{"id":2359,"date":"2025-06-19T19:35:01","date_gmt":"2025-06-19T11:35:01","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/high-current-arc-ignition-test-system\/"},"modified":"2025-07-03T15:05:15","modified_gmt":"2025-07-03T07:05:15","slug":"high-current-arc-ignition-test-system","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/it\/prodotti\/high-current-arc-ignition-test-system\/","title":{"rendered":"High Arc Current Ignition Testing"},"content":{"rendered":"<p>HCAI-2 Large Arc Ignition Test System is according to IEC 61800-5-1:2022 Clause 5.2.5.2 Figure 26,\u00a0 IEC 60947-1:2020 Annex M Figure M.2 (GB\/T 14048.1-2023 Appendix M Figure M.2), IEC 60730:2022 Annex D.1.10( GB 14536.1-2022 Appendix D.1.10), IEC 60950-1:2020 ( GB 4943.1-2022) ,\u00a0 BS 7002:2000, and UL 746A:2021. <span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">It is mainly used in the parts of insulating materials or other solid combustible materials that are easy to spread flames inside electrical and electronic equipment. They may ignite due to proximity or contact with electric arcs, causing electrical fires and endangering the reliable operation of equipment and personal safety.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">This test system is suitable for the research, production and quality inspection departments of electrical and electronic products and their components such as lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motors, power tools, electronic instruments, electrical instruments, information technology equipment, electrical business equipment, electrical connectors and accessories, and is also suitable for the insulation material, engineering plastics or other solid combustible material industries.<\/span><\/span><\/span><\/p>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IEC60950-1.pdf\" target=\"_blank\" rel=\"noopener\">IEC 60950-1:2020<\/a> \u201cInformation technology equipment \u2013 Safety \u2013 Part 1: General requirements\u201d<br \/>\nBS EN 60950-1:2020 \u201cInformation technology equipment \u2013 Safety \u2013 Part 1: General requirements\u201d<br \/>\nBS 7002:2000 \u201cSpecification for Safety of Information Technology Equipment Including Electrical Business Equipment\u201d<br \/>\nUL 746A:2021 \u201cUL Standard for Safety Polymeric Materials \u2013 Short Term Property Evaluations\u201d<br \/>\nIEC 60947.1: 2020 \u201cLow-voltage switchgear and controlgear \u2013 Part 1: General rules\u201d<br \/>\nIEC 730.1:1993<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-4943-2001-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB 4943.1-2022 \u201cSafety of Information Technology Equipment\u201d<\/a><br \/>\nIEC 60664-1:2020 \u201cInsulation coordination for equipment within low-voltage supply systems \u2013 Part 1: Principles, requirements and tests\u201d<\/p>\n<p><strong>Test principle:<\/strong><br \/>\nThe arc ignition is repeated on the surface of the sample to 200 times, and the high current arc ignition resistance performance of the sample is evaluated by whether the sample ignites under the specified number of arc ignition.<\/p>\n<p><strong>Configurazione del sistema:<\/strong><br \/>\n\u2022 Screen: 7-inch touch screen.<br \/>\n\u2022 Control System: PLC.<br \/>\n\u2022 40A Power Meter: Real-time display of current, voltage, power, frequency, power factor, and with alarm function.<br \/>\n\u2022 Test voltage, current and power factor are adjustable.<br \/>\n\u2022 Equipped with a fan exhaust system, built-in LED lighting, and all electrical parts adopt world-renowned brands such as Schneider.<\/p>\n<p><strong>Specifica:<\/strong><br \/>\n\u2022 Electrode materials: copper (electrostatic electrode), stainless steel (movable electrode);<br \/>\n\u2022 Electrode size: \u04443.2mm\uff5e\u04443.5mm 30\u00b0 chisel end (static electrode), \u04443.0mm 60\u00b0 cone end (moving electrode);<br \/>\n\u2022 Electrode angle: 45\u00b0 from the horizontal plane;<br \/>\n\u2022 Arcing current: 33\u00b15%A (Adjustable);<br \/>\n\u2022 Arcing power factor: COS\u03c60.5\u00b10.05 (Adjustable);<br \/>\n\u2022 Arcing speed: 250mm\/s \u00b1 25mm\/s;<br \/>\n\u2022 Arc ignition frequency: 40 times\/min (Adjustable);<br \/>\n\u2022 Number of arcs: 200 times (Can preset);<br \/>\n\u2022 Sample size: 130mm*13mm*(2~12)mm;<br \/>\n\u2022 Power Supply: 220V\/10kVA\/50Hz<\/p>\n<p><strong>Operation:<br \/>\n<\/strong><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Set the test times, test speed, and loading current on the touch screen. Click \u201cStart Test\u201d after adjusting the power factor to 0.5. The test will be automatically performed according to the set requirements. After the test is completed, the test power will be automatically cut off and a buzzer alarm will sound.<\/span><\/span><\/span><\/p>\n<div id=\"attachment_14929\" class=\"wp-caption aligncenter\" style=\"width: 728px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-14929 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720240710180226.jpg\" sizes=\"(max-width: 718px) 100vw, 718px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720240710180226.jpg 718w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/QQ\u56fe\u724720240710180226-400x385.jpg 400w\" alt=\"\" width=\"718\" height=\"691\" aria-describedby=\"caption-attachment-14929\" title=\"\"><\/p>\n<p id=\"caption-attachment-14929\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 61800-5-1:2022 Clause 5.2.5.2 Figure 26<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>HCAI-2 Large Arc Ignition Test System is according to IEC 61800-5-1:2022 Clause 5.2.5.2 Figure 26,\u00a0 IEC 60947-1:2020 Annex M Figure M.2 (GB\/T 14048.1-2023 Appendix M Figure M.2), IEC 60730:2022 Annex D.1.10( GB 14536.1-2022 Appendix D.1.10), IEC 60950-1:2020 ( GB 4943.1-2022) ,\u00a0 BS 7002:2000, and UL 746A:2021. It is mainly used in the parts of insulating [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3349,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[116],"class_list":["post-2359","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-hcai-2"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2359","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/comments?post=2359"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2359\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media\/3349"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media?parent=2359"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/categories?post=2359"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/tags?post=2359"}],"curies":[{"name":"parola chiave","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}