{"id":2854,"date":"2025-06-19T19:41:24","date_gmt":"2025-06-19T11:41:24","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60884-1-iec-60669-1-clause-12-3-11-screwless-terminals-electrical-and-thermal-stresses-test-device\/"},"modified":"2025-06-25T13:16:25","modified_gmt":"2025-06-25T05:16:25","slug":"iec-60884-1-iec-60669-1-clause-12-3-11-screwless-terminals-electrical-and-thermal-stresses-test-device","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/id\/produk\/iec-60884-1-iec-60669-1-clause-12-3-11-screwless-terminals-electrical-and-thermal-stresses-test-device\/","title":{"rendered":"IEC 60884-1 IEC 60669-1 Clause 12.3.11 Screwless Terminals Electrical and Thermal Stresses Test Device"},"content":{"rendered":"<p>The JCY-1 Screwless Terminals Electrical and Thermal Stresses Test Device fully comply with Clause 12.3.11 of IEC 60884-1:2022 (GB\/T 2099.1-2021) and IEC 60669-1:2017 (GB\/T 16915.1-2024). During operation, the test current is connected according to the standard. After a certain period, the voltage drop is measured (judgment criterion: the voltage drop is not greater than 22.5mV) to inspect whether the screwless terminals can withstand the electrical and thermal stresses that occur during normal use.<\/p>\n<p><strong>Standar:\u00a0<\/strong><br \/>\nIEC 60884-1 (GB\/T 2099.1) \u201cPlugs and socket-outlets for household and similar purposes \u2013 Part 1: General requirements\u201d Clause 12.3.11<br \/>\nIEC 60669-1 (GB\/T 16915.1) \u201cSwitches for household and similar fixed-electrical installations \u2013 Part 1: General requirements\u201d<\/p>\n<p><strong>Spesifikasi:<br \/>\n<\/strong>\u2022\u00a0Voltage meter range: 0~50mV (3%\u00b11A)<br \/>\n\u2022\u00a0Current meter range: 0~30A (3%\u00b11mV)<br \/>\n\u2022\u00a0Supply voltage: 4~12V<br \/>\n\u2022\u00a0Supply current: 0~30A<br \/>\n\u2022\u00a0Test cycle setting: 0~9,999 times<\/p>\n<p><strong>Note: The JCY-1 Screwless Terminals withstand the electrical and Thermal stresses Test Device is typically used in conjunction with the <a href=\"https:\/\/www.lisungroup.com\/products\/plug-and-switch-testing\/iec-60884-1-iec-60669-1-clause-12-3-12-screwless-terminals-bending-test-device.html\" target=\"_blank\" rel=\"noopener\">JCY-2 Screwless Terminals Bending Test Device <\/a>.<\/strong><\/p>\n<div id=\"attachment_14508\" class=\"wp-caption aligncenter\" style=\"width: 769px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14508 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/IEC-60884-1-Clause12.3.11.png\" sizes=\"(max-width: 759px) 100vw, 759px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/IEC-60884-1-Clause12.3.11.png 759w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/05\/IEC-60884-1-Clause12.3.11-400x285.png 400w\" alt=\"\" width=\"759\" height=\"540\" aria-describedby=\"caption-attachment-14508\" title=\"\"><\/p>\n<p id=\"caption-attachment-14508\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60884 1 Clause12.3.1<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The JCY-1 Screwless Terminals Electrical and Thermal Stresses Test Device fully comply with Clause 12.3.11 of IEC 60884-1:2022 (GB\/T 2099.1-2021) and IEC 60669-1:2017 (GB\/T 16915.1-2024). During operation, the test current is connected according to the standard. After a certain period, the voltage drop is measured (judgment criterion: the voltage drop is not greater than 22.5mV) [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3385,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[548],"class_list":["post-2854","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-jcy-1"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts\/2854","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/comments?post=2854"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts\/2854\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/media\/3385"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/media?parent=2854"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/categories?post=2854"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/tags?post=2854"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}