{"id":2326,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/high-precision-rotation-luminaire-goniospectroradiometer\/"},"modified":"2025-07-03T15:08:21","modified_gmt":"2025-07-03T07:08:21","slug":"high-precision-rotation-luminaire-goniospectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/it\/prodotti\/high-precision-rotation-luminaire-goniospectroradiometer\/","title":{"rendered":"Goniospettroradiometro ad alta precisione per apparecchi a rotazione"},"content":{"rendered":"<p>LSG-1890BCCD\/LSG-1800ACCD goniospectroradiometer is a high precision automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source. The LSG-1890BCCD\/LSG-1800ACCD can do the spatial CCT test and the light intensity distribution test. It is for industrial laboratory photometric data measurement of luminaires such as LED luminaires, LED Plant Lighting, HID luminaires, fluorescent lamps and so on.<\/p>\n<div id=\"attachment_6269\" class=\"wp-caption aligncenter\" style=\"width: 1930px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-6269 size-large\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LSG-1890BCCD_YK4-1-1920x618.jpg\" sizes=\"(max-width: 1920px) 100vw, 1920px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LSG-1890BCCD_YK4-1-1920x618.jpg 1920w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LSG-1890BCCD_YK4-1-400x129.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/LSG-1890BCCD_YK4-1-768x247.jpg 768w\" alt=\"High Precision Rotation Luminaire Goniophotometer LSG 1890B YK64\" width=\"1920\" height=\"618\" aria-describedby=\"caption-attachment-6269\" title=\"\"><\/p>\n<p id=\"caption-attachment-6269\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Goniospettroradiometro ad alta precisione ad apparecchio rotante<\/span><\/p>\n<\/div>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a>\u00a0\"Misure ottiche ed elettriche di prodotti per l'illuminazione a stato solido\".<br \/>\n<a href=\"https:\/\/www.lisungroup.cn\/wp-content\/uploads\/2019\/07\/EN13032-1-2004AC-2005.pdf\" target=\"_blank\" rel=\"noopener\">EN13032-1<\/a>\u00a0\"Luce e illuminazione - Misura e presentazione dei dati fotometrici di lampade e apparecchi di illuminazione - Parte 1: Misurazione e formato del file; versione tedesca EN 13032-1:2004+A1:2012\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a>\u00a0\"Misurazione della manutenzione dei lumen delle sorgenti luminose a LED\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CIE-121-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-121<\/a>\u00a0\" Fotometria e goniofotometria degli apparecchi di illuminazione\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-70-1987-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-70 \u201c<\/a>\u00a0The Measurement of Absolute Luminous Intensity Distribution\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESNA_LM-75-2001-Goniophotometer-Types-and-Photometric-Coordinates.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-75<\/a>\u00a0 \u201cGoniophotometerTypes and Photometric Coordinates\u201d<\/p>\n<p><strong>Misura:<br \/>\n<\/strong>Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution(Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, CCT, CRI, Color Temperature Distribution, Spectrum, (x, y)\/(u, v), PAR, PPF, PPFD 3D distribution test and etc.<\/p>\n<p><strong>Specifica:<\/strong><br \/>\n\u2022 LSG-1890BCCD\/LSG-1800ACCD Goniospectroradiometer=<a href=\"https:\/\/www.lisungroup.com\/products\/goniophotometer\/high-precision-rotation-luminaire-goniophotometer.html\" target=\"_blank\" rel=\"noopener noreferrer\">LSG-1890B\/LSG-1800A Goniophotometer System<\/a>\u00a0+\u00a0<a href=\"https:\/\/www.lisungroup.com\/products\/led-test-instruments\/high-precision-spectroradiometer-integrating-sphere-system.html\" target=\"_blank\" rel=\"noopener noreferrer\">Sistema di spettroradiometro a sfera integrato LPCE-2<\/a><br \/>\n\u2022 The goniophotometer can do the B-\u03b2 test with two pillars and the C-\u03b3 test with single pillar &amp; multi-function jigs<br \/>\n\u2022 Test Max Luminaires size and weight: LSG-1890BCCD is 2000mm\/60kg and LSG-1800ACCD is 1600mm\/50kg<br \/>\n\u2022 The tested luminaries rotates around an angle of (\u03b3)\u00b1180\u00b0(or 0-360\u00b0) and the tested luminaries rotates around itself with an angle of (C)\u00b1180\u00b0(or 0-360\u00b0)<br \/>\n\u2022 Angle accuracy: LSG-1890BCCD is 0.1\u00b0, LSG-1800ACCD is 0.2\u00b0<br \/>\n\u2022 Work with high accuracy and quick CCD Spectroradiometer to measure spatial color parameters<br \/>\n\u2022 Accuracy of chromaticity coordinate: \u00b10.0015 or \u00b10.0005(under standard A lamp)<br \/>\n\u2022 Spectral Range Wavelength: 350nm ~800nm; Accuracy of wavelength: \u00b10.5nm<br \/>\n\u2022 The Hardware and Software can do the PAR, PPF and PPFD 3D distribution test, which can export IES\/LDT files<br \/>\n\u2022 Photometry Accuracy: <a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/photo-detector.html\" target=\"_blank\" rel=\"noopener\">CIE Class A (Class L is option)<\/a><br \/>\n\u2022 Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%<br \/>\n\u2022 English version software can run in Win7, Win8, Win10, Win11<br \/>\n\u2022 LISUN <a href=\"https:\/\/www.lisungroup.com\/products\/goniophotometer\/\" target=\"_blank\" rel=\"noopener\">goniofotometro<\/a> software can export CIE, IES, LDT and other format files. These kinds of format files can be transferred by other illumination and luminaire design software such as DiaLux<\/p>\n<table style=\"width: 100.336%; height: 96px;\" border=\"1\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 19.9732%; height: 48px; vertical-align: middle;\">Modello LISUN<\/td>\n<td style=\"width: 58.9458%; height: 24px; vertical-align: middle;\">The Max Size for the Luminaires under Test (Diameter*Depth)<\/td>\n<td style=\"width: 41.8647%; height: 48px; vertical-align: middle;\">Max Weight<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 19.9732%; height: 24px; vertical-align: middle;\">LSG-1890BCCD<\/td>\n<td style=\"width: 58.9458%; height: 24px; vertical-align: middle;\">\u03a6 2000*600mm<\/td>\n<td style=\"width: 41.8647%; height: 24px; vertical-align: middle;\">60Kg<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 19.9732%; height: 24px; vertical-align: middle;\">LSG-1800ACCD<\/td>\n<td style=\"width: 58.9458%; height: 24px; vertical-align: middle;\">\u03a6 1600*600mm<\/td>\n<td style=\"width: 41.8647%; height: 24px; vertical-align: middle;\">50Kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Note:\u00a0 The LSG-1890BCCD is an update version of LSG-1800BCCD and LSG-1800XCCD. The LSG-1800ACCD is an update version of LSG-1700BCCD and LSG-1800CCD.<\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lsg-1890bccd-high-precision-rotation-luminaire-goniospectroradiometer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LSG-1890BCCD High Precision Rotation Luminaire Goniospectroradiometer \u2013 After-sales Frequently Asked Questions (FAQ).<\/span><\/a><br \/>\n<\/strong>LISUN LSG-1890BCCD High Precision Roation Luminaire Goniospectroradiometer were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>LSG-1890BCCD\/LSG-1800ACCD goniospectroradiometer is a high precision automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source. The LSG-1890BCCD\/LSG-1800ACCD can do the spatial CCT test and the light intensity distribution test. It is for industrial laboratory photometric data measurement of luminaires such as LED luminaires, LED Plant Lighting, HID luminaires, fluorescent [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4769,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[83],"class_list":["post-2326","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lsg-1890bccd"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2326","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/comments?post=2326"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2326\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media\/4769"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media?parent=2326"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/categories?post=2326"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/tags?post=2326"}],"curies":[{"name":"parola chiave","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}