: 0.1-500,000umol\/m\u00b2.s (\u00b10.01umol\/m\u00b2.s) , Up and down limit settings, sorting tests, optical change curves (PC software), PPFD, average PPFD, maximum PPFD, minimum PPFD, energy, transmission ratio (%), testing time<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\">PHOTO-200DLI<\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\">PPFD Sensor\uff08DLI)<\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\">PPFD umol\/m\u00b2.s (400-700nm) test range: 0.1-500,000umol\/m\u00b2.s (\u00b10.01umol\/m\u00b2.s), total amount of effective radiation umol\/m\u00b2.d<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\">PHOTO-200B<\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\">Blue Light Irradiance (460nm)<\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\">Irradiance \u03bcW\/cm\u00b2 (peak: 460nm) test range: 0.1-200,000\u03bcW\/cm\u00b2 (\u00b10.1\u03bcW\/cm\u00b2), upper and lower limit settings, sorting tests, optical change curves (PC software), irradiation, average Irradiance degree, maximum Irradiance, minimum Irradiance degree, minimum Irradiance, degree Blu -ray energy \u03bcJ\/cm\u00b2, Irradiance transmission ratio (%), testing time<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\">PHOTO-200UV<\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\">UV Irradiance<\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\">Irradiance \u03bcW\/cm\u00b2(222 nm or 254nm or 365nm) test range: 0.1-500,000\u03bcW\/cm\u00b2 (\u00b10.01\u03bcW\/cm\u00b2), upper and lower limit settings, sorting tests, optical change curves (PC software), Irradiance degree, average Irradiance degree, maximum Irradiance, minimum Irradiance, UV energy, radiation transmission ratio (%), testing time<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\">PHOTO-200UVZ<\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\">UV Irradiance (Multiband)<\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\">Irradiance \u03bcW\/cm\u00b2(254nm and 365nm) test range: 0.1-500,000\u03bcW\/cm\u00b2 (\u00b10.01\u03bcW\/cm\u00b2), upper and lower limit settings, sorting tests, optical change curve (PC software), radiation, average radiation, maximum radiation, minimum radiation, UV energy, radical transmission ratio (%), testing time<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\">PHOTO-200R<\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\">Red Light Irradiance (650nm)<\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\">Irradiance \u03bcW\/cm\u00b2 (Peak: 650nm) test range: 0.1-200,000\u03bcW\/cm\u00b2 (\u00b10.1\u03bcW\/cm\u00b2), upper and lower limit settings, sorting tests, light change curve (PC software), irradiation, average radiation degree, maximum radiation, minimum radiation, red light energy \u03bcJ\/cm\u00b2, radiation transmission ratio (%), testing time<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\">PHOTO-200IR<\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\">nIR Irradiance<\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\">Irradiance \u03bcW\/cm\u00b2 (850 nm or 940nm) test range: 0.1-500,000\u03bcW\/cm\u00b2 (\u00b10.01\u03bcW\/cm\u00b2)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 13.6829%; text-align: center; vertical-align: middle;\" width=\"94\">PHOTO-200IRZ<\/td>\n<td style=\"width: 14.9616%; text-align: center; vertical-align: middle;\" width=\"102\">nIR Irradiance (Multiband)<\/td>\n<td style=\"width: 71.2276%; text-align: center; vertical-align: middle;\" width=\"498\">Irradiance \u03bcW\/cm\u00b2 (850 nm and 940nm) test range: 0.1-500,000\u03bcW\/cm\u00b2 (\u00b10.01\u03bcW\/cm\u00b2)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>The PHOTO-200 series Lux Meter | Brightness Meter | PPFD Meter | UV Irradiance Meter use high-precision linear optoelectronic sensor, which has the characteristics of lightweight, stable performance, high accuracy, high cost performance, and easy carrying. Widely used on-site lighting measurement, the research and development of light source products, quality monitoring of production lines, and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3556,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[297],"class_list":["post-2544","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-photo-200"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts\/2544","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/comments?post=2544"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts\/2544\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/media\/3556"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/media?parent=2544"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/categories?post=2544"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/tags?post=2544"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}