{"id":2425,"date":"2025-06-19T19:35:47","date_gmt":"2025-06-19T11:35:47","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/led-driver-automatic-test-system\/"},"modified":"2025-06-27T11:44:01","modified_gmt":"2025-06-27T03:44:01","slug":"led-driver-automatic-test-system","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/it\/prodotti\/led-driver-automatic-test-system\/","title":{"rendered":"Sistema di test automatico per driver LED"},"content":{"rendered":"<p>ATE-2 LED driver automatic test equipment is applied to the production line for the finished products testing. With features of simplified operation and nice-looking, the workers can operate it at very short time. This system can meet the requirements of <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC62384-2006-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC62384<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GBT-24825-2009-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB24825-2009<\/a> and other relative standards.<\/p>\n<p><strong>Standard:<\/strong><br \/>\nIEC 62384:2006\/<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/GB-T24825-2009-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">GB\/T 24825<\/a>-2009\u00a0 \u201cDC or AC supplied electronic control gear for LED modules \u2013 Performance requirements\u201d<br \/>\nIEC61000-3-2 \u201cLimits for harmonic current emission(equipment input current\u226616A per phase\u201d<\/p>\n<p><strong>Characteristics:<\/strong><br \/>\n\u2022 This system includes 2 groups (left and right); the 2 groups can work in turn, so that to improve the work efficiency. For example, if the left is on working, then the right can make wire connection.<br \/>\n\u2022 It can test 4 LED drivers input and output at one time.<br \/>\n\u2022 The equipment can connect with electronic load and LED load, the two difference loads can be fast switch under the control of computer.<br \/>\n\u2022 Enable to print out the series number and parameters of sub-quality products by working with a micro-printer,<br \/>\n\u2022 Enable to achieve the bar-code record function by working with a bar-code scanner.<br \/>\n\u2022 The test report can be saved as Excel file for consult, statistic and analysis purpose.<br \/>\n\u2022 Good software interface to freely choose the difference parameters combination, so that to meet different demands. All the parameters can set limit, and with the quality analysis function.<\/p>\n<p><strong>Specifiche:<\/strong><\/p>\n<table style=\"width: 100.592%; height: 576px;\" border=\"1\" width=\"1095\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 14.7424%; height: 24px; vertical-align: middle;\"><strong>Item<\/strong><\/td>\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\"><strong>Test Range<\/strong><\/td>\n<td style=\"width: 13.5165%; height: 24px; vertical-align: middle;\"><strong>Tolerance<\/strong><\/td>\n<td style=\"width: 18.2774%; height: 24px; vertical-align: middle;\"><strong>Test Condition<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 14.7424%; height: 48px; vertical-align: middle;\" rowspan=\"2\">Tensione<\/td>\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0AC: 3\uff5e300V (CF=1.67)<\/td>\n<td style=\"width: 13.5165%; height: 144px; vertical-align: middle;\" rowspan=\"6\">\u00a0\u00b1(0.1%reading+0.1%range+1digit)<\/td>\n<td style=\"width: 18.2774%; height: 264px; vertical-align: middle;\" rowspan=\"9\">45~65Hz sine-wave Calibration validity: 12 months<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0DC: 3\uff5e500V<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 14.7424%; height: 48px; vertical-align: middle;\" rowspan=\"2\">Attuale<\/td>\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0AC: 5mA\uff5e2.7A (CF=3)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0DC: 5mA\uff5e8A<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 14.7424%; height: 48px; vertical-align: middle;\" rowspan=\"2\">Potenza<\/td>\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0AC: 0.015\uff5e800W<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0DC: 0.015\uff5e4000W<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 14.7424%; height: 48px; vertical-align: middle;\">Power Factor<\/td>\n<td style=\"width: 22.6289%; height: 48px; vertical-align: middle;\">\u00a00.000\uff5e1.000<\/td>\n<td style=\"width: 13.5165%; height: 48px; vertical-align: middle;\">\u00a0\u00b1(0.002+0.001\/reading+1digit)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 14.7424%; height: 24px; vertical-align: middle;\">Frequenza<\/td>\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a045Hz\uff5e65Hz<\/td>\n<td style=\"width: 13.5165%; height: 24px; vertical-align: middle;\">\u00a0\u00b10.1% Reading<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 14.7424%; height: 48px; vertical-align: middle;\">Armonico<\/td>\n<td style=\"width: 22.6289%; height: 48px; vertical-align: middle;\">\u00a0Total harmonic and 2-11 times harmonic component<\/td>\n<td style=\"width: 13.5165%; height: 48px; vertical-align: middle;\">\u00a0\u00b1(0.1% range+5% Reading)<\/td>\n<\/tr>\n<tr style=\"height: 96px;\">\n<td style=\"width: 14.7424%; height: 96px; vertical-align: middle;\">Surge Current<\/td>\n<td style=\"width: 22.6289%; height: 96px; vertical-align: middle;\">\u00a050mA\uff5e100A<\/td>\n<td style=\"width: 13.5165%; height: 96px; vertical-align: middle;\">\u00a0\u00b1(0.5% range+0.5% range+1digit)<\/td>\n<td style=\"width: 18.2774%; height: 96px; vertical-align: middle;\">Square wave with pulse width greater than 10\u03bcs<br \/>\nCalibration validity: 12months<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 14.7424%; height: 48px; vertical-align: middle;\" rowspan=\"2\">Lamp Voltage<\/td>\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0AC: 3\uff5e300V (CF=1.67)<\/td>\n<td style=\"width: 13.5165%; height: 144px; vertical-align: middle;\" rowspan=\"6\">\u00a0\u00b1(0.1%reading+0.1%range+1digit)<\/td>\n<td style=\"width: 18.2774%; height: 144px; vertical-align: middle;\" rowspan=\"6\">45~65Hz sine-wave Calibration validity: 12moths<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0DC: 3\uff5e500V<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 14.7424%; height: 48px; vertical-align: middle;\" rowspan=\"2\">Lamp Current<\/td>\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0AC: 5mA~2.7A (CF=3)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0DC: 5mA\uff5e8A<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 14.7424%; height: 48px; vertical-align: middle;\" rowspan=\"2\">Lamp Power<\/td>\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0AC: 0.015\uff5e800W<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 22.6289%; height: 24px; vertical-align: middle;\">\u00a0DC: 0.015\uff5e4000W<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 14.7424%; height: 48px; vertical-align: middle;\">Ripple Current<\/td>\n<td style=\"width: 22.6289%; height: 48px; vertical-align: middle;\">\u00a0Max: 5mA\uff5e8A<\/td>\n<td style=\"width: 13.5165%; height: 48px; vertical-align: middle;\">\u00a0\u00b1(1%reading+1%range)<\/td>\n<td style=\"width: 18.2774%; height: 48px; vertical-align: middle;\">20-70kHz sine-wave<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>ATE-2 LED driver automatic test equipment is applied to the production line for the finished products testing. With features of simplified operation and nice-looking, the workers can operate it at very short time. This system can meet the requirements of IEC62384, GB24825-2009 and other relative standards. Standard: IEC 62384:2006\/GB\/T 24825-2009\u00a0 \u201cDC or AC supplied electronic [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3149,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[182],"class_list":["post-2425","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ate-2"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/comments?post=2425"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2425\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media\/3149"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media?parent=2425"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/categories?post=2425"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/tags?post=2425"}],"curies":[{"name":"parola chiave","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}