{"id":2332,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/temperature-humidity-chamber-thermal-chamber\/"},"modified":"2025-07-03T15:26:15","modified_gmt":"2025-07-03T07:26:15","slug":"temperature-humidity-chamber-thermal-chamber","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ja\/%e8%a3%bd%e5%93%81\/temperature-humidity-chamber-thermal-chamber\/","title":{"rendered":"IEC60068\u6e29\u6e7f\u5ea6\u74b0\u5883\u8a66\u9a13\u5668"},"content":{"rendered":"<p>Temperature Humidity Chamber | Thermal Chamber | Climate Chamber simulate different climatic conditions, such as heat-endurance, cold endurance, dryness-endurance and humidity-endurance which defines the performance of material.\u00a0 By testing the product under different climatic conditions to see whether its performance can meet the intended requirements. It is widely used to test the CFL\/LED, electricity products, automative cars, home appications and mobiles. This series of aging test chamber is suitable for the reliability test of industrial products. It has the characteristics of temperature and humidity control precision and wide control range.<\/p>\n<p><strong>\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9<\/strong>:<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/IEC60068-2-1-2007-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC60068-2-1<\/a> \u201d Environmental testing \u2013 Part 2-1: Tests \u2013 Test A: Cold\u201d<br \/>\nIEC60068-2-2 \u201cEnvironmental testing \u2013 Part 2-2: Tests \u2013 Test B: Dry heat\u201d<br \/>\nIEC60068-2-78 \u201cEnvironmental testing \u2013 Part 2-78: Tests \u2013 Test Cab: Damp heat, steady state\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IEC60598-1-2003-A1-2006-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IEC60598-1<\/a> \u300c\u7167\u660e\u5668\u5177 - \u7b2c 1 \u90e8\uff1a\u4e00\u822c\u8981\u4ef6\u304a\u3088\u3073\u8a66\u9a13<br \/>\nIES LM-80-08 \u201cApproved Method: Measuring Lumen Maintenance of LED Light \u201c<br \/>\nGB\/T2423.17 \u201cEnvironmental testing for electric and electronic products \u2013 Part 2: Test method \u2013 Test Ka: Salt mist\u201d<br \/>\nGB\/T5170.2 \u201cInspection methods for environmental testing equipment for electric and electronic products \u2014 Temperature testing equipment\u201d<br \/>\nGB\/T5170.5 \u201cInspection methods for environmental testing equipments for electric and electronic products\u2015Part 5:Damp heat testing equipments\u201d<\/p>\n<h2><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/what-is-climate-chambers.html\" target=\"_blank\" rel=\"noopener\">What is a Climate Chamber?<\/a><\/strong><\/h2>\n<p>Climate chamber is used to simulate a temperature environmental condistions. It may also be called environmental chambers or thermal chamber or temperature chamber. You can click the below videos to learn the details and also how to operate it.<\/p>\n<div class=\"video\" data-url=\"https:\/\/www.youtube.com\/embed\/n0A7CEFHmGc?autoplay=1\"><i class=\"video_play fa\"><\/i> <img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" title=\"Thermal Chamber | Temperature Humidity Chamber | Climate Chamber - LISUN\" src=\"https:\/\/i.ytimg.com\/vi\/n0A7CEFHmGc\/sddefault.jpg\" alt=\"\u30d3\u30c7\u30aa\" width=\"640\" height=\"480\" \/><\/div>\n<p><strong>\u4ed5\u69d8\uff1a<br \/>\n<\/strong>\u2022 The temperature humidity test chamber is made of SUS304 Steel. The thermal insulation layer is made of polyurethane hard foam ultra-fine glass fiber. The heat-insulated doorframe uses high temperature aging silicone rubber sealing strip.<br \/>\n\u2022 The temperature controller of the climate chamber includes Korean TEMI display in English\/Chinese and German Siemens PLC. It can communicate with PC via RS-232. The temperature accuracy is 0.1\u2103 and humidity accuracy is 0.1%R.H.<br \/>\n\u2022 The temperature sensor is platinum PT100\u03a9\/MV.<br \/>\n\u2022 The independant heating system uses nickel-chrome electric heater.<br \/>\n\u2022 The refrigerating system is fully enclosed air-cooled single-stage compression refrigeration mode, and the compressor is from France TECUMSEH brand which can allow you get after sales support from many other countries.<br \/>\n\u2022 The circulation system uses temperature resistant and low noise air-conditioned motor and multi-blade centrifugal wind wheel.<br \/>\n\u2022 The safety protection system includes electric leakage, short circuit, over temperature, motor overheating, compressor pressure, overload, over-current protection.<br \/>\n\u2022 Working Voltage: AC380V\u00b110% 3 phases and frequency 50Hz\/60Hz<br \/>\n\u2022 Working Environmental: Temperature 5\u2103\uff5e+30\u2103 and Humidity \u226485%R.H<\/p>\n<div>\n<table style=\"width: 100.563%; height: 341px;\" width=\"802\">\n<tbody>\n<tr style=\"height: 31px;\">\n<td style=\"width: 97.8372%; vertical-align: middle; text-align: left; height: 31px;\" colspan=\"7\" width=\"802\"><strong>High &amp; Low Temperature Humidity Chamber with Programmable Function (GDJS Series)<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 20.4835%;\" width=\"184\">LISUN\u30e2\u30c7\u30eb<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 15.0127%;\" width=\"103\">GDJS-100*<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.5954%;\" width=\"103\">GDJS-225*<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 11.8321%;\" width=\"103\">GDJS-500*<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.5954%;\" width=\"103\">GDJS-010*<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.4682%;\" width=\"103\">GDJS-015*<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.8499%;\" width=\"103\">GDJS-020*<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 20.4835%;\" width=\"184\">Workroom Dimensions<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 15.0127%;\" width=\"103\">41*55*45<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.5954%;\" width=\"103\">50*60*75<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 11.8321%;\" width=\"103\">70*80*90<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.5954%;\" width=\"103\">100*100*100<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.4682%;\" width=\"103\">100*100*150<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.8499%;\" width=\"103\">100*100*200<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 20.4835%;\" width=\"184\">External Dimensions<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 15.0127%;\" width=\"103\">105*105*156<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.5954%;\" width=\"103\">105*102*200<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 11.8321%;\" width=\"103\">132*132*217<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.5954%;\" width=\"103\">167*152*231<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.4682%;\" width=\"103\">245*160*231<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.8499%;\" width=\"103\">160*254*214<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 20.4835%;\" width=\"184\">\u4f5c\u696d\u30d1\u30ef\u30fc<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 15.0127%;\" width=\"103\">5.5kW<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.5954%;\" width=\"103\">7.0kW<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 11.8321%;\" width=\"103\">13.5kW<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.5954%;\" width=\"103\">15.0kW<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.4682%;\" width=\"103\">16.5kW<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 12.8499%;\" width=\"103\">26.5kW<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 20.4835%;\" width=\"184\">Temperature Range<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 77.3537%;\" colspan=\"6\" width=\"618\">A: -20\u2103~150\u2103 \u00a0 \u00a0 \u00a0B: -40\u2103~150\u2103 \u00a0 \u00a0 C: -60\u2103~150\u2103\u00a0 \u00a0 D: -70\u2103~150\u2103<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 20.4835%;\" width=\"184\">Fluctuation\/Evenness<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 15.0127%;\" width=\"618\">\u00b10.5\u2103\/\u00b12\u2103<\/td>\n<td style=\"width: 12.5954%;\"><\/td>\n<td style=\"width: 11.8321%;\"><\/td>\n<td style=\"width: 12.5954%;\"><\/td>\n<td style=\"width: 12.4682%;\"><\/td>\n<td style=\"width: 12.8499%;\"><\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 20.4835%;\" width=\"184\">Temperature Rise Speed<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 77.3537%;\" colspan=\"6\" width=\"618\">1.0\u2103~3.0\u2103\/min<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 20.4835%;\" width=\"184\">Temperature Fall Speed<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 77.3537%;\" colspan=\"6\" width=\"618\">0.7\u2103~1.0\u2103\/min<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 20.4835%;\" width=\"184\">\u6e7f\u5ea6\u7bc4\u56f2<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 77.3537%;\" colspan=\"6\" width=\"618\">20%~98% R.H<\/td>\n<\/tr>\n<tr style=\"height: 31px;\">\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 20.4835%;\" width=\"184\">\u6e7f\u5ea6\u504f\u5dee<\/td>\n<td style=\"text-align: left; height: 31px; vertical-align: middle; width: 77.3537%;\" colspan=\"6\" width=\"618\">-2%~-3% R.H<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"width: 100.779%; height: 286px;\" width=\"762\">\n<tbody>\n<tr>\n<td style=\"width: 97.4968%; text-align: left; vertical-align: middle;\" colspan=\"7\" width=\"762\"><strong>High and Low Temperature Chamber with Programmable Function (GDJW Series)<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.3202%; text-align: left; vertical-align: middle;\" width=\"186\">LISUN\u30e2\u30c7\u30eb<\/td>\n<td style=\"width: 12.097%; text-align: left; vertical-align: middle;\" width=\"96\">GDJW-100*<\/td>\n<td style=\"width: 11.9798%; text-align: left; vertical-align: middle;\" width=\"96\">GDJW-225*<\/td>\n<td style=\"width: 12.2384%; text-align: left; vertical-align: middle;\" width=\"96\">GDJW-500*<\/td>\n<td style=\"width: 13.0483%; text-align: left; vertical-align: middle;\" width=\"96\">GDJW-010*<\/td>\n<td style=\"width: 12.5359%; text-align: left; vertical-align: middle;\" width=\"96\">GDJW-015*<\/td>\n<td style=\"width: 12.2772%; text-align: left; vertical-align: middle;\" width=\"96\">GDJW-020*<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.3202%; text-align: left; vertical-align: middle;\" width=\"186\">Workroom Dimensions (cm)<\/td>\n<td style=\"width: 12.097%; text-align: left; vertical-align: middle;\" width=\"96\">41*55*45<\/td>\n<td style=\"width: 11.9798%; text-align: left; vertical-align: middle;\" width=\"96\">50*60*75<\/td>\n<td style=\"width: 12.2384%; text-align: left; vertical-align: middle;\" width=\"96\">70*80*90<\/td>\n<td style=\"width: 13.0483%; text-align: left; vertical-align: middle;\" width=\"96\">100*100*100<\/td>\n<td style=\"width: 12.5359%; text-align: left; vertical-align: middle;\" width=\"96\">100*100*150<\/td>\n<td style=\"width: 12.2772%; text-align: left; vertical-align: middle;\" width=\"96\">100*100*200<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.3202%; text-align: left; vertical-align: middle;\" width=\"186\">Temperature Range<\/td>\n<td style=\"width: 74.1766%; text-align: left; vertical-align: middle;\" colspan=\"6\" width=\"576\">\u00a0A: -20\u2103~150\u2103 \u00a0 \u00a0 \u00a0B: -40\u2103~150\u2103 \u00a0 \u00a0 C: -60\u2103~150\u2103\u00a0 \u00a0 D: -70\u2103~150\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.3202%; text-align: left; vertical-align: middle;\" width=\"186\">Fluctuation\/Evenness<\/td>\n<td style=\"width: 74.1766%; text-align: left; vertical-align: middle;\" colspan=\"6\" width=\"576\">\u00b10.5\u2103\/\u00b12\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.3202%; text-align: left; vertical-align: middle;\" width=\"186\">Temperature Rise Speed<\/td>\n<td style=\"width: 74.1766%; text-align: left; vertical-align: middle;\" colspan=\"6\" width=\"576\">1.0\u2103~3.0\u2103\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 23.3202%; text-align: left; vertical-align: middle;\" width=\"186\">Temperature Fall Speed<\/td>\n<td style=\"width: 74.1766%; text-align: left; vertical-align: middle;\" colspan=\"6\" width=\"576\">0.7\u2103~1.0\u2103\/min<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"width: 100.952%; height: 212px;\" width=\"762\">\n<tbody>\n<tr>\n<td style=\"text-align: left; vertical-align: middle; width: 97.9721%;\" colspan=\"6\" width=\"762\"><strong>High Temperature Chamber\/Oven Chamber\/Aging Oven Testing (GW Series)<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left; vertical-align: middle; width: 26.3625%;\" width=\"186\">LISUN\u30e2\u30c7\u30eb<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 14.0684%;\" width=\"96\">GW-225<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 14.0684%;\" width=\"96\">GW-500<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 14.7022%;\" width=\"96\">GW-010<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 14.5754%;\" width=\"96\">GW-015<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 14.1952%;\" width=\"96\">GW-020<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left; vertical-align: middle; width: 26.3625%;\" width=\"186\">Workroom Dimensions (cm)<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 14.0684%;\" width=\"96\">50*60*75<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 14.0684%;\" width=\"96\">70*80*90<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 14.7022%;\" width=\"96\">100*100*100<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 14.5754%;\" width=\"96\">100*100*150<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 14.1952%;\" width=\"96\">100*100*200<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left; vertical-align: middle; width: 26.3625%;\" width=\"186\">Temperature Range<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 71.6096%;\" colspan=\"5\" width=\"576\">Enviromental Temperature ~250\u2103 (Option to 300\u2103)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left; vertical-align: middle; width: 26.3625%;\" width=\"186\">Fluctuation\/Evenness<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 71.6096%;\" colspan=\"5\" width=\"576\">\u00b10.5\u2103\/\u00b12\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left; vertical-align: middle; width: 26.3625%;\" width=\"186\">Temperature Rise Speed<\/td>\n<td style=\"text-align: left; vertical-align: middle; width: 71.6096%;\" colspan=\"5\" width=\"576\">1.0\u2103~3.0\u2103\/min<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div>\n<p><strong>The * in GDJS-225*\/GDJW-225* means the temperature range A: -20\u2103-150\u2103, B: -40\u2103-150\u2103,\u00a0 C: -60\u2103-150\u2103\uff0cD: -70\u2103-150\u2103<br \/>\n<\/strong><\/p>\n<h2><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/how-does-a-humidity-chamber-work.html\" target=\"_blank\" rel=\"noopener\">How does an environmental chamber work?<\/a><\/strong><\/h2>\n<p>The temperature and humidity environmental chamber can simulate a variety of temperature and humidity natural environments, and is suitable for testing electronic devices, household appliances, food, trolleys, vulcanized rubber, plastic rubber, metal materials and other commodities. The whole process of humidification of the temperature and humidity\u00a0<strong>environmental chamber<\/strong>\u00a0is to increase the working pressure of water vapor. The more initial way is to spray water on the test box wall to control the saturation pressure of the water surface according to the operating temperature.<\/p>\n<h2><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/high-low-temperature-humidity-test-chamber-analysis-in-china-market.html\" target=\"_blank\" rel=\"noopener\">What\u2019s <\/a><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/high-low-temperature-humidity-test-chamber-analysis-in-china-market.html\" target=\"_blank\" rel=\"noopener\">Temperature Chamber <\/a><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/high-low-temperature-humidity-test-chamber-analysis-in-china-market.html\" target=\"_blank\" rel=\"noopener\">quality difference between LISUN and other brands in China Market?<\/a><\/strong><\/h2>\n<p>1. LISUN low temperature such as -60\u2103 warranty under a 200W lamps with heating but other brands under empty conditions.<br \/>\n2. LISUN adopts with Finland brand electronic humidity sensor which no need to maintenence. But our competitor used dry ball device which is easy dry to cause problems after used 3-6months.<br \/>\n3. LISUN equipped a water purification device, customer can use a water pipe connect it to provide water supply directly, our competitor but need to add the water by hand.<br \/>\n4. LISUN temperature chamber key electrical connector parts adopted with famous brand AC contactor and solid state relays from Schneider and Omron brands. It is easy for you to find in your local market if they were failed, but our competitors used them with almost Chinese local brands.<\/p>\n<div id=\"attachment_6142\" class=\"wp-caption aligncenter\" style=\"width: 297px;\">\n<p><img decoding=\"async\" class=\"wp-image-6142\" title=\"Thermal Chamber\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GDJS_AL5-400x400.jpg\" sizes=\"(max-width: 287px) 100vw, 287px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GDJS_AL5-400x400.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GDJS_AL5-100x100.jpg 100w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GDJS_AL5-768x768.jpg 768w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GDJS_AL5-1080x1080.jpg 1080w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GDJS_AL5.jpg 1200w\" alt=\"High and Low Temperature Humidity Chamber GDJS AL5\" width=\"287\" height=\"287\" aria-describedby=\"caption-attachment-6142\" \/><\/p>\n<p id=\"caption-attachment-6142\" class=\"wp-caption-text\">Temperature Humidity Chamber Test Curve<\/p>\n<\/div>\n<p>Appendix: GDJS Series Temperature and Humidity Corresponding Chart (Note: This is a regular model. If you have special requirements, please contact us for customization):<\/p>\n<div id=\"attachment_13446\" class=\"wp-caption aligncenter\" style=\"width: 766px;\">\n<p><img decoding=\"async\" class=\"wp-image-13446 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GDJS-Temperature-And-Humidity-Corresponding-Chart.jpg\" sizes=\"(max-width: 756px) 100vw, 756px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GDJS-Temperature-And-Humidity-Corresponding-Chart.jpg 756w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/GDJS-Temperature-And-Humidity-Corresponding-Chart-400x235.jpg 400w\" alt=\"GDJS Series Temperature And Humidity Corresponding Chart\" width=\"756\" height=\"444\" aria-describedby=\"caption-attachment-13446\" title=\"\"><\/p>\n<p id=\"caption-attachment-13446\" class=\"wp-caption-text\">GDJS Series Temperature And Humidity Corresponding Chart<\/p>\n<\/div>\n<\/div>\n<p><strong><a href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-gdjs-015b-temperature-humidity-chamber-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #0000ff;\">LISUN GDJS-015B Temperature Humidity Chamber \u2013 After-sales Frequently Asked Questions (FAQ)<\/span><\/a><br \/>\n<\/strong>LISUN GDJS-015B Temperature Humidity Chamber were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>Temperature Humidity Chamber | Thermal Chamber | Climate Chamber simulate different climatic conditions, such as heat-endurance, cold endurance, dryness-endurance and humidity-endurance which defines the performance of material.\u00a0 By testing the product under different climatic conditions to see whether its performance can meet the intended requirements. It is widely used to test the CFL\/LED, electricity products, automative cars, home appications and mobiles. This series of aging test chamber is suitable for the reliability test of industrial products. It has the characteristics of temperature and humidity control precision and wide control range. Standard: IEC60068-2-1 \u201d Environmental testing \u2013 Part 2-1: Tests \u2013 Test A: Cold\u201d IEC60068-2-2 \u201cEnvironmental testing \u2013 Part 2-2: Tests [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4771,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[90],"class_list":["post-2332","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-gdjs-015b"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/comments?post=2332"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2332\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media\/4771"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media?parent=2332"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/categories?post=2332"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/tags?post=2332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}