{"id":2402,"date":"2025-06-19T19:35:24","date_gmt":"2025-06-19T11:35:24","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/high-precision-ccd-spectroradiometer\/"},"modified":"2025-07-03T15:09:12","modified_gmt":"2025-07-03T07:09:12","slug":"high-precision-ccd-spectroradiometer","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/it\/prodotti\/high-precision-ccd-spectroradiometer\/","title":{"rendered":"High-accuracy\u00a0 Spectroradiometer"},"content":{"rendered":"<p>LMS-9000C High Precision CCD Spectroradiometer is according to LM-79 clause 9.1. It is designed for any visible optical spectrum distribution analysis, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED optical spectrum analyzer is used as a transfer standard for photometric, colorimetric a<a id=\"mcegrid16\" class=\"mce-active\" href=\"https:\/\/www.lisungroup.com\/wp-admin\/post.php?post=1962&amp;action=edit#\" data-mce-x=\"6\" data-mce-y=\"1\" target=\"_blank\" rel=\"noopener\"><\/a>nd radiometric applications.<\/p>\n<p>LMS-9000C can do quick test with high accuracy. It used in scientific lab. It works with <a href=\"https:\/\/www.lisungroup.com\/products\/integrating-sphere\/integrating-spheres.html\" target=\"_blank\" rel=\"noopener\">sfera integrante<\/a> and standard lamp as a system: <a href=\"https:\/\/www.lisungroup.com\/products\/led-test-instruments\/high-precision-spectroradiometer-integrating-sphere-system.html\" target=\"_blank\" rel=\"noopener\">LPCE-2 High Precision Spectroradiometer Integrating Sphere System<\/a>.<\/p>\n<p><strong>Standard<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-177-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE 177<\/a> \"Resa cromatica delle sorgenti luminose a LED bianchi\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-84-1989-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE84<\/a> \"La misurazione del flusso luminoso\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-13.3-1995-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-13.3<\/a> \"Metodo di misurazione e specificazione delle propriet\u00e0 di resa cromatica delle sorgenti luminose\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \"Misure ottiche ed elettriche di prodotti per l'illuminazione a stato solido\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IESNA-LM-63-2-2002-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IESNA LM-63-2<\/a> \"Formato di file standard IESNA per il trasferimento elettronico di dati fotometrici e informazioni correlate\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"Misurazione della manutenzione dei lumen delle sorgenti luminose a LED\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/ANSI-C78.377-2015-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">ANSI-C78.377<\/a> \"Specifiche per la cromaticit\u00e0 dei prodotti di illuminazione a stato solido per lampade elettriche\".<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2021\/06\/EU2019-2015.pdf\" target=\"_blank\" rel=\"noopener\">(UE) 2019\/2015<\/a> \"REGOLAMENTO DELEGATO DELLA COMMISSIONE\"<\/p>\n<p><strong>Misura:<br \/>\n<\/strong>- Colorimetrico: Coordinate cromatiche, CCT, rapporto cromatico, lunghezza d'onda di picco, larghezza di banda dimezzata, lunghezza d'onda dominante, purezza del colore, IRC, CQS, TM-30 (Rf, Rg), test dello spettro.<br \/>\n- Fotometria: Flusso luminoso, efficienza luminosa, potenza radiante, WPE, EQE, EEI, classe di efficienza energetica, flusso pupillare, efficienza del flusso pupillare, fattore pupillare, flusso cirtopico, PAR e PPF delle lampade per la crescita delle piante.<br \/>\n\u2022 Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic<br \/>\n\u2022 LED optical maintenance test: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time<\/p>\n<p><strong>Specifica:<\/strong><br \/>\n- Precisione della lunghezza d'onda spettrale: \u00b10,3nm, riproducibilit\u00e0 della lunghezza d'onda: \u00b10,1nm<br \/>\n- Passi di scansione del campione: \u00b10,1nm<br \/>\n- Precisione delle coordinate cromatiche (\u0394x, \u0394y): \u00b10,002 (con lampada standard A)<br \/>\n- Temperatura colore correlata CCT: 1.500K~100.000K, precisione CCT: \u00b10,3%<br \/>\n- Gamma dell'indice di resa cromatica: 0~100.0, Precisione: \u00b1(0.3%rd\u00b10.3)<br \/>\n- Gamma del flusso luminoso: 0,01-200.000lm; Precisione lineare fotometrica: \u00b10,5%<br \/>\n- Luce parassita: &lt;0,015% (600nm) e &lt;0,03% (435nm)<br \/>\n- Tempo di integrazione: 0,1 ~ 10.000 ms<br \/>\n- Pu\u00f2 misurare le temperature all'interno e all'esterno della sfera integrante.<br \/>\n\u2022 Total flux testing method: spectrum, photometric and spectrum with photometric revision<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 20%;\"><strong>Modello LISUN<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000C<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000CUV-VIS<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000CVIS-NIR<\/strong><\/td>\n<td style=\"width: 20%;\"><strong>LMS-9000CUV<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 20%;\"><strong>Lunghezza d'onda<\/strong><\/td>\n<td style=\"width: 20%;\">350-800nm<\/td>\n<td style=\"width: 20%;\">200-800nm<\/td>\n<td style=\"width: 20%;\">350-1050nm<\/td>\n<td style=\"width: 20%;\">200-400nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The LMS-9000C (which is updated on LMS-9000B) uses the band pass-filter wheel correcting technique, spectrometer &amp; broadband-radiometer &amp; photometer combined technique, and modified NIST stray light correction technology. The LMS-9000C spectroradiometer can realize ultra low stray light and super photometry linearity in overall dynamic range.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-3557 aligncenter\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/High-Precision-CCD-Spectroradiometer.jpg\" sizes=\"(max-width: 600px) 100vw, 600px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/High-Precision-CCD-Spectroradiometer.jpg 600w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/High-Precision-CCD-Spectroradiometer-400x193.jpg 400w\" alt=\"Spettroradiometro CCD ad alta precisione\" width=\"600\" height=\"289\" title=\"\"><\/p>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lpce-2lms-9000c-high-precision-spectroradiometer-integrating-sphere-system-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN LPCE-2(LMS-9000C) Spettroradiometro di alta precisione che integra il sistema a sfera - Domande frequenti post-vendita (FAQ).<\/span><\/a><br \/>\n<\/strong>LISUN LPCE-2 (LMS-9000C), spettroradiometro ad alta precisione che integra il sistema a sfera, \u00e8 sul mercato da pi\u00f9 di 10 anni. Il team di assistenza tecnica di LISUN ha gi\u00e0 riassunto la maggior parte delle domande e delle risposte post-vendita nel link qui sopra. Si prega di leggerlo attentamente, in modo da poter risolvere da soli la maggior parte dei problemi se si hanno delle domande durante l'utilizzo degli strumenti. LISUN continuer\u00e0 ad aggiornare queste pagine e altre FAQ possono essere trovate in questo link.<\/p>","protected":false},"excerpt":{"rendered":"<p>LMS-9000C High Precision CCD Spectroradiometer is according to LM-79 clause 9.1. It is designed for any visible optical spectrum distribution analysis, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED optical spectrum analyzer is used as a transfer standard for photometric, colorimetric and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3427,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[159],"class_list":["post-2402","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lms-9000c"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2402","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/comments?post=2402"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2402\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media\/3427"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media?parent=2402"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/categories?post=2402"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/tags?post=2402"}],"curies":[{"name":"parola chiave","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}