Introduction to Luminance Measurement in Professional Environments
Luminance measurement is a critical parameter in multiple industries, influencing product quality, safety, and compliance with international standards. The リスン LMS-6000 Luminance Meter represents a state-of-the-art solution for high-precision light measurement, designed to meet the rigorous demands of professional applications. This instrument provides accurate, repeatable, and reliable luminance data essential for research, manufacturing, and regulatory validation.
The LMS-6000 series is engineered to support diverse applications, from LED and OLED manufacturing to automotive lighting, aerospace illumination, and medical lighting equipment. Its advanced optical sensor, wide measurement range, and compliance with CIE (International Commission on Illumination) standards ensure that it delivers laboratory-grade performance in both controlled and field environments.
Technical Specifications of the LISUN LMS-6000 Luminance Meter
The LMS-6000 is a high-performance luminance meter with the following key specifications:
パラメータ | 仕様 |
---|---|
測定範囲 | 0.01 cd/m² – 300,000 cd/m² |
Spectral Response | Matches CIE Photopic Luminosity Function (V(λ)) |
正確さ | ±4% of reading (for standard illuminant A) |
Repeatability | ≤0.3% |
Field of View | 1° (configurable with optional lenses) |
Detector Type | High-sensitivity silicon photodiode |
Data Interface | USB, RS-232, Bluetooth (optional) |
Operating Temperature | 0°C – 40°C |
Compliance Standards | CIE 69, CIE 15, DIN 5032-7, JIS C 1609-1 |
The LMS-6000’s wide dynamic range and high accuracy make it suitable for both low-light applications (such as aviation panel lighting) and high-intensity measurements (such as automotive headlamps or LED displays).
Measurement Principles and Optical Design
The LMS-6000 operates on the principle of photoelectric detection, where incoming light is filtered to match the CIE standard photopic curve (V(λ)), ensuring human-eye-correlated luminance readings. The optical system consists of:
- Objective Lens System – Focuses light onto the detector while controlling the field of view (FOV).
- Spectral Correction Filter – Adjusts the sensor response to align with the CIE V(λ) function.
- High-Sensitivity Photodiode – Converts light intensity into an electrical signal with minimal noise.
- Digital Signal Processing (DSP) – Enhances measurement stability and compensates for environmental variations.
This design ensures compliance with ISO/CIE standards, making the LMS-6000 a trusted tool for scientific and industrial applications.
Industry Applications of the LMS-6000 Luminance Meter
1. LED & OLED Manufacturing
In LED and OLED production, luminance uniformity and color consistency are critical. The LMS-6000 provides precise measurements for quality control, ensuring compliance with ANSI/IES LM-79 and other industry benchmarks.
2. Automotive Lighting Testing
Automotive lighting must meet stringent regulatory standards (ECE, SAE, FMVSS). The LMS-6000 measures headlamp intensity, dashboard illumination, and signal lights with high repeatability.
3. Aerospace and Aviation Lighting
Aircraft cockpit displays and exterior navigation lights require precise luminance calibration. The LMS-6000’s low-light sensitivity ensures accurate readings for FAA and EASA compliance.
4. Display Equipment Testing
LCD, OLED, and microLED displays undergo rigorous luminance testing. The LMS-6000 evaluates brightness uniformity, contrast ratios, and viewing-angle performance.
5. Photovoltaic Industry
Solar panel testing involves measuring reflected and scattered light. The LMS-6000 assists in optimizing anti-reflective coatings and efficiency assessments.
6. Medical Lighting Equipment
Surgical and diagnostic lighting must adhere to IEC 60601-1 standards. The LMS-6000 verifies luminance levels for patient safety and procedural accuracy.
Competitive Advantages of the LMS-6000
- High Accuracy & Repeatability – Laboratory-grade precision (±4%) ensures reliable data for research and compliance.
- 広いダイナミックレンジ – Measures from ultra-low (0.01 cd/m²) to ultra-high luminance (300,000 cd/m²).
- Modular Design – Optional lenses and filters adapt the device for specialized applications.
- Regulatory Compliance – Meets CIE, DIN, JIS, and ISO standards for global acceptance.
- User-Friendly Software – Compatible with LISUN’s proprietary analysis tools for data logging and reporting.
Frequently Asked Questions (FAQ)
Q1: What is the difference between luminance and illuminance?
Luminance (cd/m²) measures the brightness of a light source as perceived by the human eye, while illuminance (lux) measures the amount of light falling on a surface.
Q2: Can the LMS-6000 measure flicker in LED lighting?
Yes, when paired with high-speed data acquisition, it can detect luminance fluctuations for flicker analysis.
Q3: Is the LMS-6000 suitable for outdoor lighting assessments?
Yes, its rugged design and wide measurement range make it ideal for urban and marine lighting evaluations.
Q4: How often should the device be calibrated?
Annual calibration is recommended to maintain accuracy, though usage conditions may necessitate more frequent checks.
Q5: Does the LMS-6000 support automated testing workflows?
Yes, it integrates with PC software for batch testing, data export, and real-time monitoring.
The LISUN LMS-6000 Luminance Meter stands as a critical instrument for industries requiring precise light measurement, combining scientific rigor with practical usability. Its adherence to international standards and adaptability across diverse applications make it an indispensable tool for professionals in lighting technology and optical research.