The PHOTO-200 series Lux Meter | Brightness Meter | PPFD Meter | UV Irradiance Meter use high-precision linear optoelectronic sensor, which has the characteristics of lightweight, stable performance, high accuracy, high cost performance, and easy carrying. Widely used on-site lighting measurement, the research and development of light source products, quality monitoring of production lines, and plant factories.

Specifica:

Detector AccuracyClass A (± 4%reading ± 1 reading)
Reproducibility±0.5%
Display methodTouch screen (can expand: PC, mobile APP)
Screen Size1.54 “IPS HD LCD touch screen
Screen type180 degrees rotation
Communication methodUSB、Bluetooth
Charging interfaceType-C
Power supply1600mA lithium battery
Continuous work timeIt can be used continuously for 12 hours after one charge
Product Size65mm*60mm*60mm
Product weightAluminum alloy body, 100g
Secondary developmentSupport

Order Model:

Modello LISUNProduct NameTest Parameters and Specification
PHOTO-200Pocket Illuminance MeterIlluminance lux test range (380-780nm): 0.1-500,000lx (±0.1lx), upper and lower limit settings, sorting tests, optical change curves (PC software), illuminance, average illuminance, maximum illuminance, minimum illuminance, point illumination, illuminance transmission (%)
PHOTO-200LPocket Brightness MeterBrightness test range (380-780nm): 0.1-500,000cd/m² (±0.1cd/m²), upper and lower limit settings, sorting test, light change curve (PC software), brightness, average brightness, maximum brightness, minimum brightness, points brightness, brightness transmission (%)
PHOTO-200PPPFD Sensor and Lux MeterIlluminance lx, PPFD umol/m².s (400-700nm) test range: 0.1-500,000umol/m².s (±0.01umol/m².s) , Up and down limit settings, sorting tests, optical change curves (PC software), PPFD, average PPFD, maximum PPFD, minimum PPFD, energy, transmission ratio (%), testing time
PHOTO-200DLIPPFD Sensor(DLI)PPFD umol/m².s (400-700nm) test range: 0.1-500,000umol/m².s (±0.01umol/m².s), total amount of effective radiation umol/m².d
PHOTO-200BBlue Light Irradiance (460nm)Irradiance μW/cm² (peak: 460nm) test range: 0.1-200,000μW/cm² (±0.1μW/cm²), upper and lower limit settings, sorting tests, optical change curves (PC software), irradiation, average Irradiance degree, maximum Irradiance, minimum Irradiance degree, minimum Irradiance, degree Blu -ray energy μJ/cm², Irradiance transmission ratio (%), testing time
PHOTO-200UVUV IrradianceIrradiance μW/cm²(222 nm or 254nm or 365nm) test range: 0.1-500,000μW/cm² (±0.01μW/cm²), upper and lower limit settings, sorting tests, optical change curves (PC software), Irradiance degree, average Irradiance degree, maximum Irradiance, minimum Irradiance, UV energy, radiation transmission ratio (%), testing time
PHOTO-200UVZUV Irradiance (Multiband)Irradiance μW/cm²(254nm and 365nm) test range: 0.1-500,000μW/cm² (±0.01μW/cm²), upper and lower limit settings, sorting tests, optical change curve (PC software), radiation, average radiation, maximum radiation, minimum radiation, UV energy, radical transmission ratio (%), testing time
PHOTO-200RRed Light Irradiance (650nm)Irradiance μW/cm² (Peak: 650nm) test range: 0.1-200,000μW/cm² (±0.1μW/cm²), upper and lower limit settings, sorting tests, light change curve (PC software), irradiation, average radiation degree, maximum radiation, minimum radiation, red light energy μJ/cm², radiation transmission ratio (%), testing time
PHOTO-200IRnIR IrradianceIrradiance μW/cm² (850 nm or 940nm) test range: 0.1-500,000μW/cm² (±0.01μW/cm²)
PHOTO-200IRZnIR Irradiance (Multiband)Irradiance μW/cm² (850 nm and 940nm) test range: 0.1-500,000μW/cm² (±0.01μW/cm²)