{"id":2345,"date":"2025-06-19T19:35:01","date_gmt":"2025-06-19T11:35:01","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/adjustable-high-frequency-reference-ballast\/"},"modified":"2025-06-27T14:43:57","modified_gmt":"2025-06-27T06:43:57","slug":"adjustable-high-frequency-reference-ballast","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/it\/prodotti\/adjustable-high-frequency-reference-ballast\/","title":{"rendered":"Ballast di riferimento ad alta frequenza regolabile"},"content":{"rendered":"<p>HCS-109A Adjustable High Frequency Reference Ballast is also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with LPCE-2 <a href=\"https:\/\/www.lisungroup.com\/products\/led-test-instruments\/high-precision-spectroradiometer-integrating-sphere-system.html\" target=\"_blank\" rel=\"noopener\">high precision spectroradiometer integrating sphere system<\/a> can also measure the photometric, colorimetric and electrical parameters for high frequency fluorescent lamp.<\/p>\n<p><strong>Standard: standard<br \/>\n<\/strong><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60081-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60081:<\/a>1997\/ GB\/T 10682-2002 \u201cDouble-capped fluorescent lamps \u2013 Performance specifications \u201c<br \/>\nUL1993 \u201d Safety for Self-Ballasted Lamps and lamp Adapters\u201d<\/p>\n<p><strong>Applicazione:<\/strong><br \/>\n\u2022 According to UL1993,\u00a0HCS-109A is used to do input test, temperature rise test, leakage current test and harmonic distortion test for LED Type A tube direct replacement fluorescent tube.<br \/>\n\u2022 According to GB\/T 10682-2002, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/UL1993-S-2012-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">UL1993-S<\/a> E <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60081-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60081<\/a>:1997, HCS-109A is used to test the high frequency fluorescent lamp such as T5 tube and power frequency fluorescent lamp such as T8\/T12 tube. Please visit this page to learn more about <a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/how-to-measure-the-high-frequency-fluorescent-lamp.html\" target=\"_blank\" rel=\"noopener\">How to Measure the High Frequency Fluorescent Lamp<\/a>.<\/p>\n<p><strong>Specifica:<br \/>\n<\/strong>\u2022 Input voltage: 200V~240V, 50\/60Hz<br \/>\n\u2022 Input Power: 80 W max<br \/>\n\u2022 Output Current: 130mA~400mA\u00a0(Adjustable), accuracy:\u00a0+\/- 1%<br \/>\n\u2022 Output Frequency: 25kHz&lt; +\/-2.0% (Adjustable), accuracy:\u00a0+\/- 0.3kHz<br \/>\n\u2022 Output current total harmonic wave distortion: THD&lt;2.5% (HF current wave)<\/p>\n<p><strong>Test connection one:<\/strong><br \/>\nIt can be connect with LISUN\u2019s <a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-power-meter-high-accuracy-model.html\" target=\"_blank\" rel=\"noopener\">LS2050 High Accuracy Digital Power Meter<\/a> E <a href=\"https:\/\/www.lisungroup.com\/products\/electrical-safety-tester\/digital-oscilloscope.html\" target=\"_blank\" rel=\"noopener\">Oscilloscopio digitale OSP1102<\/a>.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-5903 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HCS-109A_3.jpg\" sizes=\"(max-width: 4584px) 100vw, 4584px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HCS-109A_3.jpg 4584w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HCS-109A_3-400x110.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HCS-109A_3-768x212.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HCS-109A_3-1920x529.jpg 1920w\" alt=\"\" width=\"4584\" height=\"1263\" title=\"\"><\/p>\n<p><strong style=\"font-size: 16px;\">Test connection Two:<br \/>\n<\/strong>It can connect with LISUN\u2019s <a href=\"https:\/\/www.lisungroup.com\/products\/electronic-ballast-tester\/electronic-ballast-tester.html\" target=\"_blank\" rel=\"noopener\">WT5000 Electronic Ballast Tester<\/a> E <a href=\"https:\/\/www.lisungroup.com\/products\/electrical-safety-tester\/digital-oscilloscope.html\" target=\"_blank\" rel=\"noopener\">Oscilloscopio digitale OSP1102<\/a>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-5904 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HCS-109A_4.jpg\" sizes=\"(max-width: 5000px) 100vw, 5000px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HCS-109A_4.jpg 5000w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HCS-109A_4-400x106.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HCS-109A_4-768x203.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/HCS-109A_4-1920x508.jpg 1920w\" alt=\"\" width=\"5000\" height=\"1322\" title=\"\"><\/p>\n<div class=\"saswp-g-review-panel\">\n<div class=\"saswp-glg-review-body\">\n<div class=\"saswp-rv-cnt\">\n<div class=\"saswp-rv-txt\">\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>HCS-109A Adjustable High Frequency Reference Ballast is also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with LPCE-2 high precision spectroradiometer integrating sphere system can also measure the photometric, colorimetric and electrical parameters for high frequency fluorescent lamp. Standard\uff1a IEC 60081:1997\/ [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3350,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[103],"class_list":["post-2345","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-hcs-109a"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2345","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/comments?post=2345"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2345\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media\/3350"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media?parent=2345"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/categories?post=2345"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/tags?post=2345"}],"curies":[{"name":"parola chiave","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}