{"id":2329,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/emi-test-receiver-2\/"},"modified":"2025-07-03T14:46:32","modified_gmt":"2025-07-03T06:46:32","slug":"emi-test-receiver-2","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/it\/prodotti\/emi-test-receiver-2\/","title":{"rendered":"EN55015 EN55022 Sistema di test delle molestie condotte EMI"},"content":{"rendered":"<p>EMI receiver system is for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is made of full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the <a href=\"https:\/\/www.lisungroup.com\/products\/emi-and-emc-test-system\/emi-test-receiver.html\" target=\"_blank\" rel=\"noopener\">EMI Test System<\/a>, it solved the instrument self-EMI problem. The test results are according to the international format test report.<\/p>\n<p><strong>Standard: standard<\/strong><br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CISPR15-2018-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CISPR15:2018\/ <\/a><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-17743-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB17743<\/a> \u201cLimits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CISPR16-1-AMD.2-F2-ED.1.0-1999-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CISPR16-1<\/a> \u201cSpecification for radio disturbance and immunity measuring apparatus and methods \u2013 Part 1-1: Radio disturbance and immunity measuring apparatus \u2013 Measuring apparatus\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/EN55015-2000-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">EN55015<\/a> \u201cLimits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment.\u201d<br \/>\nEN55022 \u201cRadio disturbance characteristics \u2013 Limits and methods of measurement\u201d<\/p>\n<p><strong>Configurazione del sistema:<br \/>\n<\/strong>\u2022 EMI-9KC Test System includes: EMI-9KC EMI Receiver built-in Attenuator (9K-1GHz), LISN Artificial Network Power, CDNE-M316 Coupling\/Decoupling Network for Emission, Isolation Transformers and cables.<br \/>\n\u2022 EMI-9KB Test System includes: EMI-9KB EMI Receiver (9K-300MHz), LISN Artificial Network Power, CDNE-M316 Coupling\/Decoupling Network for Emission, Isolation Transformers, Attenuator and cables.<br \/>\n\u2022 EMI-9KA Test System includes: EMI-9KA EMI Receiver (9K-30MHz), LISN Artificial Network Power, Isolation Transformers, Attenuator and cables.<\/p>\n<p><strong>Optional instruments to work with the EMI-9KC, EMI-9KB and EMI-9KA EMI receivers:<br \/>\n<\/strong>- <a href=\"http:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/ac-power-source.html\" target=\"_blank\" rel=\"noopener\">LISUN LSP-500VARC\/LSP-1KVARC Pure Sine Wave AC Power Source<\/a> per l'EUT<br \/>\n- <a href=\"http:\/\/www.lisungroup.com\/products\/emi-and-emc-test-system\/magnetic-shielding-cabinet-for-emi-testing.html\" target=\"_blank\" rel=\"noopener\">LISUN SDR-2000B Magnetic Shielding Cabinet<\/a> for the EMI Receiver System<br \/>\n- <a href=\"https:\/\/www.lisungroup.com\/products\/emi-and-emc-test-system\/three-loop-antenna.html\" target=\"_blank\" rel=\"noopener\">LISUN VVLA-30M Three Loop Antenna<\/a> to test 9k-30MHz radiation<br \/>\n- <a href=\"https:\/\/www.lisungroup.com\/products\/emi-and-emc-test-system\/absorbing-clamp.html\" target=\"_blank\" rel=\"noopener\">LISUN AB-CLP Absorbing Clamp<\/a> to test the home applications &amp; motor tools<br \/>\n- <a href=\"https:\/\/www.lisungroup.com\/products\/emi-and-emc-test-system\/radio-frequency-current-probe.html\" target=\"_blank\" rel=\"noopener\">LISUN VOL-CP RF Current Probe<\/a> to the conducted disturbance voltage<\/p>\n<p><strong>Specifica:<\/strong><br \/>\n\u2022 Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA)<br \/>\n\u2022 Frequency stability: 1\u00d710^<sup>-6<\/sup><br \/>\n\u2022 Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz<br \/>\n\u2022 Test Tolerance: \u00b12 dB<br \/>\n\u2022 Measure and Detection method: PK, QP and AV<br \/>\n\u2022 Measure range: 20dB\u03bcV~140dB\u03bcV<br \/>\n\u2022 Frequency scanning step frequency: 20Hz~2MHz<br \/>\n\u2022 Sweep bandwidth: 200Hz; 9kHz; 120kHz<br \/>\n\u2022 Connect PC via USB cable and software can run on Win7, Win8, Win10, Win11<\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/what-is-emi-receiver.html\" target=\"_blank\" rel=\"noopener\">What is EMI ?<\/a><\/strong><br \/>\nEMI (Electromagnetic Interference) is electronic noise that interferes with cable signals and reduces signal integrity. EMI is usually generated by electromagnetic radiation sources such as motors and machines. Electromagnetic Interference has two types: conducted interference and radiated interference. Conducted interference refers to the coupling (interference) of signals on one electrical network to another electrical network through a conductive medium. Radiated interference refers to the interference source coupling (interference) its signal to another electrical network through space.<\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/how-to-test-emi-interference.html\" target=\"_blank\" rel=\"noopener\">How to test Electromagnetic Interference?<\/a><\/strong><br \/>\nElectromagnetic disturbance that degrades the performance of electrical equipment or electronic device, works abnormally or fails. It can be divided into conducted interference test and radiated interference test. LISUN EMI-9KB is an automatic EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. It can do both conducted interference test and radiated interference test.<\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/the-difference-between-emi-and-ems.html\" target=\"_blank\" rel=\"noopener\">What\u2019s the difference between EMI and EMS?<\/a><\/strong><br \/>\nEMC (Electro\u2002Magnetic\u2002Compatibility) literally translates to \u201celectromagnetic compatibility\u201d. EMI (Electromagnetic\u2002Interference) can be understood as attack type. There are two types of EMI, conducted interference and radiated interference. EMS (Electro\u2002Magnetic\u2002Susceptibility) literally translates to \u201celectromagnetic sensitivity\u201d, which we can understand as defensive type, which means the ease of performance degradation due to electromagnetic energy.<\/p>\n<p>Noted: According to latest <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CISPR15-2013-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CISPR15:2018<\/a> standard, you need to use CDNE-M316 (Coupling\/Decoupling Network for Emission) instead the CDN. The CDNE-M316 working with EMI receiver system is equivalent to test radiated electromagnetic disturbance of electric lighting appliance with frequency from 30M to 300mHz.<\/p>\n<div id=\"attachment_4491\" class=\"wp-caption aligncenter\" style=\"width: 410px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-4491\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CDNE-M316_AL1-2-400x400.jpg\" sizes=\"(max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CDNE-M316_AL1-2-400x400.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CDNE-M316_AL1-2-100x100.jpg 100w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CDNE-M316_AL1-2-768x768.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CDNE-M316_AL1-2-1080x1080.jpg 1080w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CDNE-M316_AL1-2.jpg 1200w\" alt=\"\" width=\"400\" height=\"400\" aria-describedby=\"caption-attachment-4491\" title=\"\"><\/p>\n<p id=\"caption-attachment-4491\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">CDNE-M316 Coupling\/Decoupling Network for Emission<\/span><\/p>\n<\/div>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-emi-receiver-emi-9kb-or-emi-9ka-after-sales-questions-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN EMI Test Receiver EMI-9KC\/EMI-9KB\/EMI-9KA \u2013 After-sales Frequently Asked Questions (FAQ)<\/span><\/a><br \/>\n<\/strong>LISUN EMI Test Receiver EMI-9KB or EMI-9KA were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>EMI receiver system is for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is made of full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3222,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[37],"class_list":["post-2329","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-emi-9kb"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2329","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/comments?post=2329"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2329\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media\/3222"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media?parent=2329"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/categories?post=2329"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/tags?post=2329"}],"curies":[{"name":"parola chiave","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}