{"id":2343,"date":"2025-06-19T19:34:49","date_gmt":"2025-06-19T11:34:49","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/rotation-luminaire-goniophotometer\/"},"modified":"2025-06-27T10:41:32","modified_gmt":"2025-06-27T02:41:32","slug":"%e5%9b%9e%e8%bb%a2%e7%81%af%e3%82%b4%e3%83%8b%e3%82%aa%e3%83%95%e3%82%a9%e3%83%88%e3%83%a1%e3%83%bc%e3%82%bf%e3%83%bc","status":"publish","type":"post","link":"https:\/\/www.ledphotometer.com\/ja\/%e8%a3%bd%e5%93%81\/%e5%9b%9e%e8%bb%a2%e7%81%af%e3%82%b4%e3%83%8b%e3%82%aa%e3%83%95%e3%82%a9%e3%83%88%e3%83%a1%e3%83%bc%e3%82%bf%e3%83%bc\/","title":{"rendered":"\u56de\u8ee2\u706f\u30b4\u30cb\u30aa\u30d5\u30a9\u30c8\u30e1\u30fc\u30bf\u30fc"},"content":{"rendered":"<p>LSG-1700 <a href=\"https:\/\/www.lisungroup.com\/products\/goniophotometer\/\" target=\"_blank\" rel=\"noopener\">\u30b4\u30cb\u30aa\u30d5\u30a9\u30c8\u30e1\u30fc\u30bf\u30fc<\/a> is an automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source. It is for industrial laboratory photometric data measurement of luminaires such as LED luminaires, HID luminaires, fluorescent lamps and so on.<\/p>\n<div id=\"attachment_6255\" class=\"wp-caption aligncenter\" style=\"width: 1930px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-6255 size-large\" title=\"IES FILE TESTING GONIOPHOTOMETER\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-1890B_YK6-1920x569.jpg\" sizes=\"(max-width: 1920px) 100vw, 1920px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-1890B_YK6-1920x569.jpg 1920w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-1890B_YK6-400x119.jpg 400w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/LSG-1890B_YK6-768x228.jpg 768w\" alt=\"\u9ad8\u7cbe\u5ea6\u56de\u8ee2\u5f0f\u30b4\u30cb\u30aa\u30d5\u30a9\u30c8\u30e1\u30fc\u30bf LSG 1890B YK6\" width=\"1920\" height=\"569\" aria-describedby=\"caption-attachment-6255\" \/><\/p>\n<p id=\"caption-attachment-6255\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">\u56de\u8ee2\u706f\u30b4\u30cb\u30aa\u30d5\u30a9\u30c8\u30e1\u30fc\u30bf\u30fc<\/span><\/p>\n<\/div>\n<p><strong>\u6a19\u6e96\uff1a<br \/>\n<\/strong><a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">LM-79-19<\/a> \u300c\u56fa\u4f53\u7167\u660e\u88fd\u54c1\u306e\u5149\u5b66\u7684\u304a\u3088\u3073\u96fb\u6c17\u7684\u6e2c\u5b9a\u300d<br \/>\n<a href=\"https:\/\/www.lisungroup.cn\/wp-content\/uploads\/2019\/07\/EN13032-1-2004AC-2005.pdf\" target=\"_blank\" rel=\"noopener\">EN13032-1<\/a> \u300c\u5149\u3068\u7167\u660e \u2013 \u30e9\u30f3\u30d7\u304a\u3088\u3073\u7167\u660e\u5668\u5177\u306e\u5149\u6e2c\u5b9a\u30c7\u30fc\u30bf\u306e\u6e2c\u5b9a\u304a\u3088\u3073\u8868\u793a \u2013 \u30d1\u30fc\u30c81\uff1a\u6e2c\u5b9a\u304a\u3088\u3073\u30d5\u30a1\u30a4\u30eb\u5f62\u5f0f\uff1b\u30c9\u30a4\u30c4\u8a9e\u7248 EN 13032-1:2004+A1:2012\u300d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IES-LM-80-2011-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-80-08<\/a> \"LED\u5149\u6e90\u306e\u30eb\u30fc\u30e1\u30f3\u7dad\u6301\u7387\u306e\u6e2c\u5b9a\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/CIE-121-1996-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-121<\/a> \u201c\u300c\u7167\u660e\u5668\u5177\u306e\u6e2c\u5149\u3068\u5909\u89d2\u6e2c\u5149\u300d\u201d<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-70-1987-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-70\u00a0 \u201c<\/a>\u7d76\u5bfe\u5149\u5ea6\u5206\u5e03\u306e\u6e2c\u5b9a\"<br \/>\n<a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESNA_LM-75-2001-Goniophotometer-Types-and-Photometric-Coordinates.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-75<\/a>\u00a0 \u300c\u30b4\u30cb\u30d5\u30a9\u30c8\u30e1\u30fc\u30bf\u30fc\u306e\u7a2e\u985e\u3068\u6e2c\u5149\u5ea7\u6a19\"<strong><br \/>\n<\/strong><\/p>\n<h2><strong>IES file testing Goniophotometer Specification:<\/strong><\/h2>\n<p>\u2022 Meets the requirements of <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2020\/02\/CIE-70-1987-Standard-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">CIE-70<\/a>, IEC, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/06\/lm-79-19.pdf\" target=\"_blank\" rel=\"noopener\">IES LM-79<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/IESLM-79-LM-80-Chinese-Version-Free-Download.pdf\" target=\"_blank\" rel=\"noopener\">LM-80<\/a>, <a href=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2019\/07\/EN13032-1-2004AC-2005.pdf\" target=\"_blank\" rel=\"noopener\">EN13032-1<\/a> &amp; GB standards<br \/>\n\u2022 Reaching many measurement ways C-Gamma<br \/>\n\u2022 The luminaries under test rotates around an angle of (\u03b3)\u00b1180\u00b0(or 0-360\u00b0) and the luminaries rotates around itself with an angle of (C)\u00b1180\u00b0(or 0-360\u00b0)<br \/>\n\u2022 Luminosity testing range: Illuminance 0.001lx~10,000lx; Light Intensity 1.0cd\uff5e10^7cd (detector)<br \/>\n\u2022 The accuracy of angle: 0.2\u00b0<br \/>\n\u2022 Photometry accuracy: CIE Class 1<br \/>\n\u2022 Testing accuracy: 3%(Under Standard lamp); Stray Light: less than 0.2%<br \/>\n\u2022 English version software can run on Win7, Win8 or Win10, Win11<\/p>\n<table style=\"height: 116px; width: 99.8267%;\" border=\"1\" width=\"762\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr style=\"height: 23px;\">\n<td style=\"height: 70px; width: 17.7792%;\" rowspan=\"2\">LISUN\u30e2\u30c7\u30eb<\/td>\n<td style=\"height: 23px; width: 65.5383%;\" colspan=\"2\">The max size of the Luminaires Under Test<\/td>\n<td style=\"height: 70px; width: 35.5882%;\" rowspan=\"2\">\u6700\u5927\u91cd\u91cf<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"height: 47px; width: 33.557%;\">C-Gamma Test with one Pillar<\/td>\n<td style=\"height: 47px; width: 31.9813%;\">B-Beta Test with Two Pillars<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"height: 23px; width: 17.7792%;\">LSG-1700<\/td>\n<td style=\"height: 23px; width: 33.557%;\">\u03a61600*550 (Dia*Depth)<\/td>\n<td style=\"height: 23px; width: 31.9813%;\">\u8a72\u5f53\u306a\u3057<\/td>\n<td style=\"height: 23px; width: 35.5882%;\">40kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.lisungroup.com\/news\/technology-news\/lisun-lsg-1700-rotation-luminaire-goniophotometer-after-sales-questions-and-answers.html\" target=\"_blank\" rel=\"noopener\">LISUN LSG-1700 Rotation Luminaire Goniophotometer \u2013 After-sales Frequently Asked Questions (FAQ)<\/a><\/span><br \/>\n<\/strong>LISUN LSG-1700 Rotation Luminaire Goniophotometer were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.<\/p>","protected":false},"excerpt":{"rendered":"<p>LSG-1700 goniophotometer is an automatic goniophotometric instrument for luminous intensity distribution measurement with facility for rotating the light source. It is for industrial laboratory photometric data measurement of luminaires such as LED luminaires, HID luminaires, fluorescent lamps and so on. Rotation Luminaire Goniophotometer Standard: LM-79-19 \u201cOptical and Electrical Measurements of Solid State Lighting Products\u201d EN13032-1 \u201cLight and lighting \u2013 Measurement and presentation of photometric data of lamps and luminaires \u2013 Part 1: Measurement and file format; German version EN 13032-1:2004+A1:2012\u201d IES LM-80-08 \u201cMeasuring Lumen Maintenance of LED Light Sources\u201d CIE-121 \u201cThe Photometry and Goniophotometry of Luminaires\u201d CIE-70\u00a0 \u201cThe Measurement of Absolute Luminous Intensity Distribution\u201d IES LM-75\u00a0 \u201cGoniophotometerTypes and Photometric Coordinates\u201d [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3501,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[101],"class_list":["post-2343","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-lsg-1700"],"_links":{"self":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2343","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/comments?post=2343"}],"version-history":[{"count":0,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/posts\/2343\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media\/3501"}],"wp:attachment":[{"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/media?parent=2343"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/categories?post=2343"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ledphotometer.com\/ja\/wp-json\/wp\/v2\/tags?post=2343"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}