Chat online

+8615317905991

Apparecchiatura di prova della fiamma ad ago: Garantire la conformità alla sicurezza antincendio

Sommario

Introduction to Needle Flame Testing

IL Test di fiamma con ago is a critical evaluation method for assessing the flammability of materials and components used in electrical and electronic equipment, automotive systems, and other high-risk applications. This test simulates small ignition sources, such as electrical faults or overheated components, to determine whether a material will ignite, sustain combustion, or propagate flames. Compliance with international standards—such as IEC 60695-11-5, GB/T 5169.5, and UL 746A—is mandatory for manufacturers seeking to validate product safety.

IL LISUN Apparecchio di prova della fiamma ad ago ZY-3 is a precision-engineered instrument designed to meet these stringent requirements. Its advanced control mechanisms, repeatable testing conditions, and compliance with multiple regulatory frameworks make it indispensable for industries where fire hazards pose significant risks.

Technical Principles of Needle Flame Testing

The test involves exposing a specimen to a controlled flame from a butane-fed needle burner for a predetermined duration (typically 30 seconds). Key parameters evaluated include:

  • Tempo di accensione: The duration before the material catches fire.
  • Flame Spread Rate: The speed at which flames propagate.
  • Self-Extinguishing Properties: Whether the material ceases burning after flame removal.
  • Comportamento di sgocciolamento: Whether molten droplets ignite secondary fires.

IL LISUN ZY-3 ensures precise flame application (50W nominal power, 12±1mm flame height) while maintaining consistent gas flow (99% purity butane). Its automated timing and positioning systems minimize operator influence, enhancing reproducibility.

Key Specifications of the LISUN ZY-3 Needle Flame Test Apparatus

ParametroSpecificazione
Flame Temperature≥ 1000°C
Flame Height Adjustment12 ± 1 mm
Durata del test0–999.9s (adjustable)
Gas SupplyButane (≥99% purity)
Standard di conformitàIEC 60695-11-5, GB/T 5169.5, UL 746A
Dimensioni800 × 600 × 1200 mm
Alimentazione220V, 50Hz

Applicazioni industriali e requisiti di conformità

1. Electrical and Electronic Equipment

Components such as circuit boards, connectors, and insulating materials must resist ignition from localized heat sources. The LISUN ZY-3 verifies compliance with IEC 60695-11-5, ensuring that short circuits or overheating do not lead to catastrophic failures.

2. Automotive Electronics

With increasing electrification, automotive wiring harnesses, control modules, and battery enclosures require rigorous flammability testing. The test della fiamma dell'ago assesses whether materials meet ISO 3795 and FMVSS 302 standards.

3. Household Appliances

Switches, thermostats, and motor housings in appliances must self-extinguish to prevent household fires. The ZY-3 provides quantifiable data for UL 94 and IEC 60335-1 certifications.

4. Medical Devices

Polymer casings for diagnostic equipment and surgical tools must not sustain combustion. The test ensures adherence to ISO 10993-1 and IEC 60601-1.

5. Aerospace and Aviation Components

Cabin interiors, wiring systems, and avionics enclosures undergo flame resistance validation per FAA and EN 45545-2. The ZY-3’s precision is critical for materials exposed to high-altitude conditions.

Vantaggi competitivi di LISUN ZY-3

  1. Automated Flame Positioning – Eliminates manual errors with servo-controlled burner alignment.
  2. Multi-Standard Compatibility – Configurable settings for IEC, UL, GB, and ISO requirements.
  3. Enhanced Safety Features – Flame arrestors, exhaust ventilation, and emergency shutoff mechanisms.
  4. Data Logging and Reporting – Integrated software generates compliance documentation for audits.
  5. Durability and Calibration Stability – Robust construction minimizes drift, ensuring long-term accuracy.

Case Study: Evaluating Cable Insulation for Telecommunications

A leading telecom manufacturer used the LISUN ZY-3 to test polyethylene-insulated cables under IEC 60332-1-2. Results demonstrated that flame spread was contained within 150mm, meeting Category A fire performance. The test identified a substandard batch with excessive dripping, prompting material reformulation.

Conclusione

IL LISUN ZY-3 Needle Flame Test Apparatus is an essential tool for manufacturers prioritizing fire safety in high-risk sectors. Its precision, compliance versatility, and reliability make it a benchmark for flammability testing across industries. By integrating this system into quality assurance protocols, organizations mitigate fire hazards and ensure adherence to global safety standards.

Sezione FAQ

Q1: What is the purpose of the needle flame test?
The test evaluates material resistance to small ignition sources, simulating faults like electrical arcing or overheating to ensure components do not propagate fires.

Q2: How does the LISUN ZY-3 improve testing accuracy?
Automated flame positioning, calibrated gas flow, and digital timing reduce human error, ensuring repeatable and compliant results.

Q3: Which industries require needle flame testing?
Electrical components, automotive electronics, medical devices, aerospace, and consumer electronics all mandate flammability validation under standards like IEC 60695-11-5.

Q4: Can the ZY-3 test materials with irregular shapes?
Yes, adjustable specimen holders accommodate varied geometries, including wires, connectors, and molded plastics.

Q5: What maintenance is required for the ZY-3?
Routine calibration checks, burner cleaning, and gas purity verification ensure consistent performance. Annual servicing by certified technicians is recommended.

Lasciate un messaggio

=