{"id":2983,"date":"2025-06-19T19:42:51","date_gmt":"2025-06-19T11:42:51","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/iec-62115-clause-19-radiation-and-similar-hazards-test-system-for-electric-toys\/"},"modified":"2025-07-01T13:24:29","modified_gmt":"2025-07-01T05:24:29","slug":"iec-62115-clause-19-radiation-and-similar-hazards-test-system-for-electric-toys","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/it\/prodotti\/iec-62115-clause-19-radiation-and-similar-hazards-test-system-for-electric-toys\/","title":{"rendered":"IEC 62115 Clause 19 Radiation and Similar Hazards Test System for Electric Toys"},"content":{"rendered":"<p>The LS-IEC62115C19 Radiation and Similar Hazards Test System for Electric Toys fully complies with Clause 19 of IEC 62115. This clause specifically regulates the photobiological safety performance of light sources in toys, aiming to prevent potential hazards such as photochemical and thermal damage to children\u2019s eyes and skin caused by light sources.<\/p>\n<p>Targeting the core requirements of Clause 19 of IEC 62115, the LS-IEC62115C19 Radiation and Similar Hazards Test System for Electric Toys establishes a professional detection system. It can accurately measure key parameters of various toy light-emitting devices, including radiation intensity, irradiance, photochromic expansion angle, peak wavelength, dominant wavelength, and bandwidth. By simulating the lighting scenarios when children normally use toys, it evaluates photobiological safety indicators such as the blue light hazard level of light sources and ultraviolet radiation intensity. Equipped with a high-precision spectral analysis module and an automatic control unit, the system can quickly capture changes in the photobiological characteristics of light sources under different operating conditions. For example, it can real-time monitor the spectral stability of light-emitting toys during continuous operation and the impact of the frequency and light intensity fluctuations of flickering light sources on children\u2019s vision.<\/p>\n<p>Relying on the strict implementation of Clause 19 of IEC 62115 through this testing system, toy manufacturers and testing institutions can scientifically determine whether toy light sources meet photobiological safety requirements, avoiding safety risks caused by light source design defects from the source, and building a technical defense line for the eye and skin safety of children when they come into contact with light-emitting toys.<\/p>\n<p><strong>Configurazione del sistema:<br \/>\n<\/strong><\/p>\n<table style=\"width: 100.38%; height: 603px;\" width=\"800\">\n<tbody>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\"><strong>No.\u00a0<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\"><strong>Nome del prodotto<\/strong><\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"356\"><strong>Remarks<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"800\"><strong>Part 1\uff1aRadiation and Similar Hazards Test System for Electric Toys<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">1.1<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Radiation and Similar Hazards Test System<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" rowspan=\"6\" width=\"356\">200~1700nm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">1.2<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Photobiological Visible Near Infrared Hazard Testing System<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">1.3<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Photobiological Near-infrared Hazard Testing System<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">1.4<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Flicker Test Module<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">1.5<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Photobiological Safety Test Analysis Software<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">1.6<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Industrial Computers and Monitors<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"800\"><strong>Part 2\uff1aOptical Test Bench System<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">2.1<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Programmable 2D Sample Rotation Stage<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"356\">Load the Object to be Measured<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">2.2<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">System Platform<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"356\">Automatic Probe Switching<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"800\"><strong>Part 3\uff1aStandard Light Source System<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">3.1<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">UV Irradiance Standard Source<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"356\">200~400nm Including NIM Calibrate Certificate<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">3.2<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Visible and Near-infrared Irradiance Standard Sources<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"356\">380~1700nm Including NIM Calibrate Certificate<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" colspan=\"3\" width=\"800\"><strong>Part 4\uff1aAC\/DC power supplies, power meters and cabinets<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">4.1<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Pure Sine Wave AC Power Source<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"356\"><a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/ac-power-source.html\" target=\"_blank\" rel=\"noopener\">LSP-500VARC<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">4.2<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Digital CC and CV DC Power Supply<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"356\"><a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-cc-and-cv-dc-power-supply.html\" target=\"_blank\" rel=\"noopener\">DC3005<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">4.3<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">Misuratore di potenza digitale<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"356\"><a href=\"https:\/\/www.lisungroup.com\/products\/ac-and-dc-power-supply\/digital-power-meter-ac-dc-model.html\" target=\"_blank\" rel=\"noopener\">LS2012<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"46\">4.4<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"398\">19-inch Cabinet<\/td>\n<td style=\"text-align: center; vertical-align: middle;\" width=\"356\"><a href=\"https:\/\/www.lisungroup.com\/products\/photometer-and-colorimeter\/19inch-standard-instrument-cabinet.html\" target=\"_blank\" rel=\"noopener\">CASE-19IN<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Specifiche:<br \/>\n<\/strong><strong>1.1 Photobiological UV hazard test system<\/strong><br \/>\n\u2022\u00a0 Non-cross C-T structure high-precision array spectral measurement platform;<br \/>\n\u2022\u00a0 Spectral range: 200nm~400nm;<br \/>\n\u2022\u00a0 Measurement spectrum interval: 1nm;<br \/>\n\u2022\u00a0 Wavelength accuracy: 0.2nm<br \/>\n\u2022\u00a0 Ultra-high measurement dynamic range: 100,000:1<\/p>\n<p><strong>1.2 Photobiological visible near-infrared hazard test system<\/strong><br \/>\n\u2022\u00a0 Non-cross C-T structure high-precision array spectral measurement platform;<br \/>\n\u2022\u00a0 Spectral range: 400nm~1000nm;<br \/>\n\u2022\u00a0 Measurement spectrum interval: 1nm;<br \/>\n\u2022\u00a0 Wavelength accuracy: 0.2nm<br \/>\n\u2022\u00a0 Ultra-high measurement dynamic range: 100,000:1 High measurement dynamic range: 100,000:1<\/p>\n<p><strong>1.3 Photobiological near-infrared hazard test system<\/strong><br \/>\n\u2022\u00a0 Non-cross C-T structure high-precision array spectral measurement platform;<br \/>\n\u2022\u00a0 Spectral range: 1000nm~1700nm;<br \/>\n\u2022\u00a0 Measurement spectrum interval: 1nm;<br \/>\n\u2022\u00a0 Wavelength accuracy: 0.4nm<br \/>\n\u2022\u00a0 Ultra-high measurement dynamic range: 100,000:1<\/p>\n<p><strong>1.4 Flicker test module<\/strong><br \/>\n\u2022\u00a0 Spectral range: 300nm~1100nm;<br \/>\n\u2022\u00a0 Fastest sampling speed: 100kS\/s;<\/p>\n<p><strong>2.1 Programmable two-dimensional sample rotation stage<\/strong><br \/>\n\u2022\u00a0 Maximum sample size: 150mm, 5kg<br \/>\n\u2022\u00a0 Sample rotation angle: -90\u00b0~+90\u00b0 (horizontal), -90\u00b0~+90\u00b0 (vertical)<\/p>\n<p><strong>2.2 System platform<\/strong><br \/>\n\u2022\u00a0 Program-controlled switching of measuring probes<br \/>\n\u2022\u00a0 Program-controlled adjustment of measuring distance: 10mm~200mm<\/p>\n<p><strong>3.1 UV irradiance standard source<\/strong><br \/>\n\u2022\u00a0 Spectral range: 200nm~400nm<br \/>\n\u2022\u00a0 Traceable to NIM, China National Institute of Metrology<\/p>\n<p><strong>3.2 Visible and near-infrared irradiance standard source<\/strong><br \/>\n\u2022\u00a0 Spectral range: 380nm~1650nm<br \/>\n\u2022\u00a0 Traceable to NIM, China National Institute of Metrology<\/p>\n<div id=\"attachment_17027\" class=\"wp-caption aligncenter\" style=\"width: 638px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-17027 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/05\/IEC-62115-2017-Clause-19.png\" sizes=\"(max-width: 628px) 100vw, 628px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/05\/IEC-62115-2017-Clause-19.png 628w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2025\/05\/IEC-62115-2017-Clause-19-287x400.png 287w\" alt=\"IEC 62115:2017 Clause 19\" width=\"628\" height=\"874\" aria-describedby=\"caption-attachment-17027\" title=\"\"><\/p>\n<p id=\"caption-attachment-17027\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">IEC 62115:2017 Clause 19<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The LS-IEC62115C19 Radiation and Similar Hazards Test System for Electric Toys fully complies with Clause 19 of IEC 62115. This clause specifically regulates the photobiological safety performance of light sources in toys, aiming to prevent potential hazards such as photochemical and thermal damage to children\u2019s eyes and skin caused by light sources. Targeting the core [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5132,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[677],"class_list":["post-2983","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-ls-iec62115c19"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2983","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/comments?post=2983"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/posts\/2983\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media\/5132"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/media?parent=2983"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/categories?post=2983"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/it\/wp-json\/wp\/v2\/tags?post=2983"}],"curies":[{"name":"parola chiave","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}