{"id":2903,"date":"2025-06-19T19:42:03","date_gmt":"2025-06-19T11:42:03","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-60811-1-2-clause-8-2-and-8-3-iec-60335-1-clause-22-32-oxygen-bomb-air-aging-test-chamber\/"},"modified":"2025-06-25T12:03:55","modified_gmt":"2025-06-25T04:03:55","slug":"iec-60811-1-2-clause-8-2-and-8-3-iec-60335-1-clause-22-32-oxygen-bomb-air-aging-test-chamber","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/id\/produk\/iec-60811-1-2-clause-8-2-and-8-3-iec-60335-1-clause-22-32-oxygen-bomb-air-aging-test-chamber\/","title":{"rendered":"IEC 60811-1-2 Clause 8.2 and 8.3 | IEC 60335-1 Clause 22.32 Oxygen Bomb Air Aging Test Chamber"},"content":{"rendered":"<p>The LS-B48 Oxygen Bomb Air Aging Test Chamber is designed and manufactured in full accordance with IEC 60811-401, IEC 60811-412, IEC 60811-1-2 Clause 8.2 and 8.3 (GB\/T 2951.12 Clause 8.2 and 8.3)\uff0cIEC 60335-1 Clause 22.32 (GB\/T 4706.1 Clause 22.32)\uff0cGB\/T 5013.1 and IEC 60245-1. It is suitable for aging experiments of medical device materials, wires and cables, rubber (plastic, artificial leather) insulation layers and sheaths, and other polymer materials under the specified pressure and temperature in the medium of oxygen and compressed air.<\/p>\n<p><strong>Standar:<\/strong><br \/>\nIEC 60811-401 &#8220;Electric and optical fibre cables &#8211; Test methods for non-metallic materials &#8211; Part 401: Miscellaneous tests &#8211; Thermal ageing methods &#8211; Ageing in an air oven&#8221;<br \/>\nIEC 60811-412 &#8220;Electric and optical fibre cables &#8211; Test methods for non-metallic materials &#8211; Part 412: Miscellaneous tests &#8211; Thermal ageing methods &#8211; Ageing in an air bomb&#8221;<br \/>\nIEC 60811-1-2 (GB\/T 2951.12) &#8220;Common test methods for insulating and sheathing materials of electric cables &#8211; Part 1: Methods for general application &#8211; Section Two: Thermal ageing methods&#8221; Clause 8.2 and 8.3<br \/>\nIEC 60335-1 (GB\/T 4706.1) &#8220;Household and similar electrical appliances &#8211; Safety &#8211; Part 1: General requirements&#8221; Clause 22.32<br \/>\nIEC 60245-1 (GB\/T 5013.1)&#8221;Rubber insulated cables &#8211; Rated voltages up to and including 450\/750 V &#8211; Part 1: General requirements&#8221;<\/p>\n<p><strong>Spesifikasi:<\/strong><\/p>\n<table style=\"width: 100.165%; height: 428px;\" width=\"315\">\n<tbody>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Power Supply Voltage<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">AC 220~240V 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Working Pressure<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">2.5 MPa<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Safety Burst Pressure<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">2.7~3.3 MPa<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Temperature Control Range<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">Room Temperature RT~200\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Chamber Dimensions<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">560*420*670 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Tank Dimensions<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">Diameter 123*Height 337 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Tank Volume<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">4000cm\u00b3<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Heater Power<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">2.4kW<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Temperature Alarm<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">0~200\u2103 (Adjustable)<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Temperature Deviation<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">\u00b10.5\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Kontrol Suhu<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">Digital display, intelligent control<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 34.2274%; text-align: center; vertical-align: middle;\" width=\"243\">Tank Material<\/td>\n<td style=\"width: 65.1288%; text-align: center; vertical-align: middle;\" width=\"72\">Stainless steel interior, electrostatic spray-coated cold-rolled steel exterior<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"attachment_15454\" style=\"width: 765px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" aria-describedby=\"caption-attachment-15454\" decoding=\"async\" class=\"wp-image-15454 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/10\/IEC-60335-1-Clause-22.32.png\" alt=\"\" width=\"755\" height=\"1006\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/10\/IEC-60335-1-Clause-22.32.png 755w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2024\/10\/IEC-60335-1-Clause-22.32-300x400.png 300w\" sizes=\"auto, (max-width: 755px) 100vw, 755px\" title=\"\"><\/p>\n<p id=\"caption-attachment-15454\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 60335-1 Clause 22.32<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The LS-B48 Oxygen Bomb Air Aging Test Chamber is designed and manufactured in full accordance with IEC 60811-401, IEC 60811-412, IEC 60811-1-2 Clause 8.2 and 8.3 (GB\/T 2951.12 Clause 8.2 and 8.3)\uff0cIEC 60335-1 Clause 22.32 (GB\/T 4706.1 Clause 22.32)\uff0cGB\/T 5013.1 and IEC 60245-1. It is suitable for aging experiments of medical device materials, wires and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3490,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[597],"class_list":["post-2903","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls-b48"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts\/2903","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/comments?post=2903"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/posts\/2903\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/media\/3490"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/media?parent=2903"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/categories?post=2903"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/id\/wp-json\/wp\/v2\/tags?post=2903"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}