RF伝導イミュニティ試験システム

商品番号:

伝言を残す

=
RFCI61000-6_AL2

RF伝導イミュニティ試験システム

伝言を残す

=
製品説明

RFCI61000-6 Conducted Immunity Test System includes a built-in signal source, a power amplifier and power meter module, a variety of coupling decoupled network (CDN), electromagnetic clamp and current injection clamp developed by external attenuator by LISUN. It is widely used in medical, power, industrial control, new energy charging piles, communication piles and ect for industries.

標準:
IEC61000-4-6/EN61000-4-6 (GB/T17626.6)”Electromagnetic compatibility(EMC)- Part 4-6:Testing and measurement techniques- Immunity to conducted disturbances, induced by radio- frequency fields”
ISO11452-4 “Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy- Part 4:Harness excitation methods”

Host Configuration
出力電圧LISUN Model:RFCI61000-6-35W(Output power: 35W)1 ~ 17Vrms(CDN method)

1 ~ 11Vrms(Electromagnetic clamping method)

LISUN Model:RFCI61000-6-85W(Output power: 85W)1 ~ 30Vrms(CDN method)

1 ~ 18Vrms(Electromagnetic clamping method)

1 ~ 10Vrms(Current injection clamping method)

Output impendance50Ω
Voltage resident rate≤ 1.2
Output Frequence150kHz ~ 230MHz
Harmonic< 15dBc
Signal source (built-in)
Frequency9k ~ 1GHz
Output level-60 ~ 10dBm
Non -row signalContinuous wave
ModulationA amplitude modulation modulation frequency: 1Hz ~ 10kHz modulation depth: 1 ~ 99%

Pulse modulation and modulation frequency: 1Hz ~ 1kHz Lights ratio: 1 to 100%

Power amplifier (built-in)
Output Frequency150kHz ~ 230MHz
Max. output powerLISUN Model RFCI61000-6-35W:+44dBm/35W

LISUN Model RFCI61000-6-85W:+49dBm/85W

Harmonic< 15dBc
Power meter (built-in)
Input Frequency9kHz ~ 3GHz
Input Power-40dBm ~ +30dBm
Attenuator (built-in)
Frequency Range:DC~1GHz
Max. output power:100W
Attenuation value:6dB

Operation (please refer to GB/T17626.6 or IEC61000-4-6: 2014 Terms of Article 7.4.2 Figure 20 to select injection method: CDN method, electromagnetic clamp and current injection clamp method)):
1. The host RFCI61000-6-35W/RFCI61000-6-85W can test the power cables or communications lines with the CDN Coupling Decoupling Network (Optional) of the following models of LISUN:

RFCI61000 6 AL 2

CDN for RF Conducted Immunity Test

UPQH8RKE8J@TQ2HX4

Figure 20 – Rules for selecting the injection method

Coupling decoupling network typeLISUNモデルTest PortsVoltage / Current
Power Cables

 

CDN-M1-16Single -phase single-wire power cable220V/16A
CDN-M1-32Single -phase single-wire power cable220V/32A
CDN-M2-16Single -phase two-wire power cable220V/16A
CDN-M2-32Single -phase two-wire power cable220V/32A
CDN-M2-100Single -phase two-wire power cable220V/100A
CDN-M3-16Single -phase three-wire power cable220V/16A
CDN-M3-32Single -phase three-wire power cable220V/32A
CDN-M3-100Single -phase three-wire power cable220V/100A
CDN-M3-32-3Three -phase and three-wire power cable (3L)380V/32A
CDN-M4-32Three -phase and four-wire power cable (3L/1N)380V/32A
CDN-M4-100Three -phase and four-wire power cable (3L/1N)380V/100A
CDN-M4-32-PEThree -phase and four-wire power cable (3L/1PE)380V/32A
CDN-M5-32Three -phase and five-wire power cable (3L/1N/1PE)380V/32A
CDN-M5-100Three -phase and five-wire power cable (3L/1N/1PE)380V/100A
Non-shielding symmetrical linesCDN-T22 line100V/5A
CDN-T44 line100V/5A
CDN-T88 line100V/5A
Non -shielding non -symmetrical linesCDN-AF22 line100V/5A
CDN-AF44 line100V/5A
CDN-AF88 line100V/5A
Shield linesCDN-S82 line、4 line、8 line100V/5A
RF conduction antipitrimal coupling degraded network calibration bracketCDN-CS100Coupling decoupling network calibration bracket, which contains 150Ω-50Ω adapter resistance and If you equipped with 1 set of or more sets of CDN, you need to be equipped with at least 1 set of calibration bracket (various CDNs can equipped with it)

2. The host RFCI61000-6-35W/RFCI61000-6-85W can work with LISUN AB-EM Electromagnetic Clamp (Optional) to comply with IEC 61000-4-6. It is the immunity to conducted disturbances induced by the detection of radio frequency fields.

RFCI61000 6 AL3

Electromagnetic Clamp for RF Conducted Immunity Test

• The maximum injection power is 100W (5 minutes);
• The injection frequency is 150kHz~400MHz;
• Coupling and decoupling direction coefficient greater than 10dB>10MHz

3. The host RFCI61000-6-35W/RFCI61000-6-85W can test any signal lines with LISUN AB-100W (Optional) current injection clamp:

AB 100W AL

Current Injection Clamp for RF Conducted Immunity Test

• Support any specification signal line test: unshielded balanced line (T2, T4, T8), unshielded unbalanced line (AF2, AF4, AF8), Communication signal line (RJ11, RJ11S, RJ45, RJ45S, USB-C, USB-P) and other signal lines of any specifications
• Support maximum wire diameter: 40mm
• Maximum output power: 100W
• Frequency range: 100KHz~230MHz
• Insertion loss: <7dB
• Standard current clamp calibration parts