Chat online

+8615317905991

Panoramica del tester di fiamma ad ago

Sommario

Introduzione alla prova di fiamma con ago

Needle flame testing is a critical flammability assessment method designed to evaluate the fire resistance of materials and components used in electrical, electronic, and industrial applications. The test simulates small ignition sources, such as electrical faults or overheating, to determine whether a material sustains combustion or self-extinguishes. Regulatory bodies, including IEC, UL, and GB/T, mandate needle flame testing to ensure product safety and compliance with international standards such as IEC 60695-11-5 E GB/T 5169.5-2020.

IL LISUN ZY-3 Needle Flame Tester is a precision-engineered instrument that adheres to these stringent testing protocols, providing manufacturers with reliable data to validate material performance under controlled flame exposure.

Principi e metodologia di test

IL test della fiamma dell'ago subjects a specimen to a defined flame source (typically a butane-fed needle flame) for a specified duration (e.g., 30 seconds). Post-ignition, the test evaluates:

  • Flame spread rate – Measures how quickly flames propagate across the material.
  • Afterflame and afterglow duration – Records the time the material continues burning or glowing after flame removal.
  • Comportamento di sgocciolamento – Assesses whether molten material drips and ignites underlying surfaces.

IL LISUN ZY-3 employs a calibrated 45° angle flame application, ensuring consistent heat flux (50W nominal output) and flame height (12±1mm). A digital timer and thermocouple system provide real-time monitoring, while an adjustable specimen holder accommodates varying material thicknesses and geometries.

Key Specifications of the LISUN ZY-3 Needle Flame Tester

ParametroSpecificazione
Flame Temperature1000°C ± 50°C
Flame Duration Control0–999.9s (adjustable)
Flame Height12 ± 1mm
Gas TypeButane (≥95% purity)
Test Angle45° fixed or adjustable
Standard di conformitàIEC 60695-11-5, GB/T 5169.5, UL 94 (supplementary)

Applicazioni industriali e requisiti di conformità

1. Apparecchiature elettriche ed elettroniche

Componenti come PCB substrates, connectors, and insulating materials must resist ignition from internal short circuits. The LISUN ZY-3 verifies compliance with IEC 62368-1, mitigating fire risks in power supplies and control systems.

2. Elettrodomestici

Heating elements, wiring harnesses, and plastic housings in appliances (e.g., microwaves, washing machines) undergo needle flame testing to meet IEC 60335-1 safety benchmarks.

3. Elettronica per autoveicoli

EV battery modules, infotainment systems, and wiring insulation are tested to ISO 20653 E SAE J1455, ensuring flame resistance in confined vehicular environments.

4. Apparecchi di illuminazione

LED drivers and luminaire housings must self-extinguish to comply with EN 60598-1. The ZY-3 assesses flame spread in polycarbonate and thermoplastic enclosures.

5. Medical Devices

Flammability testing of ventilator casings, surgical tool handles, and monitoring equipment adheres to ISO 14971 E IEC 60601-1, reducing fire hazards in oxygen-rich environments.

Vantaggi competitivi di LISUN ZY-3

  1. Precision Flame Control – Proprietary gas flow stabilization ensures ±2% flame consistency, critical for repeatable results.
  2. Automated Ignition and Cutoff – Reduces operator influence, enhancing reproducibility per ISO 17025 lab requirements.
  3. Multi-Standard Compatibility – Configurable settings support IEC, GB/T e UL test protocols without hardware modifications.
  4. Enhanced Safety Features – Flame arrestors, exhaust extraction, and emergency stop functions mitigate lab hazards.

Case Study: Evaluating Thermoplastic Enclosures for Industrial Controls

A manufacturer of PLC enclosures tested 30% glass-filled nylon samples using the LISUN ZY-3. Results demonstrated:

  • Afterflame time: ≤2s (meeting IEC 60695-11-5 Class V-0)
  • No dripping – Critical for overhead installations in factory automation.

Sezione FAQ

Q1: What is the difference between needle flame and glow-wire testing?
A1: Needle flame testing evaluates direct flame ignition (simulating electrical faults), while glow-wire testing assesses resistance to heat from high-current components (per Norma IEC 60695-2-10).

Q2: Can the ZY-3 test vertically oriented specimens?
A2: Yes, the specimen holder allows 0–90° adjustments, accommodating both horizontal and vertical test orientations per UL 94 protocols.

Q3: How often should the flame calibration be verified?
A3: Daily checks are recommended for high-throughput labs, with full recalibration every 6 months (per ISO 17025 guidelines).

Q4: Does the ZY-3 support non-standard specimen sizes?
A4: Custom fixtures can be integrated for irregular geometries (e.g., cable conduits or multi-layer composites).

Q5: What safety certifications does the ZY-3 hold?
A5: The system is CE-marked and complies with EN 61010-1 for electrical safety in test equipment.

Integrando il LISUN ZY-3 Needle Flame Tester into material qualification workflows, manufacturers ensure compliance with global flammability standards while mitigating fire risks across diverse industries.

Lasciate un messaggio

=
it_ITIT